Siemens 6DL1135-6TF00-0EH1 ET 200SP HA HART Output Module

Product Name: SIMATIC ET 200SP HA AQ 8xI HART Analog Output Module
Brand Name: Siemens
Model Number: 6DL1135-6TF00-0EH1
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Description
  • HART Integration
  • Loop Diagnostics
  • Specifications
  • Contact info
  • Commercial Term
  • FAQ
  • Other Products
  • Recommended Products
Eight-channel high-availability current output module with HART communication and channel diagnostics
AQ 8xI HART HA provides eight short-circuit-proof current outputs with HART support, 16-bit resolution for 4 to 20 mA operation and channel-level diagnostics. It supports redundancy with terminal block M1 and parameter updates during operation.
Loop, HART and terminal-block check: Confirm the exact output range, H1 or M1 terminal block, two-wire actuator loops, load resistance, channel parameters, HART device assignments and redundancy partner before replacement or commissioning.

Description

6DL1135-6TF00-0EH1 is the SIMATIC ET 200SP HA AQ 8xI HART analog output module. It supplies eight current loops, supports 0 to 10 mA, 0 to 20 mA and 4 to 20 mA ranges and provides HART communication, substitute values and channel diagnostics.
Commissioning should follow the approved hardware and channel configuration. Verify each loop with the field device safely isolated, confirm load and polarity, then test HART access, diagnostic reactions, quality information and redundant failover where used.

HART Integration

Channel assignment, current-loop design and HART device identity should be verified as one system.
Loop range
Match 0 to 10, 0 to 20 or 4 to 20 mA configuration to the connected actuator and control logic.
HART identity
Record device tag, polling address, parameter set and expected secondary variables before exchange.
Redundancy
Use terminal block M1 and the approved paired-module configuration when high availability is required.

Loop Diagnostics

Use channel diagnostics and a controlled loop test to separate wiring, load and parameter faults.
Wire break
Check loop continuity, terminal assignment, load and the configured output range before replacing the module.
Short circuit
Isolate the field loop, verify polarity and resistance and inspect the actuator or cable for a grounded fault.
Value quality
Review channel status, substitute-value behavior and HART communication together with the commanded output.

Specifications

Product type designation
AQ 8xI HART HA
Order number
6DL1135-6TF00-0EH1
Analog outputs
8 short-circuit-proof current outputs
Output ranges
0 to 10 mA, 0 to 20 mA and 4 to 20 mA
Resolution
Up to 16 bit including sign
Actuator connection
Two-wire current output
Load resistance
150 to 750 ohms in rated range
Terminal blocks
H1, M1, N0, H0 or M0; redundancy with M1
Supply
24 V DC, permissible range 19.2 to 28.8 V
Diagnostics
Supply, wire break, short circuit and overflow/underflow
Operating temperature
-40 to +70 degrees C horizontal; -40 to +60 degrees C vertical
Dimensions / weight
22.5 x 115 x 138 mm; approximately 160 g

Contact info

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

FAQ

Q1
Which terminal block is required for redundant use of 6DL1135-6TF00-0EH1?
Siemens specifies redundancy capability with terminal block M1. Confirm the approved ET 200SP HA redundant pair, channel assignment, failover behavior and process reaction before installing either module.
Q2
How should a 4 to 20 mA actuator be connected to 6DL1135-6TF00-0EH1?
Use the documented two-wire output terminals, correct polarity and a load within the rated range. Parameterize the channel for 4 to 20 mA, then prove zero, span and the safe process response with the field loop controlled.
Q3
Why can 6DL1135-6TF00-0EH1 report wire break after replacement?
Check the selected range, terminal-block coding, channel wiring, actuator continuity and minimum loop load. Compare the restored parameter record with the original configuration before replacing the module again.
Q4
How can HART communication be verified on 6DL1135-6TF00-0EH1?
Confirm the channel is enabled for HART, identify the connected device and polling address and check loop current and load. Read the HART diagnostics and compare the device tag and parameters with the archived commissioning record.
Q5
Can 6DL1135-6TF00-0EH1 be reparameterized while the station remains in RUN?
The module supports parameter changes in RUN, but the resulting output, substitute-value and alarm behavior must be assessed. Apply one approved change at a time while monitoring channel quality and the controlled process.
Q6
What should be tested after installing 6DL1135-6TF00-0EH1?
Verify supply and module diagnostics, command each output through its approved range, confirm HART access and alarm reactions and test the substitute value. In redundant applications, perform the documented failover test before release.

Other Products

305228-PR 370710B-200 402712-PR
BA21747-040-00 SA6200A-201 750-841 3x750-432 3x 750-531 750-600
998-1105-016 9274CBTE-0010 DS10 LV CEAS410751-01-01 / HK50AA003
F9342LP-05 HMIDT551 MNL-13R MNL-13RF3
A5E00247018 SB401-13 42716625-V1
XSWM2APU2NQ15 GLB166.1P BA327C
1606-XLE240EN 450-00019-004 LSM4N
TC906D1006 279221-PR ABB RMBA-01
1756-CNBR/E PN:14151 50PLC-M03 QCS33
000435 51303932-476 2711-T10C20

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000