Product Name: Two-wire Transducer
Brand Name: Bently Nevada
Model Number: 9200-06-05-10-00
Place of Origin: United States
Warranty: 12 Months
Whatsapp:+86 18020776782
Email:[email protected]
overview
| Product Name | Two-wire Transducer |
| Brand Name | Bently Nevada |
| Model Number | 9200-06-05-10-00 |
| Place of Origin | USA |
| Warranty | 12 months |
| Payment Methods | T/T |
| Shipment | DHL/UPS/EMS/Fedex... |
|
Sales: |
Email: |
Whatsapp: |
|
Jim Pei |
| Product Name | BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer |
| Manufacturer | BENTLY NEVADA |
| Product Type | Two-wire Transducer |
| Part Number | 9200-06-05-10-00 |
| Dimensions | 10.2x4x4cm |
| Weight | 0.42kg |
| Place of shipment | Xiamen, China |
| Country of origin | USA |
| Condition | New & Original in Factory Packing |
| Frequency Range | 1 Hz to 140 Hz for versatile monitoring |
| Frequency | 0 ±100, 10 Hz (600 cpm) |
| Connector Option | Terminal block top mount |
| Mounting Base Option | Circular; M10X1 stud |
| Agency Approval | No approvals required |
| Dynamic Sensitivity | 100 mV/g for accurate readings |
| GasketMaterial | 9200: Neoprene |
| Sensitivity Temperature Coefficient | 0.2%/°C |
| Operatingand StorageTemperature | -29°C to +121°C(-20°F to +250°F) |
The BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer is a robust vibration sensing device designed for continuous monitoring of machinery condition. Utilizing a two-wire loop-powered design, it simplifies installation while delivering reliable vibration measurement for industrial applications.
This transducer is ideal for monitoring low-frequency vibration in rotating equipment, helping operators detect imbalance, misalignment, and other mechanical issues early.
The BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer offers a frequency range of 1 Hz to 140 Hz, making it suitable for low-frequency vibration monitoring. It features a dynamic sensitivity of 100 mV/g for accurate signal output and supports a frequency specification of 0 ±100, 10 Hz (600 cpm).
The unit is equipped with a top-mounted terminal block connector for easy wiring and a circular mounting base with an M10×1 stud for secure installation. It uses a neoprene gasket material for sealing and durability, and maintains a low sensitivity temperature coefficient of 0.2%/°C to ensure measurement stability across varying temperatures.
The BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer simplifies system integration with its two-wire loop-powered design, reducing wiring complexity and installation costs. It provides reliable and stable vibration measurement, particularly in low-frequency applications where precision is critical.
Its rugged construction ensures long service life in industrial environments, while its high sensitivity improves fault detection capabilities. The compact design allows easy installation on a wide range of machinery, supporting efficient condition monitoring and predictive maintenance programs.
The BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer is designed to operate in industrial environments with a temperature range from -29°C to +121°C (-20°F to +250°F). It maintains stable performance under varying thermal conditions due to its low temperature coefficient.
The neoprene gasket enhances environmental sealing, providing resistance to dust and moisture, making it suitable for typical industrial installations.
Q1: What kind of connector does the BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer use?
A: The BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer features a top-mounted terminal block connector for simple and reliable wiring.
Q2: How stable is the 9200-06-05-10-00 Two-wire Transducer under temperature changes?
A: The BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer has a low sensitivity temperature coefficient of 0.2%/°C, ensuring stable performance across varying temperatures.
Q3: What industries commonly use the BENTLY NEVADA 9200-06-05-10-00?
A: The 9200-06-05-10-00 Two-wire Transducer is widely used in oil & gas, power generation, petrochemical plants, and general industrial machinery monitoring.
Q4: What makes the BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer suitable for continuous monitoring?
A: The BENTLY NEVADA 9200-06-05-10-00 Two-wire Transducer offers reliable signal output, durable construction, and stable performance, making it ideal for long-term continuous vibration monitoring.
| HONEYWELL | Bently Nevada | WESTINGHOUSE |
| 8C-PAIH52 51307070-175 | 330103-00-05-20-02-CN | 1C31116G02 |
| 51199932-200 51199932-200-RP | 330103-05-15-05-02-00 | 5X00109G01 |
| 8C-IP0101 51454362-175 | 10026-02-12-05-02 | 5X00226G01 |
| 51402573-100 | 10030-05-30-05-02 | 5X00273G01 |
| SC-UCMX01 51307195-175 | 330103-12-25-10-01-00 | 5X00489G01 |
| FC-QPP-0001 V1.3 | 330103-12-25-10-02-00 | 5X00105G14 |
| MC-TDID52 51304441-275 | 330104-12-20-10-01-00 | 3A99190G01 |
| DC-TPOX01 51307770-176 | 330194-17-25-15-00 | 7379A21G02 |
| CC-TAIX61 51307077-175 | 330104-06-14-50-02-00 | 7379A21G01 |
| FC-PSUNI2424 SPS6061-LF | 330105-02-12-15-12-CN | 7379A31G04 |
| 51303940-200 | 330854-080-25-00 | 5X00594G01 |
| 05704-A-0135 | 330101-00-19-10-02-00 | 3A99132G02 |
| 51303976-400 | 330104-10-18-10-01-00 | 3A99132G01 |
| FS-CPCHAS-0003 | 330104-00-20-10-02-00 | 7380A36G01 |
| CC-PDOD51 51454408-175 | 3300/45 | 1C31142G01 |
| DC-TDIL01 51307780-176 | 330104-04-10-05-01-CN | 3A99266G01 |
| 8C-PCNT01 51454363-175 | 330104-10-20-05-02-00 | 1C31233G04 |
| CC-TDOR01 51308376-175 | 330905-00-07-10-02-00 | 1X00188H01 |
| DC-TUIO31 51307772-176 | 330104-15-23-50-02-00 | 5X00357G04 |
| CC-SCMB02 51199942-300 | 330910-10-22-10-01-CN | 1C31222G01 5A26458G05 |