Complete model
|
6ES7412-2XK07-0AB0
|
|
Product family
|
SIMATIC S7-400 CPU 412
|
|
Product type
|
CPU 412-2 central processing unit
|
|
HW functional status
|
01
|
|
Firmware version
|
V7.0
|
|
Work memory
|
1 MB integrated: 512 kB program and 512 kB data
|
|
Load memory
|
Up to 64 MB FEPROM or 64 MB RAM by memory card
|
|
Supply
|
Power supplied through the system backplane
|
|
Input current
|
5 V DC: 0.9 A typical, 1.1 A maximum; 24 V DC: 300 mA maximum
|
|
Power loss
|
4.5 W typical
|
|
Processing time
|
31.25 ns typical for bit, word, and fixed-point operations; 62.5 ns floating point
|
|
I/O address area
|
4 kB inputs and 4 kB outputs
|
|
Interfaces
|
1 x MPI/PROFIBUS DP and 1 x PROFIBUS DP; both isolated RS 485
|
|
Transmission rate
|
Up to 12 Mbit/s on each interface
|
|
DP capacity
|
Up to 32 DP devices on interface 1 and 64 DP devices on interface 2
|
|
Required slots
|
1
|
|
Diagnostic buffer
|
Up to 3,200 entries
|
|
Operating temperature
|
0 to 60 deg C
|
|
Dimensions
|
25 x 290 x 219 mm (W x H x D)
|
|
Weight
|
Approximately 700 g
|
|
Approvals
|
CE, CSA, UL, cULus, FM, RCM, KC, EAC; ATEX II 3G Ex nA IIC T4 Gc
|
|
Engineering
|
STEP 7 V5.4 or higher with HSP 261
|
|
Program execution
Typical bit, word, and fixed-point operation time is 31.25 ns; floating-point operation time is 62.5 ns.
|
Memory resources
Integrated work memory totals 1 MB and can be complemented by memory cards for load memory.
|
|
Address capacity
The CPU provides 4 kB input and 4 kB output address areas with configurable process images.
|
Configuration in RUN
CiR is supported with a 100 ms basic synchronization load plus 30 us per I/O byte.
|
|
MPI/DP interface
The first isolated RS 485 interface supports MPI and PROFIBUS DP master or device operation to 12 Mbit/s.
|
Second PROFIBUS DP
The second isolated RS 485 interface supports PROFIBUS DP master or device operation to 12 Mbit/s.
|
|
Communication resources
Up to 48 total connections are available for PG, OP, S7 communication, and routing functions.
|
Isochronous operation
Both DP masters support equidistance and isochronous operation with a shortest stated clock pulse of 1.5 ms.
|
|
Diagnostic buffer
The integrated diagnostic buffer stores up to 3,200 entries; the preset value is 120.
|
Test functions
Block status, single-step operation, up to 16 breakpoints, status/control tables, and forcing are supported.
|
|
Message functions
Symbol-related, program, and process diagnostic messages are supported with configurable alarm resources.
|
Program protection
User-program password protection and block encryption with S7 Block Privacy are supported.
|
|
Rack installation
The CPU occupies one slot in a SIMATIC S7-400 central rack and receives power from the system backplane.
|
Interface cabling
Use PROFIBUS-compatible RS 485 network components and validate the intended MPI or DP role for each port.
|
|
Environmental limit
Operate from 0 to 60 deg C within the specified SIMATIC S7-400 cabinet environment.
|
Engineering requirement
Configure with STEP 7 V5.4 or higher and HSP 261 for this hardware version.
|
|
Q1. How can I verify that the quoted item is exactly 6ES7412-2XK07-0AB0?
Match the complete order number on the CPU label, quotation, packaging, and invoice. Confirm CPU 412-2, firmware V7.0, 1 MB work memory, two PROFIBUS-capable interfaces, and the 25 mm module width.
|
|
Q2. How can I distinguish a new CPU 412-2 from a used or refurbished unit?
Request current photos of the Siemens label, front cover, memory-card slot, MPI/DP connectors, backplane connector, rack latch, and packaging. Inspect for rack marks, connector wear, replaced labels, or resealing.
|
|
Q3. How should a buyer verify that the supplier is legitimate and reliable?
Confirm the supplier legal name, registration, physical address, bank beneficiary, and S7-400 transaction references. All documents should consistently identify 6ES7412-2XK07-0AB0.
|
|
Q4. Which specifications should an engineer verify before purchasing?
Verify STEP 7 compatibility, 1 MB memory split, two RS 485 PROFIBUS interfaces, required DP device counts, 25 x 290 x 219 mm dimensions, and approximately 700 g weight.
|
|
Q5. What physical evidence should be requested before payment?
Request timestamped photos or video showing the full order-number label, serial information, front indicators, both D-sub interfaces, memory-card slot, backplane connector, housing condition, and sealed packaging.
|
|
Q6. Can another CPU 412 suffix replace 6ES7412-2XK07-0AB0?
Not automatically. A different suffix can change memory, firmware, interface count, connector layout, STEP 7 requirements, rack compatibility, or approvals. Engineering must validate the exact hardware configuration first.
|
|
IOEXP-G06D
|
NXG-7003
|
59604 S10MD
|
|
XBTGT5330
|
HD110C
|
176F9172 500V/P408
|
|
KP12LK
|
ET-RM300
|
ZU-35
|
|
6GK1905-6AA00
|
NC-540-1-1-5
|
CT-253
|
|
1794-TB3/A
|
MSE-C20 352802
|
CM 6010P
|
|
IMD-IM20 IM20DEMO
|
LTMR100MFM
|
13090001
|
|
6ES7532-5NB00-0AB0
|
431425-PR
|
1C31234G01
|
|
003-004808-01
|
IQ3XCITE/96/UK/100-240 IQ3-4000U7096
|
CA5-10 1SBN010010R1010
|
|
GCU-HOSP-1
|
60-541-61
|
VC180
|
|
2201-85155-002
|
MNN-50-100 MN620
|
NTB-HD-10-S
|
|
PSU100S 6EP1332-2BA20
|
MHFP014BSSB
|
1957/00 (890019570001)
|
|
ABB Bio0007 2RCA026772A0001D / 2RCA026773D
|
704040/0-51-23 AC110
|
Ext12D
|
|
GE 3000
|
W7751F2011
|
MTL5021
|
|
AM900
|
EB0518(A) FXYMP-M
|
9977 cDAQ / cRIO
|
|
2250-R5D6S1
|
VE3A11701
|
SEC-TEA-230-5045
|
|
ABB LS40P13B11
|
700-F400A41
|
163 18 NH100
|
|
VP9186-4
|
ABB PM583/1SAP140300R0271
|
ABB 1SAJ655000R0100 VI155-FBP.0 UMC100
|
|
FPG-C32T FPO-E16T
|
3602B2BB2KKCA
|
Reg-K/4x/10
|
|
KFD2-GS-1.2W PN:38311
|
BZMD1-A125
|
XN-480 60-639-95R
|
|
753R-WE
|
VJP-4E
|
1100-0-4
|