Hel Raadinta Bilaawga

Ugaasuhu wuxuu soo laabaa soon.
Imayl
Name
Mobile
Magaca shaqada
Xogta
0/1000

Siemens

Safarada>Maltid>Siemens

Siemens 6ES7513-1FL01-0AB0 SIMATIC CPU 1513F-1 PN

Magacga Cusub: SIMATIC S7-1500F CPU 1513F-1 PN
Magac Cilmi: Siemens
Lambarka Mudelka: 6ES7513-1FL01-0AB0
Goobta La Iibay: Jarmal
Garanti: 12 Bilood
WhatsApp: +86 180 2077 6782
Imeeli: [email protected]

Appurtenance:
  • Tusmarta
  • Amniga Qaaddanka
  • Soo noqonka PROFINET
  • Xoggaarka
  • Xiriiri
  • Su’aalaha loo isticmaalo badan
  • Other Products
  • Alaabta la sugaynayo
Kontrolleerka S7-1500 ee la xiriira amniga ah leh intarfeyska PROFINET IRT ee laba guriga oo dhan
CPU 1513F-1 PN wuxuu leeyahay 450 KB memoryga codka, 1.5 MB memoryga wararka, iyo kontrolka PROFIsafe ee amniga ah oo la xiriira mashinada ee leh ujeedada dhexe. Waa qof ka baxday oo la siiyey, sidaa darteed waxaad u baahan tahay inaad isku daydo taliyaha hardware, firmware, leebalka projectka TIA Portal, F-signature, iyo SIMATIC Memory Card ee loo baahan yahay.
Takhsis ka soo badelka F-system: Ku dhaqan karaa projectka standard iyo amniga ah ee la xiriira, F-signature, firmware, qoraalka Memory Card, magaca PROFINET iyo adreesaska IP, topoolojiyada device, sertifikeetkooda, iyo bufferka diyaagnosiska ilaa marka aanu CPU-ga asalka ah ku jirno.

Amniga Qaaddanka

6ES7513-1FL01-0AB0 waa CPU 1513F-1 PN ee SIMATIC S7-1500F ee la xiriira automationka standard iyo amniga ah. Intarfeyska PROFINET IRT ee dhexeeya wuxuu leeyahay switchka laba guriga iyo taageerada controller, device, iyo communicationka real-time ee shabakadaha la xiriira.
Badalka waa shaqo la xiriira safka amaanta, aan la aado badalka qofka ku jira. F-programmka la isticmaalo, ilooyinka gacmeedka, magaca alaabta, PROFIsafe-ka adreseedka ku dhowaanshaha iyo sababta amaanta ka dib ugu dambeeyey waa inay la sameeyo iyo la heeshaan.
Badalka F-CPU oo la xiriira waxa uu bilaabmaa marka projeektiga la xaqiijiyey iyo dhammaan sababta amaanta la heeshaan.
Project archive
Ku dhaqan karaa projeektiga TIA Portal ee la badali karo, f-signature, leegga software, passwords iyo haaladda alaabta online ka hor inta aanu guurto.
Kaartka Xaadka
Aqoonsi iyo ku dhaqan karaa SIMATIC Memory Card; CPU wuxuu u baahan yahay card-ka si ay u helayo memory-ka iyo si ay u bilaabo.
Tajriba ee ku saabsan isku dayn
Marka la soo galeyey, hubi kasta oo alaabta PROFIsafe, emergency stop, guard circuit iyo sababta amaanta la codsay ee la isticmaalo iyadoo la eegayo test plan-ka la isticmaalo.

Soo noqonka PROFINET

Magaca alaabta, isku dhafan-kii IP iyo topology waa sababaha ugu badan ee CPU-ka la badaliyey oo la xiriira ay ku nool yihiin STOP.
Aqoonsiga network-ka
Qor magaca PROFINET ee CPU, isku dhafan-kii IP, ports iyo topology ee la eegayaa ka hor inta aanu controller-ka ah ugu horreeyey.
I/O ku dhowaansan
Ku saabsan in kasta oo qorsho ee IO iyo qorsho ee F ay la heli karin kuwa xisaabta, isku dhafan kasta oo qorsho iyo tusaaleyaasha PROFIsafe.
Buufuurka Diyaagnosiska
Xidhiidhka STOP, isku dhafan kasta oo qorsho, dhaqaaqda xidhiidhka iyo warbixintii aaminimaha ka hor inta aan la badaliyo qorsho ama firmware.

Xoggaarka

Magaca ahaanta mawduuca
CPU 1513F-1 PN
Taksiimada Fadlan
6ES7513-1FL01-0AB0
Xaaladda Shirkada Qalabka
FS03
Version Firmware
V2.9 ee ku jira warbixin caadiga ah
Khaasimada Shaqo ee Barnaamijka
450 KB
Khaasimada Shaqo ee Daata
1.5 MB
Ku xidhiynta Memmori
Waxaa loo baahan yahay SIMATIC Memory Card; ugu yar 32 GB
Xiriirka PROFINET
IRT leh 2-port switch la gudbiyey
Wax time ee bitka
40 ns taasoo ku jira habka caadiga ah
Voltage-ka sahayda
24 V DC; 19.2 ilaa 28.8 V DC
Waxqabadaha ahaanta
CPU ee aaminimaha leh oo leh tusaaleyaasha PROFIsafe
Codka Haysta
Qorsho ee la joojiyey; qorsho cusub 6ES7513-1FM03-0AB0

Xiriiri

Qaansado
Kuuriga lacagta iyo kuwa la heli karaa
Lacag bixinta
T/T ama xaaladaha la qoray
Waqooyinka Ku Cararan
La saabsanayaa kuwa la soo qoray
Daryeelka
DHL, FedEx, UPS ama xaaladaha la qoray
Warantii
boqortooyada 12 Bulsho

Su’aalaha loo isticmaalo badan

Q1
Sida xaqiiqayaasha ugu fahmi karaan in 6ES7513-1FL01-0AB0 waa CPU ee aaminimaha leh ee sax ah oo la sameeyey S7-1500 rack?
Ku dhaqan isticmaal numberka guud ee amar, xaaladda shakhsiyaadka hardware, firmware iyo Memory Card, kadib aad ku tixgelisaa xaaladda hardware ee TIA Portal, topology PROFINET iyo f-program signature. Numberada qofka CPU 1513 ama numberada ka dambeysa ayaa la isku dayn karaa.
Q2
Waa maxay ugu muhiimsan ee lagu dhisay ilaa in 6ES7513-1FL01-0AB0 loo badalo waa isticmaalka nolosha?
Ku dhaqan projectka TIA Portal oo waxba laga heli karo, f-signature oo la xaqiijiyey, macluumaadka firmware ee CPU, qoraalka Memory Card, xalinta gacanta, magacaalaha device ee PROFINET iyo addresska IP, parametirada PROFIsafe, bufferka diagnostik iyo rekordka ugu dambeysa ee la xaqiijiyey ee nolosha.
Q3
Maxaad 6ES7513-1FL01-0AB0 ku jiraan STOP ilaa in SIMATIC Memory Card ee asalka ah loo sameeyo?
Isticmaal bufferka diagnostik iyo ku tixgelisaa kuwa xaaladda hardware iyo firmware, qoraalka card, xalinta dhaqanka iyo moduleyada la xaqiijiyey. Wax yaabta ah ee projectka, dhammaan firmware ee la xaqiijin karo, device ka qayb ahaan, ama wax yaabta ah ee safety-program wuxuu ku jiraa RUN.
Q4
Sida ku saabsanaya xiriirka PROFINET ka dib marka la badalo 6ES7513-1FL01-0AB0?
Soo dhawoow magaca qofka PROFINET iyo soo dhawoow isku dhafaynta IP, dhaqaaqda xiriirka joojinta ah ee ka hor, kadib awooda kala duwan ee IO iyo F-qofka online. Xariijin magaca la isku mid ah, qofka aan la helin, iyo kala duwanaanshaha moduulka ka hor inta aan la sameeyo xiriirka mashinka.
Q5
Ma aha in 6ES7513-1FL01-0AB0 loo badalo si toos ah naqshada ka dambe ee uu leeyahay bilaabidooda project?
Ha ka qaybqaadidin in la badalo si toos ah. Naqshada ka dambe wuxuu leeyahay kala duwanaansho kala duwan ee ujeedada iyo data ee heerka dhammaadka, sidaa darteed waxaad ugu yaraan isku dhafaynta hardware-ka ee project-ka la xariijinayo, awooda firmware iyo taliyaha TIA Portal, soo dhawoow programa ee amaanta iyo soo noqon kala duwanaanshooyinka la baahan yahay.
Q6
Waa maxay taajabiyada amaanta oo lagu baahan yahay ka hor inta 6ES7513-1FL01-0AB0 loo soo noqdo shirkadda ka dib marka la gudbiyey?
Ku xidhiidh F-signature-ka iyo xasiloonka dhaqan, jirro dhammaan koodhaha xaaladaha caafimaadka iyo qalabka xaaladaha caafimaadka, ku xidhiidh tijaabooyinka PROFIsafe iyo waqtiga xaaladaha caafimaadka, oo daaqo tijaabada kuwa la isticmaalay in la xaqiijiyo. Tijaabada caafimaadka ah ee ugu yar ee la isticmaalayo ma ahan mid ka badan.

Other Products

POL95U.00
002640
KS40 - 9404 406 40991
110063001 2RP
PM5300 METSEPM5320
POL635.00
3113A
107-MX
140 CPU 113 02
1SAP450000R0001 AO523
CU351O 100-240V9
PXM20
440R-G23216 MSR142RTP
EY200
ENCL-MZ800-PAN
295619-003
PDT 3100 / STBPDT3100
IQE35-1201U80035
6590 COMP-Y/C
MMX-400 / MMX-1 300
LV540003 CVS400F
CMD5B9102
LNL-1320
Wrt-822B
S-532-0 s UNC532
P8-HDMI2-4KDS
GX-7
LBB4442/00
BSAP-2035 17000949F1
M8CS 2C13793G06

Hel Raadinta Bilaawga

Ugaasuhu wuxuu soo laabaa soon.
Imayl
Name
Mobile
Magaca shaqada
Xogta
0/1000

Hel Raadinta Bilaawga

Ugaasuhu wuxuu soo laabaa soon.
Imayl
Name
Mobile
Magaca shaqada
Xogta
0/1000