| Modellum | 3624 |
| Genus moduli | Supervisata TMR digitalis outputus |
| Puncta Exirentia | 16 |
| Communio output | Communis |
| Nominal Output Voltage | 24 V DC |
| Operans voltage range | 16 ad 30 V DC |
| Tensio applicata maxima | 36 V DC |
| Decrementum voltatis exsurgentis | Minus quam 1.5 V DC typice |
| Moduli potestas oneris | Minus quam 10 W |
| Maxima Currentis Onus | 0,7 A per punctum |
| Assurgat current | 4.8 A pro 10 ms |
| Minimum supervisatum onus | 30 mA |
| Current Leakage | 4 mA maximum |
| Tutela Exitus | Sese Protegens |
| Exigentia Fusibilis Externi | Non opus est |
| Isolatio Puncti | 1500 V DC |
| Indicatio Status Output | Unus indicativus pro singulo puncto |
| Indicatores status moduli | PASS, FAULT et ACTIVE |
| Indikatoria campi | POWER et LOAD per punctum |
| Module Color Code | Viridis turquesa |
| Output Architecture | Logica controlis triplicata supervisa |
| Familia ETP compatibilis | 9662-610F et tabulae correlatae 24 V DC |
| Minimum quantitas ordinis | 1 piece |
| Pretium | Contactus pro Jim |
| Singula Packaging | Novus Originalis, Sigillatus a Fabrica |
| Tempus Traditionis | 3–7 dies |
| Condiciones solutionis | T/T |
| Shipping modum | DHL / FedEx / UPS / TNT |
| Capacitas Supplicandi | Novus prorsus, in stock |
3624est modulus Triconex Tricon supervisus TMR digitalis output cum sedecim punctis 24 V DC communibus. Intervalum operativum est 16 ad 30 V DC, et unumquodque canale praebere potest usque ad 0.7 A. Onus supervisum minimi 30 mA permittit modulo monitorare continuitatem circuitus campi.
Logica controlis triplicata determinat statum output mandatum dum modulus supervidet viam campi 24 V DC communem et onera individualia. Unumquodque punctum se protegit, itaque fusibilis externus canalium non requiritur. Indikatoria POWER et LOAD complent display statuum per punctum et indikatoria moduli PASS, FAULT et ACTIVE.
The 3624 must be connected to a compatible commoned termination panel and correctly sized field loads. Unused or very low-current channels can affect supervision behavior and should be handled in line with the termination design. Supply limits, common return wiring and safe-state logic require validation before startup.
| pdrc816FR-knx | MX420/2 350810270200 | C2Enet-1 |
| CPO-RL4 | MB3170 | EGX100MG |
| IO-351-A 96161720-V01 | CES-A-UEA-04B 097075 | M100-RTD |
| EB401 EB401-10 | ED-SxED 22176716 | SB522A |
| MC350-4T-2S | Q.PS-AD2-2402F | C-9402 |
| PS00B02KNX | SensION1 5170060 | SB-DIM4c3A-DN |
| RS20-0800T1T1SDAPHH05.0.02 | TMT112-AAAAA | E080-04 |
| X87-813 | TCSESM043F23F0 | cPCI-R3610T |
| CCHE-CP24-D3-P003CH | PCO3000AM0 | IG6614 |
| SK41-32 | RXV-35-4K/4K | edmk-itf-c2 |
| TST8804 | FX03 / LP-FX03A11-0C | CLTG38EXPN01 |
| AC2257 | EPX420D | msv930 |
| CLIOP821A | ID22W00TCH300 | M19D902781G3 |