POWER
24 V AC/DC
|
OUTPUTS
4 relay outputs
|
|
LEAD TIME
In stock
|
WARRANTY
1 year
|
24 V compact controller
LOGO! 24RCE combines eight digital inputs and four relay outputs for low-voltage automation circuits.
|
Integrated network functions
Ethernet, web server, data logging and user-defined web pages are built into the display-equipped base module.
|
Modular automation base
A 400-block program capacity and expansion interface support compact machines, panels and building-control functions.
|
|
Complete model
|
6ED1052-1HB08-0BA2
|
|
Product family
|
LOGO! basic modules with display
|
|
Product type
|
LOGO! 24RCE logic module
|
|
Dimensions
|
71.5 × 90 × 60 mm (W × H × D)
|
|
Weight
|
Approx. 0.268 kg net
|
|
Mounting
|
35 mm DIN rail, 4 spacing units wide
|
|
Display
|
Integrated display
|
|
Rated supply voltage
|
24 V AC / 24 V DC
|
|
DC permissible range
|
20.4 to 28.8 V DC
|
|
AC frequency
|
47 to 63 Hz
|
|
Digital inputs
|
8
|
|
Digital outputs
|
4 relay outputs
|
|
Output protection
|
External fusing required
|
|
Program capacity
|
400 function blocks
|
|
Communication
|
Integrated Ethernet
|
|
Web functions
|
Integrated web server and user-defined web pages
|
|
Storage
|
Standard microSD card support
|
|
Operating temperature
|
-20 to 55 °C, no condensation
|
|
Storage / transport temperature
|
-40 to 70 °C
|
|
Certifications
|
CE, CSA, UL and FM; developed according to IEC 61131
|
|
Compact machinery
The 24 V input supply and relay outputs suit small machine sequences, interlocks and auxiliary control.
|
|
Panel automation
Eight digital inputs and four isolated relay outputs provide a compact control core for cabinet-based systems.
|
|
Building services
Timers, schedules and relay switching support lighting, ventilation and pump-control applications.
|
|
Networked operation
Ethernet and web functions allow parameter viewing and status monitoring from connected devices.
|
|
Logic and timing
The controller combines standard logic gates, multiple timers, counters and control functions within 400 program blocks.
|
|
Clock functions
An integrated real-time clock supports weekly and annual switching programs for scheduled control.
|
|
Data logging
Operating values can be recorded internally or on a standard microSD card for later review.
|
|
Diagnostics
Integrated display and extended diagnostic functions support commissioning and fault identification at the cabinet.
|
|
Ethernet communication
Connects to LOGO!, LOGO! TDE, SIMATIC controllers, SIMATIC panels and PCs.
|
|
Integrated web server
Provides display-based or user-defined web pages for network access to the control application.
|
|
Expansion connection
LOGO! expansion modules can increase digital and analog I/O within the permitted LOGO! 8 configuration limits.
|
|
Cloud and MQTT
LOGO! 8.4 provides cloud connection and MQTT support for connected control systems.
|
|
Mechanical mounting
Install on a 35 mm DIN rail and reserve four spacing units across the 71.5 mm module width.
|
|
Supply verification
Use a 24 V AC or 24 V DC source and verify DC voltage remains between 20.4 and 28.8 V.
|
|
Relay wiring
Size external fuses and conductors for the connected relay loads because external fusing is required.
|
|
Environment
Operate between -20 and 55 °C without condensation and maintain enclosure conditions within the stated limits.
|
|
Q1. How can the exact quoted model be verified?
The label and quotation must show 6ED1052-1HB08-0BA2 and LOGO! 24RCE with display, 24 V AC/DC supply, 8 DI and 4 relay outputs.
|
|
Q2. How can New, Used or Refurbished condition be distinguished?
Inspect the display, relay terminal screws, Ethernet port and DIN latch for tool marks or wear, and check that labels and packaging are intact.
|
|
Q3. How should the supplier be checked before purchase?
Confirm the supplier legal entity, payment account and traceable contact details, then require a written offer for the exact 24RCE order number and 24 V version.
|
|
Q4. Which engineering details should be checked before ordering?
Verify 24 V AC/DC supply compatibility, the 20.4–28.8 V DC range, eight digital inputs, four relay outputs, external fusing and the 71.5 × 90 × 60 mm envelope.
|
|
Q5. What physical evidence should be requested before payment?
Ask for dated close-ups of the full Siemens nameplate, display, 24 V supply terminals, relay outputs, Ethernet connector, DIN latch and packaging.
|
|
Q6. Can another LOGO! 24 V model replace this one?
Only after review. Some 24 V LOGO! models use transistor outputs or include analog-capable inputs, so output technology and wiring may not be interchangeable.
|
|
VS-ZP3102
|
SP-420
|
ABB 3BSE008518R1
|
|
M2000
|
6AG1222-1BF22-2XB0
|
ABB 1TNE968900R1110 PM564-T-ETH
|
|
EXP-10120
|
EZC100N
|
DIU211 2071670A
|
|
061046-A
|
DSx 264
|
MS652219PM
|
|
CP-168U 8-PORT RS-232
|
ABB PNU32.0/1SAJ263000R0100
|
ABB 500MDD01 1KGT034200R001
|
|
909569-02L P25 TERA2 512R RJ45
|
SMB9915-100-001-000-1D-1 SMB9915-1D-1
|
XT1B 160 530-0544
|
|
RV033873300 64R 250
|
DVI1500S
|
TSDW2CO
|
|
2CDG110153R0011
|
VROM-101
|
PRO6LV PRO6/PRO10
|
|
DDLE802
|
c-c500 500/MTP850,810Ex
|
HS2032NKCE
|
|
CB-400
|
LV430/LV830
|
7746FSE-HD
|
|
T-525W
|
MK15-12EX0-PN/24VDC/K11
|
GTD737
|
|
f170
|
IMC-101G
|
05 D0-05DR-D
|
|
EC30 50100-00
|
6ES7972-0CB35-0XA0
|
S2HC 472406
|
|
WLC316R
|
ABB PNU32.0 / 1SAJ263000R0100
|
QUINT-PS/1AC
|
|
QPA2000
|
VB552
|
Z012.041A/01 PRINT-F/P-AM01.1-F.SHW-SHTZAN-SI250
|
|
ABB CTRLON4S240
|
TSX-TPE01 / TSXTPE01
|
3HE00868CBAA01
|
|
1-EXT-PW
|
TECH2
|
RS20-0800T1T1SDAPHH05.0.02
|
|
DMC-4K-HD-DSP
|
2cdg110125R0011
|
5001270 PC0780-1
|
|
MBC5100 061B000266
|
BCM-815M 87815-10000-S012
|
GVAG-2VK1S
|
|
Fsc fs-iob-0001r
|
SX-300 / A700-1153
|
6FL4301-3CA11 6FL43013CA11
|