CONFIGURATION
40 mm case / 1.0 m lead |
INTERFACE
M30 x 2 / FluidLoc |
|
LEAD TIME
In stock |
WARRANTY
1 year |
DOCUMENTED MODEL 330851-02-000-040-10-00-05 |
SYSTEM FAMILY 3300 XL 25 MM |
PRIMARY VALUE 40 mm case / 1.0 m lead |
|
Complete model
|
330851-02-000-040-10-00-05
|
|
Product family
|
Bently Nevada 3300 XL 25 MM Transducer System
|
|
Product type
|
M30 x 2 threaded proximity probe without armor
|
|
Dimensions
|
24.3 mm tip; 27.05 mm maximum tip outside diameter; M30 x 2 thread; 40 mm case; 1.0 m total length
|
|
Weight
|
Approximately 310 g, calculated from the official 230 g minimum-case value plus 5.7 g per added millimetre for a 40 mm case
|
|
Linear range
|
12.7 mm (500 mils), approximately 0.63 to 13.33 mm
|
|
Scale factor
|
0.787 V/mm (20 mV/mil)
|
|
Frequency response
|
0 to 2.7 kHz, +0 / -3 dB
|
|
Cable
|
75 ohm triaxial PFA FluidLoc; 4.0 mm maximum outside diameter
|
|
Probe materials
|
PEEK tip; AISI 304 stainless steel case
|
|
Probe temperature
|
-35 to +200 deg C continuous; +250 deg C for less than 24 hours
|
|
Minimum bend radius
|
25.4 mm
|
|
Approval option
|
05: multiple approvals
|
|
Differential expansion
Measures rotor-to-casing movement on steam turbines where a long linear range is required. |
Harsh steam service
The 25 mm family is designed for demanding steam-turbine environments. |
|
Machine protection
Feeds a matched 3300 XL 25 mm transducer loop for continuous position monitoring. |
Large target motion
Provides a 12.7 mm linear range when installed with the correct target geometry and system components. |
|
Probe tip
24.3 mm PEEK sensing tip in a 27.05 mm maximum outside-diameter nose. |
Case and thread
AISI 304 stainless steel case with M30 x 2 thread and 40 mm case length. |
|
Cable
1.0 m, 75 ohm triaxial PFA FluidLoc cable without protective armor. |
Connector
Removable-nut FluidLoc connector for the matched 25 mm extension cable and Proximitor Sensor. |
|
01
Confirm mounting Verify the M30 x 2 mount, 40 mm case clearance and target material. |
02
Set operating gap Establish the gap inside the documented 12.7 mm linear region. |
|
03
Route the lead Protect the unarmored FluidLoc lead and maintain the 25.4 mm minimum bend radius. |
04
Match the loop Use only the correct 25 mm extension cable and Proximitor Sensor for the selected system length. |
|
330851
|
3300 XL 25 mm threaded proximity probe
|
|
02
|
M30 x 2 thread
|
|
000
|
Unthreaded length: 0 mm
|
|
040
|
Overall case length: 40 mm
|
|
10
|
Total length: 1.0 m
|
|
00
|
No armor
|
|
05
|
Multiple approvals
|
|
Bi40
|
RMBA-01
|
T775B2040
|
|
C-BUS2
|
F401
|
UE4740-22H0000
|
|
150785-PR
|
2CDG110025R0011
|
MS-4AOVC
|
|
SB522A
|
NJ20+U1+A2
|
50135122-001FRE
|
|
1747-L542
|
F430R3V10
|
Z031.408
|
|
PWD00A-400-18
|
500-033370
|
930.83/6555
|
|
6ES7231-4HD30-0XB0
|
IO111
|
PG9916
|
|
1609C43G-01
|
3BSE038226R1
|
CAMIR-8EZ
|
|
871C-DH15M30-A2
|
MMC-QR030024-02LD00A
|
211052-ad
|
|
1609C42G-01
|
PTXE6A-M
|
f430/4
|
|
7311repartidor
|
DDRC820FR-CS
|
J120-15622
|
|
LNL-MT11-485
|
SB-6BS-EU
|
1SBP260150R1001
|
|
RJ45
|
PLC-RSP-24DC/21/C1D2
|
F7105A
|
|
B3608
|
KT-1
|
CK504
|
|
CTY-C3-ADV151-M
|
S100-T
|
D40/D90X23
|
|
EL5501D8000
|
D4S-AV1115DN-3312
|
LUNA-TFT43
|
|
140-CPU-434-12A
|
1C31164G02
|
POL95U.00
|
|
12EE12-316
|
PXI-5610
|
CLMERS4N
|
|
1SVR730794R3300
|
11-PKZ
|
795-099
|
|
444-01
|
SLMO24N-S30810-Q2168-X400-1
|
WV-SC385E
|