Case / Cable
3.4 in / 2.0 m
|
Thread / Connector
3/8-24 UNF / ClickLoc
|
|
LEAD TIME
In stock
|
WARRANTY
1 year
|
CERAMIC TIP
Alumina ceramic cap with helium leak-tested ceramic-to-metal interface.
|
PRESSURE RATING
Official pressure seal rating of 34 bar (500 psi) nitrogen.
|
SYSTEM COMPATIBILITY
Compatible with the 3300 Proximitor Sensor and extension cable.
|
|
Complete model
Complete model
|
146054-34-20-02-05
|
|
Product family
Product family
|
Bently Nevada 3300 Ceramic Capped Probe
|
|
Product type
Product type
|
3/8-24 UNF forward-mount ceramic-capped proximity probe without armor
|
|
Dimensions
Dimensions
|
3.4 in (86.4 mm) case length; 7.0 mm and 7.2 mm body diameters; 3/8-24 UNF mounting thread
|
|
Weight
Weight
|
Not stated in official datasheet 172932
|
|
Total length option 20
Total length option 20
|
2.0 m (6.6 ft)
|
|
Connector option 02
Connector option 02
|
Miniature coaxial ClickLoc connector, standard cable
|
|
Linear range
Linear range
|
1.52 mm (60 mils), approximately 0.25 to 1.78 mm from target
|
|
Recommended gap
Recommended gap
|
1.0 mm (40 mils)
|
|
Scale factor
Scale factor
|
7.87 V/mm (200 mV/mil) +/-6.5 percent for a 5 m or 9 m system
|
|
Materials
Materials
|
Alumina ceramic tip; AISI 304 stainless steel case; 75 ohm FEP-insulated coaxial cable
|
|
Temperature / pressure
Temperature / pressure
|
-51 to +177 degrees C; rated to seal 34 bar (500 psi) nitrogen
|
|
Approvals option 05
Approvals option 05
|
CSA, ATEX and IECEx
|
|
Aggressive chemical service
The alumina tip and stainless case resist front-end exposure in anhydrous ammonia and other extreme-pH environments.
|
High-pressure monitoring
The probe is rated to seal 34 bar nitrogen and can be applied where pressure sealing and proximity measurement are both required.
|
|
Rotating machinery measurement
Used with a 3300 Proximitor Sensor and extension cable for non-contact shaft position and vibration monitoring.
|
Front-only exposure
The 146054 construction protects the front end; the rear of the probe is not sealed and must remain away from destructive liquids and gases.
|
|
Sensing tip
Sensing tip
|
Alumina ceramic cap bonded to the metal case and helium leak-tested for a hermetic front-end interface.
|
|
Probe case
Probe case
|
AISI 304 stainless steel with 3/8-24 UNF 2A mounting threads and a 3.4 in ordered case length.
|
|
Cable
Cable
|
2.0 m, 75 ohm coaxial FEP-insulated standard probe cable.
|
|
Connector
Connector
|
Miniature coaxial ClickLoc connector; corrosion-resistant gold-plated connector family architecture.
|
|
01
|
Protect the unsealed rear
Do not expose the rear of the 146054 probe to water, ammonia solutions, hydrogen sulfide or other destructive environments.
|
|
02
|
Respect thread engagement
Maximum thread engagement for the 3/8-24 case is 0.563 in; excessive engagement may cause binding.
|
|
03
|
Gap electrically
Use the recommended 1.0 mm gap and avoid mechanical contact between the ceramic tip and the target surface.
|
|
04
|
Check monitor configuration
The ceramic-capped probe curve is shifted relative to a standard 3300 XL probe, so verify the monitor lower OK limit and system setup.
|
|
146054
146054
|
3300 ceramic-capped probe, 3/8-24 UNF thread, without armor.
|
|
34
34
|
3.4 in overall case length.
|
|
20
20
|
2.0 m (6.6 ft) total probe length.
|
|
02
02
|
Miniature coaxial ClickLoc connector with standard cable.
|
|
05
05
|
CSA, ATEX and IECEx approvals.
|
|
FRMC2000
|
6ES7326-1BK02-0AB0
|
EXB-REL8
|
|
2250-R5D6S1
|
SB-3R-TC
|
ACHILLES-NGFW-300-2-R3B
|
|
JZ10-11-T10
|
R4410-WT
|
TM3AI8
|
|
MX-D15Di-Sec
|
NC3MD-LX
|
EL900-AN-1-A
|
|
EN300
|
LTMR08MFM
|
N31FA-N311310-1
|
|
PWA79522-01P
|
4910274
|
IGS-9812GP
|
|
CPM-51-A1V56-I2NN-AD
|
SIR88N
|
2X400W
|
|
ME3011C
|
CRT341
|
Lbb4115/00
|
|
LC1D40008F7
|
RS232-DCE
|
OTM1000
|
|
USB-I485
|
RFM96W
|
WR3910-894
|
|
1757-SRC1
|
BW2334
|
NC-300D-SL2
|
|
7266A
|
L-72
|
SATELLINE-3ASD
|
|
MA520
|
SR2E201BD
|
AEA4212PB00
|
|
AX-DIM4-MI5
|
KFD2-STC4-Ex120
|
T-ASH-G2-500
|
|
041764
|
PX145
|
A104-VGA/512K
|
|
SPM6040
|
2811297
|
BMXDDI1602
|
|
7000-5201-1
|
MODG2-12LC-SM-PT
|
EPACK-1PH
|
|
ABHW-4B
|
3AL78836ADAB
|
BG20
|
|
3RV1021-1JA15
|
1418M-EOU-1002-SFP-PSE
|
P32LA93LSNN
|
|
8746-9-2
|
EA7-T6CL+10Y19B108
|
S4-34415
|