Siemens SIMATIC ET 200SP 6ES7135-6HB00-0DA1 AQ 2xU/I High Speed Analog Output Module | Original New

Siemens SIMATIC ET 200SP
6ES7135-6HB00-0DA1
AQ 2x U/I High Speed analog output module for BU type A0 or A1, with two voltage/current channels, channel diagnostics and 16-bit resolution.
KEY SPEC: 2 analog outputs; 125 us minimum cycle; voltage and current ranges; accuracy up to +/-0.2%.
LEAD TIME: In stock   WARRANTY: 1 year
  • Overview
  • Technical Data
  • Inquiry
  • Functions
  • Diagnostics
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Siemens SIMATIC ET 200SP 6ES7135-6HB00-0DA1
AQ 2xU/I High Speed Analog Output Module
6ES7135-6HB00-0DA1 provides two high-speed analog output channels for voltage or current signals in distributed SIMATIC ET 200SP stations. It supports rapid synchronized control, flexible output ranges, channel diagnostics and operation with BaseUnit type A0 or A1.
High-Speed Output
Two analog outputs operate with a minimum 125 us module cycle. Oversampling supports up to 16 values per cycle for fast, precisely timed control tasks.
Voltage and Current Ranges
Selectable ranges include 0 to 10 V, 1 to 5 V, -5 to +5 V, -10 to +10 V, 0 to 20 mA, -20 to +20 mA and 4 to 20 mA.
Resolution and Accuracy
Resolution reaches 16 bit including sign. The operational error limit is +/-0.2% across the overall temperature range; the basic limit at 25 C is +/-0.1%.
Channel Diagnostics
The module reports supply-voltage monitoring, wire break for current outputs, short circuit for voltage outputs, overflow, underflow and group errors.
System Integration
Use with ET 200SP BaseUnit type A0 or A1. Engineering is supported from TIA Portal V13 SP1, STEP 7 V5.5 SP3, PROFINET GSDML V2.3 and PROFIBUS GSD Revision 5.
Compact Construction
The module measures 15 x 73 x 58 mm and weighs approximately 31 g. It uses a type A mechanical coding element and module color code CC00.

Technical Data

Technical Data
Complete model
6ES7135-6HB00-0DA1
Brand
Siemens
Product family
SIMATIC ET 200SP analog output modules
Product type
AQ 2xU/I High Speed analog output module
Output channels
2 analog voltage/current outputs
BaseUnit compatibility
BU type A0 or A1
Color code
CC00
Supply voltage
24 V DC; permissible range 19.2 to 28.8 V DC
Current consumption
45 mA rated without load; 90 mA maximum with two 20 mA current outputs
Power loss
0.9 W typical
Minimum module cycle
125 us
Oversampling
Yes; up to 16 values per cycle
Voltage ranges
0 to 10 V; 1 to 5 V; -5 to +5 V; -10 to +10 V
Current ranges
0 to 20 mA; -20 to +20 mA; 4 to 20 mA
Maximum resolution
16 bit including sign
Operational error limit
+/-0.2% for voltage and current across the overall temperature range
Basic error limit at 25 C
+/-0.1% for voltage and current
Voltage load
Minimum 2 kohm; maximum capacitive load 1 uF
Current load
Maximum 500 ohm; maximum inductive load 1 mH
Shielded cable length
Up to 1,000 m; 200 m for voltage output
Diagnostics
Supply monitoring, wire break, short circuit, overflow/underflow and group error
Operating temperature
-30 to 60 C horizontal; -30 to 50 C vertical; below 0 C from functional status FS06
Installation altitude
Up to 5,000 m; restrictions above 2,000 m per manual
Dimensions
15 x 73 x 58 mm (W x H x D)
Weight
Approximately 31 g
Engineering
TIA Portal V13 SP1; STEP 7 V5.5 SP3; PROFINET GSDML V2.3; PROFIBUS GSD Revision 5
Country of origin
Germany

Functions

Functions
Two High-Speed Channels
Both outputs can generate voltage or current signals. A 125 us minimum cycle and isochronous operation support fast closed-loop positioning, dosing and test-system control.
Oversampling
The module can output up to 16 values per bus cycle. Minimum resolution is 45 us with two active channels or 35 us with one channel.
Flexible Signal Generation
Voltage ranges cover unipolar and bipolar signals, while current ranges cover 0 to 20 mA, 4 to 20 mA and -20 to +20 mA. Substitute values can be configured for fault behavior.
Run-Time Configuration
Parameters can be changed in RUN. The module provides I&M0 through I&M3 identification and maintenance data for asset management.

Diagnostics

Diagnostics
Channel Monitoring
Current-output wire break and voltage-output short circuit are diagnosed channel by channel. Overflow and underflow states are also detected.
Module and Supply Status
The green PWR LED monitors supply voltage. Green channel LEDs show status, red LEDs identify channel diagnostics, and the green/red DIAG LED reports module status.
Output Protection
Voltage outputs are short-circuit protected with a maximum short-circuit current of 45 mA. The maximum externally applied voltage at an output is 30 V.
Isolation
Channels are isolated from the backplane bus and electronics supply. Isolation is type-tested at 707 V DC.

Installation

Installation
BaseUnit Selection
Install 6ES7135-6HB00-0DA1 on a SIMATIC ET 200SP BaseUnit type A0 or A1. The type A mechanical coding element and CC00 color code help prevent selection errors.
Actuator Wiring
Voltage outputs support two-wire and four-wire connection. Current outputs use a two-wire connection. Use shielded signal cable and observe the specified load limits.
Cable and Load Limits
For voltage output use at least 2 kohm and up to 1 uF capacitive load. For current output use up to 500 ohm and 1 mH. Shielded cable may reach 1,000 m, or 200 m for voltage output.
Engineering Compatibility
Configure from TIA Portal V13 SP1 or STEP 7 V5.5 SP3. The module is supported through PROFINET GSDML V2.3 and PROFIBUS GSD Revision 5.

Environment

Environment
Operating Temperature
Horizontal mounting is specified from -30 to 60 C; vertical mounting from -30 to 50 C. Operation below 0 C applies from functional status FS06.
Installation Altitude
Operation is specified up to 5,000 m above sea level. Observe the manual restrictions for installation altitudes above 2,000 m.
Dry-Room Suitability
The specified minimum dew point is -60 C, supporting dry-room applications when the complete ET 200SP installation meets the required environmental conditions.
Compliance Data
The product is RoHS compliant from 31 March 2015. Siemens lists an environmental product declaration and classifies the item as country of origin Germany.

FAQ

FAQ
Q1. How can I verify that the quotation is for the exact model?
Require the full order number 6ES7135-6HB00-0DA1 on the quotation, nameplate and package label. It must identify the ET 200SP AQ 2xU/I High Speed module for BaseUnit type A0 or A1, not another AQ variant.
Q2. How can I distinguish a new unit from used or refurbished stock?
Ask for current photos of the sealed package, module front, side label, terminals and serial or production markings. Inspect for opened seals, terminal marks, scratches, replaced labels or signs that the type A coding element has been used.
Q3. How should I check whether a supplier is legitimate and reliable?
Verify the legal company registration, business address, bank beneficiary and a reachable company-domain contact. Ask for recent traceable transaction references and written confirmation that the quoted item is 6ES7135-6HB00-0DA1.
Q4. Which technical points should an engineer confirm before purchase?
Confirm two voltage/current outputs, BU type A0 or A1, 24 V DC supply, required voltage or current range, 125 us minimum cycle, load impedance, shielded cable length and engineering compatibility with the installed ET 200SP station.
Q5. What physical evidence should be requested before payment?
Request dated photos or video showing the exact label 6ES7135-6HB00-0DA1, intact packaging, accessory and terminal condition, quantity, and a readable serial or production code. Evidence should match the seller name and quotation.
Q6. Can a similar suffix or another ET 200SP AQ module replace this part?
Not automatically. Different suffixes can change channel count, speed, range, accuracy, BaseUnit requirement, diagnostics or engineering support. Substitute only after the project engineer confirms electrical, mechanical and configuration compatibility.

Recommend Models

Recommend Models
A randomized selection of industrial automation models for additional sourcing reference.
1756-L73
5069-L330ERMS2
6ES7153-2BA10-0XB0
6ES7231-5ND32-0XB0
AAI143
ASR133
6ES7234-4HE32-0XB0
PM861AK01
1756-DHRIO
PM5132-T-ETH
6ES7534-7QE00-0AB0
1756-L75
CC-TCF911
TU847
1756-L74
6ES7521-1BH10-0AA0
1756-A10
6ES7288-1CR40-0AA1
6ES7288-5BA01-0AA0
6ES7222-1BH32-0XB0
CI867K01
TU844
6ES7518-4JP00-0AB0
SM560-S-FD-4
DP865
TU532
SD831
DI811
6ES7223-1PL32-0XB0
DI840
6ES7332-5HF00-0AB0
6ES7521-1FH00-0AA0
6ES7288-1CR30-0AA0
KJ3001X1-BA1
6ES7288-5AE01-0AA0
5069-L340ERMS2
TB541-ETH
VE3051C2
6ES7288-1CR40-0AA0
AAI543
6GK7543-1AX00-0XE0
6ES7288-1CR20-0AA1
6ES7241-1CH32-0XB0
1756-L81ES
1756-L84ES
KJ1501X1-BC2
PM891K01
AAP849
DI821
VE4001S2T1B1
1756-EN4TR
6ES7392-1AJ00-0AA0
6ES7288-1CR60-0AA1
6ES7505-0RB00-0AB0
6ES7223-1BL32-0XB0
6ES7288-1CR60-0AA0
6ES7522-1BL01-0AB0
VE4005S2B4
AFV10S
6ED1052-1MD08-0BA2

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000