allen bradley compactlogix 5370 l3 1769 l30er nse 1 mb no stored energy controller-0

ROCKWELL

Home >  Products >  ROCKWELL

Allen-Bradley CompactLogix 5370 L3 1769-L30ER-NSE 1 MB No-Stored-Energy Controller

Allen-Bradley CompactLogix 5370 L3 1 MB No-Stored-Energy Controller
Complete Model
1769-L30ER-NSE
Official Product Description
CompactLogix 5370 L3 controller with 1 MB user memory, no supercapacitor for the real-time clock, dual Ethernet ports with DLR capability, eight local I/O modules and 16 EtherNet/IP nodes.
CORE FEATURE: No-stored-energy controller variant with 1 MB memory and dual Ethernet connectivity.
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications & Features
  • Connections
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
1769-L30ER-NSE is an Allen-Bradley CompactLogix 5370 L3 controller with 1 MB user memory and no supercapacitor for the real-time clock.
Rockwell Automation specifies two embedded Ethernet ports with Device Level Ring capability, support for 16 EtherNet/IP nodes and a maximum of eight local 1769 Compact I/O modules.
The controller includes a USB service port and ships with a 1 GB 1784-SD1 Secure Digital card; a separately ordered 2 GB 1784-SD2 card is supported.

Technical Data

Complete model
1769-L30ER-NSE
Product type
CompactLogix 5370 L3 no-stored-energy programmable automation controller
Brand
Allen-Bradley / Rockwell Automation
Product family
CompactLogix 5370 L3
Controller tasks
32 tasks; up to 100 programs per task
Ethernet interfaces
2 embedded Ethernet ports with Device Level Ring capability
USB interface
USB service port for temporary local programming
Nonvolatile memory
1784-SD1 1 GB card ships with controller; 1784-SD2 2 GB card supported
Backplane current
500 mA at 5 V DC and 225 mA at 24 V DC
Power dissipation
4.5 W maximum
Isolation
30 V continuous basic insulation, USB and Ethernet circuits to system; no isolation between Ethernet ports
Dimensions
118 x 55 x 105 mm, height x width x depth
Weight
Approximately 0.31 kg
Mounting
DIN rail or panel mount; M4 or #8 panel mounting screws
Operating temperature
0 to +60 degrees C
Storage temperature
-40 to +85 degrees C
Relative humidity
5 to 95 percent, noncondensing
Vibration
5 g at 10 to 500 Hz
Shock
20 g operating on DIN rail or 30 g operating on panel; 30 g nonoperating on DIN rail or 40 g nonoperating on panel
Enclosure
Open-style industrial equipment
User memory
1 MB
Stored-energy feature
No supercapacitor for the real-time clock
Integrated motion
Not specified for this catalog number
EtherNet/IP nodes
16 maximum
Local I/O modules
8 maximum 1769 Compact I/O modules in one bank
Official source
Rockwell Automation publication 1769-TD005O-EN-P, pages 3 to 8

Inquiry

Applications & Features

No stored energy
The NSE suffix identifies the variant without a supercapacitor for the real-time clock.
Dual Ethernet
Two embedded Ethernet ports support EtherNet/IP communication and Device Level Ring topologies.
Local I/O expansion
The controller supports up to eight local 1769 Compact I/O modules in one bank.
Removable storage
A 1 GB 1784-SD1 Secure Digital card ships with the controller, with a 2 GB 1784-SD2 option supported.

Connections

Ethernet port 1
Embedded EtherNet/IP port for controller, I/O and device communication.
Ethernet port 2
Second embedded Ethernet port for linear or Device Level Ring network operation.
Ethernet cable
RJ45 connector with Category 5e minimum cable according to TIA 568-B.1, or Category 5 cable according to ISO/IEC 24702.
USB service port
Temporary local programming connection; the USB cable must not exceed 3.0 m and must not contain hubs.
Compact I/O bus
Right-side 1769 Compact I/O expansion interface for up to eight local modules.

Installation

01 - Verify the complete suffix
Match 1769-L30ER-NSE on the quotation, controller label, packaging and Rockwell Automation product record.
02 - Confirm NSE suitability
Verify that the application requires the no-supercapacitor real-time-clock variant and that timekeeping behavior is acceptable.
03 - Plan the I/O bank
Keep the local bank within eight 1769 Compact I/O modules and include the required power supply and end cap.
04 - Mount the controller
Install on a compatible DIN rail or panel while reserving the 118 x 55 x 105 mm controller envelope.
05 - Commission the project
Install the Secure Digital card, configure the dual Ethernet network and validate the firmware and Studio 5000 project.

Environment

Operating temperature
0 to +60 degrees C.
Storage temperature
-40 to +85 degrees C.
Humidity
5 to 95 percent relative humidity, noncondensing.
Vibration
5 g at 10 to 500 Hz according to IEC 60068-2-6.
Operating shock
20 g on DIN rail or 30 g on panel according to IEC 60068-2-27.
Nonoperating shock
30 g on DIN rail or 40 g on panel according to IEC 60068-2-27.

FAQ

Q1. How can the exact quoted 1769-L30ER-NSE be verified?
Match the full 1769-L30ER-NSE catalog number on the quotation, controller label and packaging. The NSE suffix is essential because it identifies the no-supercapacitor real-time-clock version.
Q2. How can New, Used or Refurbished condition be distinguished?
Request date-marked photos of the complete label, Ethernet ports, USB port, SD card slot, I/O bus connector, DIN-rail latch and packaging. Check for connector wear, scratches, repairs and altered labels.
Q3. How should supplier legality and reliability be checked?
Verify the supplier legal entity, registered address, payment beneficiary and traceable sales contact. The written offer must state the full 1769-L30ER-NSE suffix, condition and quantity.
Q4. Which specifications must engineering confirm before purchase?
Confirm 1 MB memory, no supercapacitor for the real-time clock, 16 EtherNet/IP nodes, eight local 1769 modules, dual Ethernet with DLR, 118 x 55 x 105 mm space and approximately 0.31 kg weight.
Q5. What physical evidence should be requested before payment?
Ask for one date-marked photo set showing the complete 1769-L30ER-NSE label, serial and series markings, both Ethernet ports, USB port, SD slot, I/O bus, mounting latch, seals and packaging.
Q6. Can 1769-L30ER replace 1769-L30ER-NSE?
Not automatically. 1769-L30ER uses the standard internal energy-storage solution, while 1769-L30ER-NSE omits the real-time-clock supercapacitor. Confirm the stored-energy requirement and exact suffix before substitution.

Recommend Models

SL1-B
PSU18915A
1771-ID
GLC-SX-MM-RGD-PRO 1000BASE-SX
91909455 K0406
E2E-X2D1-N
FX-USI-0002
C06.440-120
7ND4460-1DA46-1AA2
2F893
CEI33-3
IC693ALG221B
GCP-33A
EASYGEN-3400-5 /P2 8440-2078
OTS 60PB
NF50-SRU3015
080B11V
MS2-H100
2190-E31PA
C70TC3HKHF8NH6DM8VP67U67W67
MP093S .093
6SE7022-6EC61-Z
08056D106KAT2A
S020253 00A40C-002
7VK61
SMB100A
NGS-3U
WMZT2C02T
204D1382P002
AR420A
A03B-0815-C002
TAPCON260
NCDQ2A50-6DZ
500-5M-25
A03B-0815-C003
SNAP-PS24
NBN15-F11-E2
SL-126-A24Q/R
FR13E
KN88PA
SK12L-E01
A1SJ71UC24-R2 RS-232-C
ZM071H
OMICRON ,CMC 430
CH13S
P2S-EW362ES2CQ
NDN13
8US1261-5FM08
DN-Q12B-2-2-A
F351B1-301
8501X000 8501XTE1
4XHBU-SS
ABB LS45M91B11
CPX-AB-8-M8-3POL
F-2224HC,783510-16100
R9853350
06137 175MA
EL-40216-094C-1.2.4 PRG10094
800T-A6D2
SLVU2.8-8.TBT

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000