siemens 6es7412 3hj14 0ab0 simatic s7 400h cpu 412 3hsiemens 6es7412 3hj14 0ab0 simatic s7 400h cpu 412 3h fault tolerant controller-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6ES7412-3HJ14-0AB0 SIMATIC S7-400H CPU 412-3H

Product Name: SIMATIC S7-400H CPU 412-3H Fault-Tolerant Controller
Brand Name: Siemens
Model Number: 6ES7412-3HJ14-0AB0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • H-System Recovery
  • Description
  • DP Diagnostics
  • Specifications
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
Fault-tolerant S7-400H processor with MPI/PROFIBUS DP and dual synchronization interfaces
CPU 412-3H provides 768 KB work memory, one MPI/DP interface and two optical synchronization-module interfaces for S7-400H and S7-400F/FH systems. Replacement must preserve the H-system configuration, firmware alignment, synchronization hardware, project and memory strategy.
H-system and firmware check: Confirm both H-system CPU order numbers, firmware V4.5 compatibility, STEP 7 hardware configuration, rack and slot, MPI/DP network, IF 960 synchronization modules and optical paths, memory card and battery state before replacing either subsystem.

H-System Recovery

Both redundant subsystems, their synchronization path and their project state must be treated as one controlled system.
Subsystem record
Capture both CPU order numbers, firmware, rack and slot, operating state and diagnostic buffers.
Synchronization path
Identify both IF 960 modules, fiber routes and normal synchronization indications before disconnection.
Project baseline
Keep the complete STEP 7 H-system project, hardware configuration, blocks, symbols and safety records.

Description

6ES7412-3HJ14-0AB0 is the SIMATIC S7-400H CPU 412-3H for redundant S7-400H and safety-related S7-400F/FH systems. It provides 512 KB program memory, 256 KB data memory, one MPI/PROFIBUS DP interface and two slots for optical synchronization submodules.
A controlled replacement requires a verified STEP 7 archive and a record of both subsystem states. Capture CPU firmware, hardware configuration, diagnostic buffers, memory and battery condition, DP addresses, IF 960 module details and synchronization-fiber routing before shutdown.

DP Diagnostics

Separate CPU, fieldbus and synchronization faults before deciding that replacement hardware is defective.
MPI/DP network
Record address, baud rate, master configuration, termination, repeaters and all expected DP devices.
Diagnostic buffer
Save entries from both CPUs and relevant modules before clearing alarms or changing configuration.
Controlled test
Verify redundancy, communication, CiR behavior and controlled I/O response after the system is synchronized.

Specifications

Product type designation SIMATIC S7-400H CPU 412-3H
Order number 6ES7412-3HJ14-0AB0
System use S7-400H and S7-400F/FH
Firmware reference V4.5
Work memory 768 KB total: 512 KB program and 256 KB data
Primary interface MPI / PROFIBUS DP, up to 12 Mbit/s
Synchronization 2 interfaces for IF 960 optical synchronization modules
Engineering STEP 7 V5.3 SP2 or higher with hardware update
Power consumption Typical power loss 5.5 W
Installation width 2 slots
Dimensions 50 x 290 x 219 mm
Approximate weight 0.99 kg

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

Contact info

FAQ

Q1
How can I verify that 6ES7412-3HJ14-0AB0 is suitable for the existing S7-400H system?
Match both subsystem CPU order numbers, firmware V4.5 compatibility, two-slot space, STEP 7 hardware configuration, MPI/DP requirements and the IF 960 synchronization modules. For an F/FH system, include the approved safety project and lifecycle constraints.
Q2
What should be backed up before replacing 6ES7412-3HJ14-0AB0?
Archive the complete STEP 7 H-system project and compare it online with both CPUs. Save diagnostic buffers, hardware configuration, program and data blocks, DP network details, CPU firmware, memory-card data and the documented safety signature where applicable.
Q3
Why can 6ES7412-3HJ14-0AB0 fail to synchronize with the partner CPU?
Compare CPU and firmware compatibility, operating states, loaded hardware configuration and IF 960 module types. Inspect both synchronization fibers and connectors, review diagnostic buffers on both sides and resolve any memory or project mismatch before another restart.
Q4
How should one subsystem containing 6ES7412-3HJ14-0AB0 be replaced without losing redundancy control?
Follow the approved S7-400H maintenance sequence, identify the active and standby subsystem and confirm the process risk. Replace only the documented side, restore the verified configuration and do not release the system until synchronization and redundancy diagnostics are normal.
Q5
What should be checked when the MPI or PROFIBUS DP network does not recover with 6ES7412-3HJ14-0AB0?
Verify the CPU interface mode, address, baud rate, cable and termination, configured DP masters and expected devices. Compare the online hardware view with the project and read the CPU and interface diagnostics before changing the program.
Q6
How should CiR changes be handled after installing 6ES7412-3HJ14-0AB0?
Confirm that the approved project and affected modules support Configuration in RUN, review the expected synchronization time and process effect and make one controlled change at a time. Verify both H subsystems, diagnostics and I/O behavior before closing the change record.

Other Products

K1222/1 V01R02 VLC-853-KH
VDA-445SMB S653 176F2178
CD20 88 970 875 XDB-C18 DO820 3BSE008514R1
WR3387K-8 010-0901-000 LP-1200 RBS-4A-R
TZ350 02-SSC-4760 IE-3000-4TC f418
2CDG120005R0011 025-29583-001 100-260-XX
S4-700 PHDVM-63DM VX1020
3500/20 125768-01 S2403-0050 R8LED RDY2000
527471 19D903536P1 330904-00-06-05-02-05
046-00093-01 808-8214 60-1883-01 P3LB HENF209568R0001