BENTLY NEVADA | 3300 XL
330130-075-01-00
7.5 m Armored Standard Extension Cable
|
|
Selection: 7.5 m length | armored standard FEP cable | ClickLoc connectors | no connector protector | agency approval not required
LEAD TIME: In stock | WARRANTY: 1 year
|
OFFICIAL PRODUCT SUMMARY
3300 XL Extension Cable
A 75 ohm triaxial extension cable for the 3300 XL 8 mm Proximity Transducer System. The armored construction adds stainless-steel mechanical protection while retaining the standard FEP cable jacket.
|
Exact configuration: Code 075 specifies 7.5 m; code 01 specifies armored cable without connector protector; code 00 specifies no agency approval requirement.
Official datasheet:Document 141194 Rev. AN (specifications pages 4-9; ordering pages 18-19; dimensions pages 38-39).
|
|
Technical Data
Official data for 330130-075-01-00
|
|
Complete model
|
330130-075-01-00
|
|
Product family
|
3300 XL 8 mm Proximity Transducer System
|
|
Product type
|
Armored standard extension cable
|
|
Dimensions
|
Cable length 7.5 m, tolerance +20 / -0 mm; connector maximum outside diameter 7.24 mm; armor maximum outside diameter 7.67 mm; armor ferrule maximum diameter 10.2 mm
|
|
Weight
|
103 g/m typical for armored extension cable
|
|
Cable construction
|
75 ohm triaxial cable with FEP insulation and jacket; AISI 302 or 304 stainless-steel armor
|
|
Connectors
|
Two ClickLoc coaxial connectors; finger-tight connection
|
|
Minimum bend radius
|
25.4 mm
|
|
Core conductor resistance
|
1.65 +/- 0.25 ohm nominal
|
|
Jacket resistance
|
0.49 +/- 0.10 ohm nominal
|
|
Capacitance
|
69.9 pF/m nominal
|
|
Operating and storage temperature
|
-52 to +177 deg C for standard extension cable
|
|
System length rule
|
Probe plus extension cable length must equal the selected Proximitor Sensor system length
|
|
Agency approval option
|
00: agency approval not required
|
|
CONTACT
STELLA
|
|
System role and features
|
|
Signal path
Extends the probe cable to the Proximitor Sensor while preserving the calibrated 3300 XL system electrical length.
|
Armored protection
Flexible stainless-steel armor protects the standard FEP cable in mechanically demanding routing areas.
|
|
ClickLoc connection
Two ClickLoc connectors support a secure finger-tight probe-to-cable and cable-to-sensor connection.
|
Defined impedance
The official 75 ohm triaxial construction is part of the calibrated transducer system.
|
|
Key selection note: For a 9.0 m system, this 7.5 m cable is paired with a 1.5 m probe. The combined electrical length must match the Proximitor Sensor.
|
|
|
Part number breakdown
330130-075-01-00
|
|
330130
|
3300 XL standard extension cable
|
|
075
|
7.5 m cable length
|
|
01
|
Armored cable without connector protector
|
|
00
|
Agency approval not required
|
|
Installation and compatibility
|
|
System matching
Use only with a compatible 3300 XL 8 mm probe and Proximitor Sensor of the same total system length.
|
Recommended pairing
A 1.5 m probe plus this 7.5 m extension cable forms the official 9.0 m system length.
|
|
Cable routing
Maintain at least the 25.4 mm minimum bend radius and protect the cable from crushing or sharp edges.
|
Connector sealing
Tighten ClickLoc connectors finger-tight. Protect connections against oil exposure as specified by the official installation guidance.
|
|
Key selection note: Do not substitute a similar length or cable option without verifying the full probe, extension cable and Proximitor Sensor combination.
|
|
|
Environmental data
Published cable limits and construction
|
|
Cable temperature
|
-52 to +177 deg C operating and storage
|
|
Armor material
|
AISI 302 or 304 stainless steel
|
|
Jacket material
|
FEP
|
|
Moisture protection
|
Connector protection and sealing depend on the installed system and environment
|
|
Agency approval
|
Option 00: agency approval not required
|
|
Installation environment
|
Observe cable bend radius, connector protection and system-length requirements
|
|
Six checks before purchase
|
|
1. How can the quoted complete model be verified?
Require photographs of the label and packaging showing 330130-075-01-00. Confirm that the code decodes to 7.5 m, armored cable without connector protector, and no agency approval option.
|
|
2. How can New, Used or Refurbished condition be distinguished?
Ask for current photographs of both ClickLoc connectors, the FEP jacket, stainless-steel armor and ferrules. A new cable should not show connector wear, crushed armor, tight bends or installation residue.
|
|
3. How can supplier legitimacy and reliability be checked?
Verify the supplier legal entity, business address, traceable quotation, bank beneficiary and documented inspection process. Require the exact model and condition on every commercial document.
|
|
4. What must engineers check before purchase?
Confirm the 7.5 m length, armored option, two ClickLoc interfaces, 25.4 mm minimum bend radius and compatibility with the intended probe and Proximitor Sensor. Probe plus cable must equal the selected system length.
|
|
5. What physical evidence should be requested before payment?
Request dated photographs of the complete cable, both connectors, armor and label, plus a length-verification image and continuity or resistance test record tied to 330130-075-01-00.
|
|
6. Can a similar length or suffix replace this model?
Not automatically. A different length changes calibrated system length, and option 00 has no approval requirement. Any substitute must match cable length, construction, connectors and the exact probe-plus-cable system configuration.
|
|
Random cross-brand reference list
|
|
ETI-1
|
C320KGS22
|
Ext12D
|
|
176F9172 500V/P408
|
AW-HHD100E
|
GE S7714D-EST2
|
|
IA5150A-T
|
WP-700-EB
|
T/PI/S/-40
|
|
6ES7650-1BD51-0XX0
|
XC-ST30/XC-ST30/1
|
PW9001
|
|
ABB 6131/20-24-500 2CKA006132A0342
|
PSU1AC24VDC20ADN4014
|
TBS50 15855
|
|
3-RS232 EST33X
|
LNL-MT15-485
|
GE 80-517-3N-XTI 80-632-3N-XT
|
|
SG200-50
|
S5SBMB31
|
EP1502 10383 0
|
|
AT-RON-448 4K/HDR
|
F/E000000000005ER1301111
|
T-ASH-G2-500
|
|
DRC410F
|
R4410WT
|
ILAN485
|
|
802M-AY5
|
ABB TU515 1SAP212200B0002
|
025-40900-007 TRE 40-55L
|
|
ABB 51012P1 8300-0-8183
|
LA305-S/SP1
|
ADM51C-1-S3
|
|
OAW-AP1101
|
EIR505-M
|
LMS111-10100
|
|
LT-800-072
|
130B7485
|
mt3025 POL965.00
|
|
7PA3030-1
|
EC-7850-A-1072
|
MS-4AOVC
|
|
BMXCPS3020H
|
MA1578A
|
A4-F8C
|
|
04079200 (04077612) AM001
|
050-11-10m
|
ALM-1
|
|
3BA23197BAED
|
HD251X
|
V61R513A-A2000
|
|
NI9977 196917B-01L
|
HCPS.9-2508W
|
AAR145 AAR145-S00
|
|
RF432
|
PM554-T A0 ABB 1TNE968900R0100
|
ADV151-P13
|
|
ULOS-CIR-1500-WH
|
H4D1F1X
|
2160-A
|