siemens 6dl1134 6jh00 0eh1 simatic et 200sp ha ai 16xtc 8xrtd analog input module-0

SIMATIC S7 Series

Home >  Products >  SIEMENS >  SIMATIC S7 Series

Siemens 6DL1134-6JH00-0EH1 ET 200SP HA Analog Input Module

Product Name: SIMATIC ET 200SP HA AI 16xTC / 8xRTD Analog Input Module
Brand Name: Siemens
Model Number: 6DL1134-6JH00-0EH1
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Channel Planning
  • Description
  • Diagnostics
  • Specifications
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
High-availability temperature input module for 16 thermocouples or eight RTD channels with channel diagnostics
The ET 200SP HA module supports TC, RTD, resistance and low-voltage measurements with 16-bit conversion, channel-specific interference suppression and diagnostics. It can be used redundantly with terminal block M1 and supports reparameterization in RUN.
Drive-service checkConfirm H1 or M1 terminal-block wiring, TC or RTD sensor type, 2/3/4-wire configuration, reference-junction method, channel parameter set, cable resistance and redundancy architecture before replacement.

Channel Planning

Channel range, sensor wiring and reference-junction design must agree with the field installation.
Thermocouples
Confirm TC type, polarity, compensation cable and internal, external or group reference-junction method.
RTD wiring
Match the sensor type and 2-, 3- or 4-wire connection and account for lead resistance where required.
Redundancy
Use the correct M1 terminal block and approved redundant configuration when high availability is required.

Description

6DL1134-6JH00-0EH1 is a SIMATIC ET 200SP HA analog input module for up to 16 thermocouples or eight resistance thermometers. It is designed for high-availability process I/O and supports channel diagnostics, limit alarms and firmware updating.
Commissioning should start from the approved hardware configuration. Verify each channel range, sensor wiring, cold-junction or reference-channel setting, interference-frequency suppression and diagnostic reaction before reconnecting process trips or control loops.

Diagnostics

Channel-specific LEDs and diagnostic alarms help isolate sensor, wiring and parameter faults.
Wire break
Compare the affected channel wiring and parameterized sensor range before replacing the module.
Value quality
Review quality information, overflow/underflow and limit alarms together with the raw process value.
Noise rejection
Set 16.6, 50 or 60 Hz interference suppression to suit the installation and expected conversion time.

Specifications

Product type designation
AI 16xTC / 8xRTD 2/3/4-wire HA
Order number
6DL1134-6JH00-0EH1
Analog inputs
16 voltage/thermocouple channels or 8 RTD/resistance channels
Resolution
Up to 16 bit including sign
Terminal blocks
H1, M1, N0, H0 or M0; redundancy with M1
Supply
24 V DC, 19.2 to 28.8 V
Diagnostics
Wire break, overflow/underflow, supply and channel/module status
Configuration in RUN
Reparameterization supported
Operating temperature
-40 to +70 degrees C horizontal; -40 to +60 degrees C vertical
Dimensions
22.5 x 115 x 138 mm
Weight
Approximately 150 g

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

Contact info

FAQ

Q1
Which sensors can be connected to 6DL1134-6JH00-0EH1?
The module supports multiple thermocouple types, resistance thermometers and resistance or low-voltage ranges. Confirm the exact channel parameter, wiring method and terminal block against the approved ET 200SP HA configuration before connection.
Q2
How is redundancy implemented with 6DL1134-6JH00-0EH1?
Siemens specifies redundancy capability with terminal block M1. Verify the station design, paired-module configuration, channel assignments and process reaction before installing or replacing either redundant partner.
Q3
How should 6DL1134-6JH00-0EH1 be wired for RTD measurements?
Match the parameterized RTD type and select the correct 2-, 3- or 4-wire circuit. Check terminal-block coding, lead resistance, shield routing and channel assignment, then validate temperature values with a known reference.
Q4
Why can 6DL1134-6JH00-0EH1 report wire break or overflow after replacement?
Common causes are an incorrect sensor range, reversed or open wiring, wrong terminal assignment, missing reference-junction configuration or a parameter set that does not match the field device. Review channel diagnostics before changing hardware again.
Q5
Can 6DL1134-6JH00-0EH1 be reparameterized without stopping the station?
The module supports reparameterization in RUN, but the effect on the measured value, alarms and process logic must be assessed. Use an approved change procedure and monitor quality information while the parameter is applied.
Q6
How should noisy measurements from 6DL1134-6JH00-0EH1 be diagnosed?
Check shielding, grounding, cable routing, sensor continuity and common-mode conditions, then verify the selected 16.6, 50 or 60 Hz interference suppression and smoothing. Compare one channel at a time with a stable test source.

Other Products

ABB 3BSE008510R1 DO810 67CFR-239 250PSI/0-125PSI 60-1026-81
VP9805 54-64111 DS2416 MID1E-800
140471-01 ABB 63754 MCW-211-SM-LC15 pn.3645-0030
B818-263 15B10932G1 RP12-GSM
MT 701 V2.0 6825 90 ABB 1TNE968900R1110 PM564-T-ETH CL510
ABB MT70 1.2 SR GHQ6050059R0006 PGD0000W00 LBB1946/00
6308 D40/D90X23 ABB 12.1600 605 0056 R0002 ABB 1SAP250600R0001 AI531 1SAP212200R0101
VCL-E1-030 UGC8000 GC8000 CL-D-333-P1
KJ2003X1-BA2 12P2093X102 IMX-M 102F DDM-163 05-008-163 DKL-013
A51 6762250 DZL AE4 6762264 AE02 FC-TSDI-1624C MIL-RC3412 10/100BASE-TX