Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
6es7193 6bp20 0da0-0

SIMATIC S7 Series

Home >  Products >  SIEMENS >  SIMATIC S7 Series

Siemens SIMATIC ET 200SP 6ES7193-6BP20-0DA0 BaseUnit BU15-P16+A10+2D | Original New

SIEMENS SIMATIC ET 200SP
6ES7193-6BP20-0DA0
BaseUnit BU15-P16+A10+2D, type A0, light-colored, with AUX terminals
TERMINAL SYSTEM
Push-in connection
POTENTIAL GROUP
New load group
DIMENSIONS
15 x 141 x 35 mm
WEIGHT
Approx. 50 g
LEAD TIME
In stock
WARRANTY
1 year

Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications
  • Capacity & Technology
  • Compatibility
  • Lifecycle
  • FAQ
  • Recommend Models
  • Recommended Products

Technical Data

TECHNICAL DATA
Complete model
6ES7193-6BP20-0DA0
Product family
SIMATIC ET 200SP BaseUnits
Product type
BU15-P16+A10+2D, BaseUnit type A0
Rated supply voltage
24 V DC, maximum 10 A per supply terminal
Potential group
New potential group; feed from the left is interrupted
Process terminals
16 push-in terminals
AUX terminals
10 push-in AUX terminals
Additional terminals
2 terminals
P1/P2 current capacity
10 A maximum
AUX bus current capacity
10 A maximum
Process terminal current
2 A maximum
Conductor cross-section
0.14 to 2.5 mm² / AWG 26 to 14
Isolation test voltage
707 V DC
Operating temperature
-30 to 60 °C horizontal; -30 to 50 °C vertical
Installation altitude
Up to 5,000 m; restrictions apply above 2,000 m
Dimensions (W x H x D)
15 x 141 x 35 mm
Weight
Approx. 50 g

Applications

APPLICATIONS
01 · DISTRIBUTED IO
ET 200SP field wiring
The BaseUnit provides the mechanical and electrical interface between an ET 200SP I/O module and field conductors. Its 15 mm width supports compact decentralized control cabinets.
02 · POTENTIAL DISTRIBUTION
New load-group feed
The light-colored type A0 BaseUnit starts a new potential group by interrupting the P1, P2 and AUX buses from the left and feeding them through its supply terminals.
03 · AUXILIARY WIRING
Integrated AUX distribution
Ten AUX terminals distribute an additional potential across the local station, reducing separate terminal-block requirements while maintaining a structured wiring plan.

Capacity & Technology

CAPACITY & TECHNOLOGY
01 · TERMINAL ARCHITECTURE
16 process terminals plus 10 AUX terminals
Push-in connections support direct wiring of the process signals and auxiliary potential. Two additional terminals and the backplane interface complete the BU15-P16+A10+2D arrangement.
02 · ELECTRICAL CAPACITY
10 A buses and 2 A process terminals
The P1/P2 supply paths and AUX bus are each rated up to 10 A. Each process terminal is rated up to 2 A, subject to the approved conductor size and installation conditions.
03 · MODULE INTERFACE
BaseUnit type A0
The coding and terminal layout are intended for compatible ET 200SP I/O modules identified for BaseUnit types A0 or A1. The permitted module combination must be checked in the device manual.
04 · CABINET INTEGRATION
Compact 15 mm module width
The 15 x 141 x 35 mm BaseUnit preserves a narrow station footprint. The dimension drawing also shows the installed assembly depth and terminal positions for cabinet planning.

Compatibility

COMPATIBILITY
01 · I/O MODULE SELECTION
Check A0/A1 BaseUnit compatibility
Use only ET 200SP I/O modules whose documentation allows a BaseUnit type A0 or A1. Confirm the terminal use and required potential-group behavior before wiring.
02 · ARTICLE-NUMBER CONTROL
Preserve the complete order number
The single-unit article number is 6ES7193-6BP20-0DA0. The pack-of-ten article number shown in the manual is different and must not be substituted on purchasing documents.
03 · WIRING DESIGN
Coordinate P1, P2 and AUX potentials
The new potential group separates the left-hand bus feed. Verify conductor size, 24 V DC supply, load current, color-coding labels and the station potential plan before commissioning.

Lifecycle

LIFECYCLE
01 · PRODUCT STATUS
Active BaseUnit family
Siemens documentation lists the BU15-P16+A10+2D in the current ET 200SP BaseUnits manual and identifies the exact single-unit article number.
02 · IDENTIFICATION
Nameplate and package check
Match 6ES7193-6BP20-0DA0 on the package, product label and quotation. Record the short designation BU15-P16+A10+2D and the supplied quantity.
03 · INSTALLATION
Controlled station assembly
Mount the BaseUnit on the ET 200SP rail, establish the intended new potential group and complete field wiring with the specified push-in conductor range.
04 · MAINTENANCE
Traceable replacement
Before replacement, document the neighboring modules, terminal assignments, P1/P2/AUX potentials and color-coding labels so the station can be restored without wiring errors.

FAQ

FAQ
Q1. How can the quoted BaseUnit be verified as the exact model?
Check that the package and product label show 6ES7193-6BP20-0DA0 and the short designation BU15-P16+A10+2D. The official manual identifies this as the single-unit article; do not confuse it with the separate pack-of-ten number.
Q2. How can New, Used and Refurbished condition be distinguished?
Request dated photos of the sealed package, article label, terminal body, push-in openings, rail latch and bus contacts. A new BaseUnit should not show inserted-wire marks, terminal damage, rail scratches, contamination or replaced labels.
Q3. How should a buyer assess whether the supplier is legitimate and reliable?
Verify the legal entity, bank-account ownership, traceable quotation and after-sales terms. Ask for current photos that show 6ES7193-6BP20-0DA0, the package quantity and the physical BaseUnit, then compare them with the invoice and packing list.
Q4. Which specifications should an engineer confirm before purchase?
Confirm type A0, light-colored housing, new potential-group function, 16 process terminals, 10 AUX terminals, push-in conductor range, 10 A P1/P2 and AUX ratings, 2 A process-terminal rating, and the 15 x 141 x 35 mm envelope.
Q5. What physical evidence should be requested before payment?
Request timestamped images of the complete label, packaging seals, front terminal markings, P1/P2/AUX area, backplane contacts and rail latch. The quotation and packing list should use the exact 6ES7193-6BP20-0DA0 article number.
Q6. Can a similar BaseUnit suffix be used as a substitute?
Not automatically. A different suffix can change color, potential-group behavior, terminal count or AUX arrangement. Use 6ES7193-6BP20-0DA0 unless the responsible engineer confirms the official wiring and BaseUnit compatibility.

Recommend Models

RECOMMEND MODEL
ABB CL-LMT1SVR440721R1300
SDV531-S33/PRP
084B7250
ZB12-6 XTOB006BC1
60004-00X
tya604d
2200-84709-001
10300/1/1
RB2 BA4
499NOS17100
711-026017 R07 EX-UM-2X4SFP EX4200
DA1-101-EB-50 2661H10065
PCB00259-00
MTL-FS32
IPD1248C-T
HMT335
MES1B
66074
MNL-13RF3
8323 / ID-NO.417727L
DLM150
TP-0416AS
ABB 61085301F
915 J/K PT100 12V ICP22JI350000
ABB TA5142-RS485 1SAP187300B0003
ABB GJR2237600R1 DT370A 9093/019
171CCC78010 172PNN21022 170AAI14000
EN8400
NFDV151-P11
FWH-300A
PR 4114
PSR-SCP 24DC/ESP4/2X1/1X2 PSR-ESP4
X100 X100A
S261-22I RLA261T
Z031.408
RIA141X-EA
PH202
Allen-Bradley 1715-A3IO
UCL-16DI.DI r
500-688984
D000NH1DLF0
Sir88n Sir88n.a001
MC-1110-8M05A20
R4-2014-23-5230-WT
PC03000AM0
T-100
6027.134.000
2CDG 110 157 R0011
RLU220
1-24DC/600AC-30
UC12EPG-R
SNAP-24LC-MM
4032L
6590 COMP-Y/C
ABL8RPS24100
NT12DMC
MAC/MTA-E300 02710A
60-1883-01
ADAM-5069
DIN-PWS60

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000