| Model | 3624 |
| Module type | Supervised TMR digital output |
| Output points | 16 |
| Output commoning | Commoned |
| Nominal output voltage | 24 V DC |
| Operating voltage range | 16 to 30 V DC |
| Maximum applied voltage | 36 V DC |
| Output voltage drop | Less than 1.5 V DC typical |
| Module load power | Less than 10 W |
| Maximum load current | 0.7 A per point |
| Surge current | 4.8 A for 10 ms |
| Minimum supervised load | 30 mA |
| Leakage current | 4 mA maximum |
| Output protection | Self-protecting |
| External fuse requirement | Not required |
| Point isolation | 1500 V DC |
| Output status indication | One indicator per point |
| Module status indicators | PASS, FAULT and ACTIVE |
| Field indicators | POWER and LOAD per point |
| Module color code | Turquoise green |
| Output architecture | Triplicated supervised control |
| Compatible ETP family | 9662-610F and related 24 V DC panels |
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
3624 is a Triconex Tricon supervised TMR digital output module with sixteen commoned 24 V DC points. The operating range is 16 to 30 V DC, and each channel can supply up to 0.7 A. A supervised load of at least 30 mA allows the module to monitor field-circuit continuity.
Triplicated control logic determines the commanded output state while the module supervises the shared 24 V DC field path and individual loads. Each point is self-protecting, so an external channel fuse is not required. POWER and LOAD indicators complement the per-point state display and the PASS, FAULT and ACTIVE module indicators.
The 3624 must be connected to a compatible commoned termination panel and correctly sized field loads. Unused or very low-current channels can affect supervision behavior and should be handled in line with the termination design. Supply limits, common return wiring and safe-state logic require validation before startup.
| pdrc816FR-knx | MX420/2 350810270200 | C2ENET-1 |
| CPO-RL4 | MB3170 | EGX100MG |
| IO-351-A 96161720-V01 | CES-A-UEA-04B 097075 | M100-RTD |
| EB401 EB401-10 | ED-SxED 22176716 | SB522A |
| MC350-4T-2S | Q.PS-AD2-2402F | C-9402 |
| PS00B02KNX | SensION1 5170060 | SB-DIM4c3A-DN |
| RS20-0800T1T1SDAPHH05.0.02 | TMT112-AAAAA | E080-04 |
| X87-813 | TCSESM043F23F0 | cPCI-R3610T |
| CCHE-CP24-D3-P003CH | PCO3000AM0 | IG6614 |
| SK41-32 | RXV-35-4K/4K | edmk-itf-c2 |
| TST8804 | FX03 / LP-FX03A11-0C | CLTG38EXPN01 |
| AC2257 | EPX420D | msv930 |
| CLIOP821A | ID22W00TCH300 | M19D902781G3 |