Complete model
|
6ES7193-6BP00-0BD0
|
|
Product family
|
SIMATIC ET 200SP
|
|
Product type
|
BaseUnit BU20-P12+A0+0B, type D0
|
|
Terminal technology
|
Push-in terminals
|
|
Module slots
|
1, type D0
|
|
Potential group
|
Continued from the left; no new potential group
|
|
Process terminals
|
12 per slot
|
|
AUX terminals
|
0
|
|
Add-on terminals
|
0
|
|
Terminal conductor range
|
0.14 to 2.5 mm2; AWG 26 to AWG 14
|
|
P1 and P2 bus rating
|
120 V DC or 277 V AC as stated in the manual
|
|
Process terminal rating
|
Up to 277 V AC; 480 V between L1, L2 and L3
|
|
Current carrying capacity
|
5 A up to 60 deg C; P1 and P2 bus maximum 10 A
|
|
Mains filter
|
Integrated between N and FE
|
|
Potential separation
|
Backplane bus and power bus are isolated from supply voltage
|
|
Isolation test
|
3,100 V DC
|
|
Operating temperature
|
-30 to 60 deg C horizontal; -30 to 50 deg C vertical
|
|
Installation altitude
|
Up to 2,000 m; greater altitudes on request
|
|
Dimensions
|
20 x 117 x 35 mm (W x H x D)
|
|
Weight
|
Approximately 47 g
|
|
Hardware status
|
FS10 and higher
|
|
Approvals
|
CE, UKCA, UL, KC, RCM, FM and selected maritime approvals
|
|
Station wiring role
The BaseUnit provides the terminal and power-bus foundation for one ET 200SP type D0 I/O module.
|
Potential continuity
The unit continues the existing potential group from the left.
|
|
Backplane separation
The backplane bus is electrically isolated from the supply voltage.
|
Automatic encoding
Automatic encoding is supported for the installed electronic module.
|
|
Process connections
Twelve push-in process terminals are available for the installed I/O module.
|
Conductor capacity
Each applicable terminal accepts 0.14 to 2.5 mm2 conductors, AWG 26 to AWG 14.
|
|
AUX arrangement
The BU20-P12+A0+0B variant has no AUX terminals and no add-on terminals.
|
Power buses
P1 and P2 can carry up to 10 A; the process terminal current rating is up to 5 A.
|
|
Electrical isolation
Supply voltage is isolated from both the backplane bus and power bus.
|
Isolation strength
The official type test value is 3,100 V DC.
|
|
Filter path
An integrated mains filter is installed between N and FE.
|
Current limits
Observe the stated 5 A terminal capacity and 10 A P1/P2 bus limits when designing protection.
|
|
Mechanical size
The BaseUnit measures 20 x 117 x 35 mm and weighs approximately 47 g.
|
Mounting role
Fit one compatible ET 200SP type D0 electronic module in the single slot.
|
|
Wiring method
Use push-in terminals and conductor cross-sections from 0.14 to 2.5 mm2.
|
Environment
Operate from -30 to 60 deg C horizontally or -30 to 50 deg C vertically, up to 2,000 m altitude.
|
|
Q1. How can I verify that the quoted item is exactly 6ES7193-6BP00-0BD0?
Match the complete order number on the BaseUnit, packaging, quotation and invoice. Confirm BU20-P12+A0+0B, type D0, dark-colored version, 20 mm width, 12 process terminals and no AUX terminals.
|
|
Q2. How can I distinguish a new BaseUnit from a used or refurbished unit?
Request current photos of the Siemens label, push-in terminals, power-bus contacts, coding area, rail latch, housing and sealed packaging. Check for inserted-wire marks, bent contacts, scratches or replaced labels.
|
|
Q3. How should a buyer verify that the supplier is legitimate and reliable?
Confirm the supplier legal registration, physical address, bank beneficiary and SIMATIC ET 200SP transaction references. All documents should identify Siemens 6ES7193-6BP00-0BD0 consistently.
|
|
Q4. Which specifications should an engineer verify before purchasing?
Verify type D0 compatibility, BU20-P12+A0+0B terminal arrangement, potential group continuation, 12 process terminals, no AUX terminals, current limits, 20 x 117 x 35 mm dimensions and 47 g weight.
|
|
Q5. What physical evidence should be requested before payment?
Request timestamped photos or video showing the full order-number label, all push-in terminals, P1/P2 contacts, coding area, mounting latch, housing condition and unopened packaging.
|
|
Q6. Can another ET 200SP BaseUnit suffix replace 6ES7193-6BP00-0BD0?
Not automatically. Another suffix can change width, BaseUnit type, potential-group behavior, AUX terminals, process-terminal count, voltage ratings and module compatibility. Wiring and module selection must be validated.
|
|
1609C43G-01
|
ABB S800 TU830V1 3BSE013234R1
|
271019-AH
|
|
GTU0203
|
OLS6 OPM6
|
SL-2000-N
|
|
PA2
|
NBRN - ESGB
|
1088440
|
|
PZ16 9012600000
|
VZ0008.BD4 VAV-SDZ-K2-L
|
ABB CI502
|
|
OPTO22 / SNAP-PS5
|
24EE24-316
|
54Y2537
|
|
9448.808
|
FX818327
|
2866679 QUINT-PS/1AC/48DC/5
|
|
077F1594 ETC1H1
|
167A.000367
|
SC-MD04250
|
|
AC-500
|
2CDG110169R0011
|
1SAZ211201R1035 TA25DU-5.0
|
|
SP3-GT35
|
OP10
|
PLC-3.3EACI8C
|
|
MN50-LCD
|
DIA-2Q -352
|
DLP-PU/E
|
|
DL-K 16-130/T-EN54
|
IC200MDL650K
|
396351-01-8
|
|
3HE00028CAAA01 DDM-40/85C
|
SLMO24N-S30810-Q2168-X400-1
|
MPW-6 RS-232 PN:096151
|
|
TCM10-FSF2-ODB FSF2-ODB
|
CLS100-PPS 7ML56100AA10 7ML5610-0AA10
|
ABB 3BSE020838R1 3BSE020850R1
|
|
S331A
|
EDA61K-HB-0
|
CSM-200-1218
|
|
ABB/BBC GJR2242000R1 LR370A-E
|
1SAJ530000R1210 / UMC100
|
591305
|
|
DLAF8000
|
RCM-810
|
IQ3XCITE/96/UK/100-240 IQ3-4000U7096
|
|
RF-EV1012PI-K4 433-80PLUS
|
3G2080-EU
|
HP101A-L5W1W
|
|
5WG1 532-1DB51
|
TG-540-1-2-10 TG-540
|
PM300 50797
|
|
84-330001-001
|
INT69 TM 41A 240 S10
|
SPR-S8EZ
|
|
9150/20-11-10
|
BM11D
|
6ES7350-1AH03-0AE0
|