Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens ti 405 analog input card 405 8adc ready for ship-0

SIEMENS

Home >  Products >  SIEMENS

SIEMENS TI 405 Analog Input Card 405-8ADC Ready For Ship

Product Name:Analog Input Card

Brand Name: SIEMENS

Model Number:405-8ADC

Country of Origin:GERMANY

Warranty: 12 Months

Whatsapp:+86 18159889985

Email:[email protected]

  • Overview
  • Contact for quotation
  • Specifications
  • Description
  • Applications
  • Features
  • Functions
  • FAQ
  • Recommended Products

Overview

Brand Name:

SIEMENS

Model Number:

405-8ADC

Country of Origin:

GERMANY

Packaging Details:

Original new Factory Sealed

Delivery Time:

Delivery time in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Parameter

Specification

Manufacturer

Siemens

Model Number

405-8ADC / 405-8ADC-1

Product Type

Analog Input Module for SIMATIC TI405

Number of Channels

8 high-precision analog channels

Analog Input Range

-10V to +10V or 0V to 10V, configurable per channel

Signal Type Compatibility

Voltage or Current (e.g., 4-20mA)

Sampling Rate

Up to 10 kHz (0.1 ms) per channel

Accuracy

±0.05% of reading (±2 LSB)

Resolution

12-bit

Communication Interface

RS485 (Modbus RTU), Profibus DP, or Profinet

Operating Voltage

24 VDC nominal (range: 10-30 VDC / 12-24 VDC)

Current Consumption

Max. 60 mA

Power Consumption

1W / 100 mW max

Operating Temperature

-25°C to +70°C (-13°F to +158°F)

Storage Temperature

-40°C to +85°C (-40°F to +185°F)

Environmental Humidity

0% to 95% RH, non-condensing

Isolation Voltage

500V DC (channel-to-backplane)

Dimensions

3.6x10.5x15cm

Material

Aluminum alloy with protective coating

Protection Rating

IP20-rated modular connector

Mounting

DIN rail / 24-pin DIN rail mounting connector

Description

The Siemens 405-8ADC is a robust analog input card for the SIMATIC TI405 PLC series, engineered to convert real-world analog signals into precise digital data. This 405-8ADC module features 8 high-precision input channels, efficiently handling multiple sensors for accurate monitoring. Its wide input range and configurable signal types ensure broad compatibility, making the 405-8ADC an essential solution for enhancing legacy automation systems with reliable, high-performance data acquisition for real-time process control and monitoring. 405-8ADC-1 is a related variant.

Applications

Legacy SIMATIC TI405 System Upgrades and Maintenance

Precise Process Control (Temperature, Pressure, Flow)

Industrial Data Acquisition and Signal Conditioning

Real-time Monitoring in Manufacturing Environments

Equipment Retrofit and Obsolescence Management

Features

Versatile Input Handling: Each of the 8 channels can be configured for voltage or current inputs.

High-Speed Data Acquisition: Provides high accuracy with a fast sampling rate up to 10 kHz for real-time control.

Robust and Durable Design: Features a rugged aluminum alloy construction with a protective coating and an IP20 rating for harsh industrial environments.

Seamless Integration: Supports RS485 (Modbus RTU), Profibus DP, or Profinet communication protocols for flexible system integration.

Temperature Resilience: Reliable operation within a wide temperature range from -25°C to +70°C.

Functions

Signal Conversion: Converts analog voltage/current signals from field sensors into 12-bit digital data for the PLC.

Real-Time Monitoring: Samples up to 8 differential input channels at high speeds for accurate process control.

Field Unit Interface: Connects a wide range of industrial transmitters and measuring devices to the TI405 PLC backplane.

FAQ

Q1: Is the Siemens 405-8ADC compatible with the newer SIMATIC S7 PLC systems?
A1: The 405-8ADC is specifically designed for the legacy SIMATIC TI405 PLC system. Direct compatibility with S7 systems depends on the specific backplane and communication architecture.

Q2: Can I mix voltage and current signals on different channels of the 405-8ADC?
A2: Yes, the 405-8ADC features a universal input design, allowing each of the 8 channels to be independently configured for either voltage or current ranges.

Q3: What is the actual sampling rate of the 405-8ADC card?
A3: The 405-8ADC card supports a maximum total throughput of up to 10 kHz, which distributes to approximately 1.25 kHz per channel when all 8 channels are active.

Q4: What happens if the 24V DC power supply to the 405-8ADC module fails?
A4: The 405-8ADC module will cease data acquisition. Most industrial control systems will then register a "Channel Fault" or "Module Failure" status, triggering a safe shutdown or an alarm sequence.

Q5: How do I verify the firmware revision of my 405-8ADC card?
A5: Firmware revision is typically not user-accessible via the module's front panel. It is usually read through the PLC configuration software when the 405-8ADC is scanned and initialized by the controller.

Inguiry Now: [email protected]