| Model | 07EA61R1 |
|---|---|
| Product Family | Procontic T200 |
| Product Type | 8-channel analog input module |
| ABB Order Number | GJV3074351R1 |
| System | Procontic T200 |
| Input Channels | 8 |
| Input Signal | 4 to 20 mA |
| Resolution | 8 bit |
| Electrical Isolation | Common reference potential isolated from system |
| Nominal Insulation Voltage | 60 VAC |
| Test Voltage | 500 VAC |
| Open-Circuit Threshold | Approximately 3.6 mA |
| Input Resistance | 100 ohm |
| Current Resolution | 64.8 µA |
| Delivery Accuracy | ±1% |
| Resolution Error | ±0.5 LSB |
| Non-Linearity | ±0.5 LSB |
| Temperature Coefficient | ±2.78 µA/K |
| Maximum Input Current | +40 mA / -5 mA |
| Conversion Time | 5 ms |
| 5 V Supply Current | 60 mA maximum |
| 24 V Supply Current | 70 mA maximum |
| Power Dissipation | 1.98 W maximum |
| Shielded Cable Length | 50 m standard; up to 200 m with 2-core shielded cable ≥0.5 mm² |
| Terminal Conductor | 1.5 mm² maximum |
| Occupied I/O Points | 128 |
| Identifier | EW8 |
| Weight | 0.47 kg |
| Minimum Order Quantity | 1 Piece |
|---|---|
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
Identified as a ABB 8-channel analog input module, 07EA61R1 belongs to the Procontic T200 platform. It converts eight 4–20 mA process loops into an eight-bit input image for Procontic T200. The model-specific arrangement uses one isolated common reference potential for the complete channel group. Its installed interface detects an open current loop when the input falls below the documented threshold. These characteristics define the exact hardware boundary that must be matched when the component is sourced for an existing system.
For lifecycle support, 07EA61R1 supports transmitter current loops while maintaining the documented open-wire supervision path. The component is especially relevant where process value acquisition must remain predictable after service. Before removal, technicians should record the host location, connector orientation and project settings that govern legacy rack maintenance. Requires shielded cable routing and the original channel-to-address mapping during replacement. A controlled functional test should then confirm the restored path before the equipment returns to normal operation.
| SR2B201FU | UCL-16DI.DI r | PCOX000AA0 |
| PR502 | APS-PBC-60 | EDS-510A-1GT2SFP |
| 2CDG110030R0011 | SB-DN-PS1.2AD | 6ES7138-4FA02-0AB0 |
| A46128 | EZE-AC750T | AC1216 |
| C-Bus2 5034-NIRT | UC8 | LEM-320 |
| RK223 069-AS | 009SMA2 | MTL4531 |
| PPS640-KNX | EL4034 | E1210-T |
| ACU-485CNV-U | RXV-35-4K | AW-HHD100E |
| ABB 8300-0-8042 M251021P4 | PTSRB0101V3 | RTU32 UCN-26IOA/221B0130.D |
| 7900-0211-500rp WD5-BIAS | 253-pvmw | KFD2-UT2-1 116916 |
| EDS-508A | MVP100 | G2PF400VS02 |
| QAM2171.040 | W7754T4431 | EST 3-12/S1RY |
| CDH4U5 | SR3B261BD SR3 XT141BD | SR3B261BD |