allen bradley controllogix 1756 1756 dhrio dh plus remote io communication module-0

Allen Bradley ContrlLogix

Home >  Products >  ROCKWELL >  Allen Bradley ContrlLogix

Allen-Bradley ControlLogix 1756 1756-DHRIO DH Plus Remote I/O Communication Module | Original New

Allen-Bradley ControlLogix 1756 DH Plus Remote I/O Communication Module
Complete Model
1756-DHRIO
Official Product Description
Allen-Bradley 1756-DHRIO ControlLogix dual-channel Data Highway Plus and Remote I/O communication module with individually selectable DH+ or RIO channels.
CORE FEATURE: Two individually selectable DH+ or Remote I/O channels in one ControlLogix chassis slot.
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Features
  • Interfaces
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
1756-DHRIO is an Allen-Bradley ControlLogix 1756 communication module for Data Highway Plus and Universal Remote I/O networks.
Its two channels are individually selectable for DH+ or Remote I/O operation. As an RIO scanner it supports 32 logical rack connections or 16 block-transfer connections per channel.
The module occupies one ControlLogix chassis slot and supports communication rates of 57.6 Kbps, 115.2 Kbps and, on channel A, 230.4 Kbps.

Technical Data

Complete model
1756-DHRIO
Brand
Allen-Bradley / Rockwell Automation
Product family
ControlLogix 1756
Product type
Data Highway Plus and Remote I/O communication module
Lifecycle status
Discontinued as of December 31, 2024
Communication networks
Data Highway Plus and Universal Remote I/O
Number of channels
2, individually selectable for DH+ or Remote I/O
Communication rates
57.6 Kbps and 115.2 Kbps on both channels; 230.4 Kbps on channel A
Remote I/O operation
Scanner only
Remote I/O capacity
32 logical rack connections or 16 block-transfer connections per channel
Connections supported
32 maximum
Backplane current draw
850 mA at 5.1 VDC; 1.7 mA at 24 VDC
Power dissipation
4.5 W
Thermal dissipation
15.4 BTU/hr
Isolation voltage
30 V continuous, basic insulation; type tested at 877 VDC for 60 seconds
Network cable
Belden 9463 copper twinaxial, 0.519 square mm / 20 AWG
Dimensions
Numeric dimensions are not stated in official publication 1756-TD003R; one-slot ControlLogix chassis module
Weight
Not stated in official publication 1756-TD003R for this exact catalog number
Slot width
One ControlLogix chassis slot
Module location
Chassis-based, any slot
Compatible chassis
1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17
Enclosure type
None, open-style equipment
Operating temperature
0 to 60 degrees C
Storage temperature
-40 to +85 degrees C
Relative humidity
5 to 95 percent, noncondensing
Vibration
2 g at 10 to 500 Hz
Shock
30 g operating; 50 g nonoperating
Certifications
cULus, CSA, CE, RCM, ATEX, IECEx, UKEX, UKCA and CCC when marked
Official sources
Rockwell Automation 1756-DHRIO product page; publication 1756-TD003R-EN-E pages 18 to 24; publication 1756-IN070B-EN-P pages 5 to 8

Inquiry

Features

Dual network channels
Channels A and B can be configured independently for Data Highway Plus or Remote I/O service.
Remote I/O scanner
Each channel supports as many as 32 logical rack connections or 16 block-transfer connections.
Controller messaging
The module routes DH+ messages among supported ControlLogix, PLC and SLC controllers.
Multiple rates
The module supports 57.6 and 115.2 Kbps on both channels, with 230.4 Kbps available on channel A.

Interfaces

Channel A
Configure as DH+ or Remote I/O; supports 57.6, 115.2 and 230.4 Kbps.
Channel B
Configure as DH+ or Remote I/O; supports 57.6 and 115.2 Kbps.
Network media
Use Belden 9463 copper twinaxial cable and the specified three-pin connector and torque.
Backplane interface
Install the module in one slot of a compatible 1756 chassis and include 850 mA at 5.1 VDC in the power budget.

Installation

01 - Verify the exact catalog number
Match 1756-DHRIO on the quotation, module label, packaging and Rockwell Automation product record.
02 - Plan channel roles
Define whether channel A and channel B will operate as DH+ or Remote I/O before wiring and configuration.
03 - Confirm chassis power
Reserve one compatible 1756 chassis slot and verify the backplane power budget for the published current draw.
04 - Connect the network
Use the specified Belden 9463 twinaxial cable, observe polarity and connector torque, and maintain the required cable routing.
05 - Commission routing and I/O
Configure link IDs, rates and RIO racks, then verify module indicators, message paths and every intended I/O connection.

Environment

Operating temperature
0 to 60 degrees C.
Storage temperature
-40 to +85 degrees C.
Relative humidity
5 to 95 percent, noncondensing.
Mechanical endurance
2 g vibration at 10 to 500 Hz, 30 g operating shock and 50 g nonoperating shock.
Protection
Open-style equipment; install it in a suitable industrial enclosure.
Lifecycle
Rockwell Automation lists this catalog number as discontinued; compatibility and service strategy should be reviewed before procurement.

FAQ

Q1. How can the exact quoted 1756-DHRIO be verified?
Match 1756-DHRIO on the quotation, module label and packaging. Confirm two DH+/RIO channel connectors, the local programming port, one-slot ControlLogix format and the correct series marking.
Q2. How can New, Used or Refurbished condition be distinguished?
Request date-marked photos of the full label, serial and series markings, both channel connectors, local programming port, indicators, backplane connector and housing. Look for terminal wear, altered labels, repaired plastic and chassis insertion marks.
Q3. How should supplier legality and reliability be checked?
Verify the supplier legal entity, registered address, invoice details, payment beneficiary and traceable contact. The offer must state Allen-Bradley, 1756-DHRIO, condition, series, quantity and included connectors.
Q4. Which specifications must engineering confirm before purchase?
Confirm channel A and B roles, required DH+/RIO rates, rack and block-transfer counts, link routing, firmware and series compatibility, one-slot chassis fit, backplane power and Belden 9463 media.
Q5. What physical evidence should be requested before payment?
Ask for one date-marked photo set showing the complete 1756-DHRIO label, serial and series markings, both channel connectors, local programming port, front indicators, backplane connector, seals and packaging.
Q6. Can 1756-DHRIOXT, 1756-RIO or another module replace 1756-DHRIO?
Not automatically. 1756-DHRIOXT is the extended-temperature variant, while 1756-RIO has different scanner and adapter capabilities and does not provide DH+ operation. Confirm network roles, chassis, temperature, firmware and approvals before substitution.

Recommend Models

6310 2ZJEM
SCT-1250-100
1707-S1-T26B
330750-60
SW2L-64-HSB-DP
B&R X20-SYSTEM
HX85i 900-100295-01
RYB-922-6
100-A09ND3
WMZT1D08T
ARG30-N02G1-Z
LSP6B
QS-G1/8-6-I
NP8314C13E
MS2-H100
92125A128 35-725001-004
GE P112-6053
FAZ-C30/3
PZ-51LR
XL2000B3A
G205-16
2206-8033
7700-51101-S4X0500
C370BN
DS3800HVDB1K1G / 6BA06 C-ESS
F-650748P4
SACC-DSI-MS-12CON-PG9/0,5
A13-EB03M
VF350BM / PN: 4102947-511
DND20A-M060
SL1-F
NP-VBGT110304R-F
GE CR2810A14DE
Is220Pdoah1Bc
VI-2W4-IV
8501-CG14
3500/22 288055-01
FX-USI-0002
CG907A3
26-307-70E
592-B0V16
00321458-01
UMS-1XP
TK12W-007
A250-8002-Z350
68210-HH
5910.777
200-530-025-014
ABB NBMNAAABNEC1BNN1XF
WMZT1DX0
RXE2N0F7H132A
ZCP21
CSU600AT
NORD FLEXBLOC 60493000
6809 H.1010.6504
CF3-G8-AB
1746-OB16
SCOUT100-EX
5715-5M U-04912
2001-333

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000