ProSoft 5201-MNET-MCM Modbus TCP/IP to Modbus Gateway

INDUSTRIAL MODBUS GATEWAY5201-MNET-MCM
Product Name:Modbus TCP/IP to Modbus Master/Slave Gateway Direct product enquiryWhatsapp:+86 18020776782Email:[email protected]
Brand Name:ProSoft Technology Model Number:5201-MNET-MCM
Place of Origin:USA Warranty:12 Months
Appurtenance:
  • Overview
  • Specifications
  • Commercial Terms
  • Description
  • Protocol Gateway Architecture
  • Gateway Integration Advantages
  • FAQ
  • After-Sales Support
  • Other Products
  • Recommended Products

Contact info

Sales Email Phone/Whatsapp
Jim Pei [email protected] +86 18020776782

Specifications

Parameter
Verified value
Model 5201-MNET-MCM
Product Family ProLinx 5000 Series
Gateway Function Modbus TCP/IP to Modbus Master/Slave
Mounting DIN rail
Ethernet Port 1 RJ45 port
Serial Application Ports 1
Modbus TCP/IP Roles Client and Server
Server Connections Up to 5 independent clients
Server Ports 502 and 2000
Client Connections 1 client connection
Client Device Capacity Up to 100 servers/devices
Client Command Capacity Up to 100 commands
Serial Modes Master or Slave; RTU or ASCII
Serial Baud Rate 110 to 115,200 baud
Stop Bits 1 or 2
Data Size 7 or 8 bits
Parity None, even or odd
RTS Timing Delay 0 to 65,535 ms
RTU Error Check CRC-16
ASCII Error Check LRC
Modbus Slave Address 1 to 247
Serial Interfaces RS-232, RS-422 or RS-485
Serial Port Isolation 2,500 V RMS signal isolation
Port-to-Ground Isolation 3,000 VDC minimum
Power Supply 24 VDC nominal; 18–36 VDC allowed
Current Load 500 mA maximum at 24 VDC
Operating Temperature -20 to +50°C
Storage Temperature -40 to +85°C
Relative Humidity 5–95%, non-condensing
Standard Dimensions 13.2 x 5.25 x 11.48 cm (H x W x D)

Commercial Terms

Minimum Order Quantity 1 Piece
Price Contact for Jim
Packaging Details Original new Factory Sealed
Delivery Time 3–7 Days
Payment Terms T/T
Shipping Method DHL / FedEx / UPS / TNT
Supply Ability Brand new, In Stock

Description

5201-MNET-MCM is a ProSoft ProLinx gateway that links Modbus TCP/IP networks with Modbus Master/Slave serial devices. It provides one Ethernet port and one individually configurable serial application port. The Ethernet driver supports both Client and Server operation, while the serial driver supports Master or Slave operation in RTU or ASCII mode. Up to 100 client commands can address as many as 100 TCP/IP servers or devices. The stand-alone aluminum gateway mounts on DIN rail and operates from an 18–36 VDC supply.

5201-MNET-MCM allows existing serial meters, drives, controllers and instruments to exchange data with Ethernet-based control systems. Its shared internal database moves information between the two protocol sides without requiring a PLC rack module. Configurable command timing, timeouts, retries and address offsets support deterministic integration.

Industrial serial isolation and status indicators simplify commissioning and troubleshooting. The exact 5201 designation identifies the one-port serial version and should not be confused with the four-port 5202-MNET-MCM4.

Protocol Gateway Architecture

01 · RECEIVEModbus TCP/IP message

The Ethernet driver receives Client or Server transactions through the RJ45 port.

02 · MAPShared internal database

Address mapping places network data into the gateway database.

03 · CONVERTSerial Modbus command

The serial driver issues Master or Slave transactions in RTU or ASCII mode.

04 · RETURNResponse exchange

The gateway returns device data to the requesting Ethernet application.

Gateway Integration Advantages

01Protocol bridgeSerial Modbus devices can participate in a Modbus TCP/IP system. 02Dual Ethernet rolesClient and Server support covers both polling and served-data applications. 03Flexible serial configurationRS-232, RS-422 and RS-485 support Master or Slave operation.
04Large command listUp to 100 configurable client commands address as many as 100 devices. 05Industrial isolationSerial signal and ground isolation protect communication paths. 06Standalone mountingDIN-rail construction avoids consuming a PLC rack slot.

FAQ

01. How many serial application ports are provided by 5201-MNET-MCM?The 5201 version provides one serial application port; the 5202-MNET-MCM4 provides up to four.
02. Can 5201-MNET-MCM act as both a Modbus TCP/IP Client and Server?Yes, the MNET driver supports both Client and Server connections.
03. Which serial formats can 5201-MNET-MCM use?Its serial port supports Modbus Master or Slave operation in RTU or ASCII mode.
04. What database role does 5201-MNET-MCM perform?A shared internal database transfers mapped data between the Ethernet and serial drivers.
05. What should be backed up before replacing 5201-MNET-MCM?Save the PCB configuration, IP settings, command list, serial parameters and address mappings.
06. When will 5201-MNET-MCM be released for delivery?Processing begins after payment and typical delivery is 3–7 days.

After-Sales Support

01 Warranty Support Most products are covered by a warranty of up to 12 months, subject to the applicable terms and conditions. If any product-related issue occurs during the warranty period, our team will assist you and provide an appropriate solution.
02 Technical Documentation Relevant datasheets and technical literature can be provided with the goods, offering useful information for product identification, installation, operation, and maintenance.
03 Fast Response We understand the importance of minimizing equipment downtime. Our team responds promptly to inquiries and provides professional assistance with product information, quotations, order status, shipping, and after-sales questions.
04 Global Customer Service We serve customers worldwide and provide reliable assistance from inquiry to delivery and after-sales service, ensuring clear and timely communication throughout the process.
05 Long-term Spare Parts Supply We continue to source discontinued, obsolete, and hard-to-find automation parts from various brands, helping customers maintain existing equipment and reduce downtime caused by spare parts shortages.

Other Products

LD5 TM118 099-1003-07 E100
MK15-12EX0-PN/24VDC/K11 MN80C 807224 IQ8
DT72 002612 DL50F/S176 16276
9470-26-904-102 6MBI300U4-120-01 RH328A
X-301-I 6ES7421-7BH01-0AB0 MC-1000-8M05A10-SC
KHA6-SR2-EX2.W 33804S 251402-AP TSW-552-BS 6506895
KFA6-SR2-Ex2.W 103373S FG-20i 1631005-003 MTL5032
HAI100 4K / 60-1364-01 9251-2-10 F124x04 Fnr 07400030
RH390 9470-004-A1 TXM1.8X
FMM-4-20 L01-0259-001 FC2XN-24-10AS ABB 6126/01-83-500
VE3A1102 K9701PM / PLC24 PNOZ S4 C 751104
R134A / 067N5019 1756-0B16E KNX-GW-DMX KNX/TP
OC-485 GMP201-C 110072003

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000