Siemens 6ES7157-0AC83-0XA0 SIMATIC DP/PA Coupler FDC 157-0

Nomen producti: SIMATIC DP/PA Coupler FDC 157-0
Nomen Marcae: Siemens
Numerus Modeli: 6ES7157-0AC83-0XA0
Locus Originis: Germania
Garantia: 12 Mensis
Whatsapp: +86 18020776782
Inscriptio electronica: [email protected]
Appurtenance
  • Conspectus
  • DESCRIPTIO
  • Redundant PA Design
  • Specificationes
  • Installatio et servitium
  • Commercial Term
  • INFORMATIO CONTACTUS
  • Quaestiones Frequentes
  • Other Products
  • Producta commendata
Redundancy-capable PROFIBUS DP-to-PA fieldbus coupler with integrated segment power and diagnostics
The FDC 157-0 converts the RS485 PROFIBUS DP physical layer at 45.45 kbit/s to PROFIBUS PA at 31.25 kbit/s. It electrically isolates the networks, supplies the PA segment, supports a 1 A PA load and can provide local diagnostics, ring redundancy or coupler redundancy.
Fieldbus topology check: Confirm stand-alone or DP/PA Link use, diagnostic address, PA segment current, termination, non-redundant or redundant bus module, ACT LED state and 24 V supply arrangement before replacing or expanding the installation.

DESCRIPTIO

6ES7157-0AC83-0XA0 is the Siemens FDC 157-0 for linking PROFIBUS DP and PROFIBUS PA. With address 0, the coupler operates transparently and can replace 6ES7157-0AC82-0XA0 without configuration; diagnostics require the same nonzero address in the hardware configuration and at the DIL switches.
A redundant pair must use the BM FDC/FDC bus module and the correct RING setting. Before disturbing a live redundant segment, verify that the ACT LED on the coupler being removed is off, isolate its 24 V DC supply and preserve the PA termination and cable routing.

Redundant PA Design

The redundancy mode, bus module and segment termination must agree; a working pair can still be misconfigured at the DIL switches.
Ring Redundancy
Use the BM FDC/FDC bus module with two FDC 157-0 couplers, set RING ON and document the active field-distributor ring.
Coupler redundancy
Use the same redundant bus module with RING OFF and preserve the AFS or center-feed topology and PA termination.
Live replacement
Remove only the inactive coupler, confirm ACT is off, disconnect its 24 V supply and then exchange the module.

Specificationes

Designatio generis producti SIMATIC DP/PA Coupler FDC 157-0
Numerus ordinis 6ES7157-0AC83-0XA0
Velocitas PROFIBUS DP 45,45 kbit/s
Velocitas PROFIBUS PA 31,25 kbit/s
PA output 31 V DC +/-1 V; maximum 1 A segment current
DP address 1 usque ad 125 per interruptorem DIL; 0 disactivat functiones diagnosticas
Supple voltage 24 V DC, 20.4 ad 28.8 V
Consumptio potentiae Maximum 2.3 A ad 24 V DC
Ammissio Potentiae Maximum 13.4 W
Diagnosis LED SF, BF, DP, PA, ACT et ON; DP tenet records diagnosticos
Dimensiones / Pondus 80 x 125 x 130 mm; circa 515 g
Capacitas dispositivi PA Usque ad 31 dispositiva campi PA intra limitem currentis 1 A

Installatio et servitium

  • Constitue potestatem, adressem, connexionem PA et functiones diagnosticas in ordine regulato, ut defectus segmenti non confundatur cum accoplatore vitioso.
    Potestas et connexio ad terram
    Use a safely isolated SELV supply; in an ungrounded system use separate isolated 24 V supplies when electrical isolation must be retained.
    Address and mode
    Match the PROFIBUS address in the project and DIL switches, then select the required redundancy mode before applying power.
    Segment evidence
    Record PA current, terminator position, field-device count, BF or SF indications and the local LifeList before changing wiring.

Commercial Term

  • Praeoffertio
    Pretium praesens et disponibilitas
    Solutio
    T/T aut condicionibus conventis
    Tempus praecedens
    Confirmatum cum citatione
    Navigatio
    DHL, FedEx, UPS aut oneribus conventis
    Garantia
    12 Mensis

INFORMATIO CONTACTUS

Quaestiones Frequentes

Q1
How can I confirm that 6ES7157-0AC83-0XA0 will replace the installed DP/PA coupler correctly?
Check the complete order number, bus module, stand-alone or DP/PA Link arrangement, PROFIBUS address, PA termination and redundancy mode. It can replace 6ES7157-0AC82-0XA0 transparently at address 0, but diagnostic or redundant operation requires project and switch settings.
Q2
What should I check before removing 6ES7157-0AC83-0XA0 from a redundant PA segment?
Verificare che il LED ACT sul coupler da rimuovere non sia acceso, confermare che il coupler partner sia funzionante e scollegare il coupler selezionato dall’alimentazione a 24 V CC. Etichettare le posizioni PA, DP e bus-module prima di spostare qualsiasi connessione.
Q3
Perché il modello 6ES7157-0AC83-0XA0 può mostrare un guasto PROFIBUS DP dopo l’installazione?
Confrontare l’indirizzo configurato con l’indirizzo impostato tramite interruttori DIL e confermare che il master DP utilizzi 45,45 kbit/s. Verificare quindi il connettore DP, la terminazione del cavo, la modalità di ridondanza selezionata e se la diagnostica sia stata abilitata intenzionalmente con un indirizzo superiore a 0.
Q4
Perché il LED PA o il LED SF possono indicare un guasto sul modello 6ES7157-0AC83-0XA0?
Misurare il carico e la tensione del segmento PA, confermare che la corrente totale dei dispositivi di campo rimanga entro 1 A, ispezionare la presenza di cortocircuiti o interruzioni del filo e verificare che entrambi i terminatori siano presenti. Leggere la LifeList locale e il registro diagnostico prima di scollegare i dispositivi.
Q5
Come alimentare il modello 6ES7157-0AC83-0XA0 in un’installazione non collegata a terra?
Use an approved SELV 24 V DC supply and review the plant grounding concept. If an IM 153-2 and the coupler share one supply, electrical isolation can be cancelled; use two electrically isolated supplies where the isolation must be preserved.
Q6
What must be preserved when commissioning a replacement 6ES7157-0AC83-0XA0?
Record the former address, RING setting, bus-module type, ACT state, PA terminator position, segment current, connected field devices and diagnostic messages. Restore these items first, then verify DP communication, PA voltage and redundancy behavior.

Other Products

TMPU-750 17-505750-001
15993030
212.11UOS
2CDG110079R0011
PXC50-ED S55372-C110
MQSE-4S1-D
RO8-1.4 C29F
902 J/K PT100 ICP11J0450000
EVD0000T41
BLU300M-001
LEGRAND 002640
COBALT 6590
STBPDT3100
517-0147-04C 04-21-956029
VM-114H 2XINPUT
El-805u-d-868-500m
7000-5234-1, 4000-4175-2
9377-FB
RLED-CR
Wrt-822B
805u-d El-805u-d-868-500m
AUD50A100D 1636F
4TKNX IP20
TVAC10100
9377FB
JMG 4TKNX IP20
MP204
V130-J-R34
PT100 ICP11J0450000
1GK-00006