Product Name:Interface Module
Brand Name: SIEMENS
Model Number:6DP1641-8AA
Country of Origin:GERMANY
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
SIEMENS |
Model Number: |
6DP1641-8AA |
Country of Origin: |
GERMANY |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
Delivery time in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Manufacturer |
Siemens |
|
Product Type |
Interface Module / FUM 640 |
|
Part Number |
6DP1641-8AA |
|
Series |
Siemens Teleperm M / Teleperm XP |
|
Dimensions (Varies by source) |
|
|
Weight |
Approx. 0.42kg |
|
Operating Voltage |
24 V DC |
|
Power Consumption |
≤ 1A / Max. 2.5W / Max. 1W |
|
Communication Protocol |
PROFIBUS-DP, MPI, RS-485 |
|
Communication Speed |
9.6 kbps to 12 Mbps |
|
Leistungsmerkmale |
Integrated 16-bit processor, cycle ≤1ms, 8KB RAM, supports up to 2MB data storage expansion |
|
I/O Channels |
8 input + 8 output channels (16 channels total) |
|
Number of Nodes (MPI Mode) |
Up to 32 nodes |
|
Operating Temperature |
-25°C to +60°C (or 0°C to +60°C) |
|
Storage Temperature |
-40°C to +85°C |
|
Protection Class |
IP20 |
|
Connector Type |
Bottom layer G-type 64-pin power supply/signal; top layer C-type 96-pin bus interface |
|
Certification |
CE, UL, CCC |
|
Warranty |
12 Months |
The SIEMENS 6DP1641‑8AA is an interface module within the Teleperm XP distributed control system (DCS). This 6DP1641‑8AA serves as the vital link between APF sub‑racks and FUM F sub‑racks. It facilitates the seamless transfer of process data between field equipment and the central system, utilizing PROFIBUS‑DPprotocols and handling both digital and analog signals to ensure reliable communication in industrial automation.
Process Control Systems – Integration into Teleperm XP / AS620 I&C systems
Power Generation – Interface between field devices and control systems in power plants
Chemical Processing – Reliable data exchange for critical process monitoring
Manufacturing Automation – CNC machines, robotics, and production line control
Distributed I/O Architectures – Connecting sensors, actuators, and ET200 stations via PROFIBUS‑DP
Wind Power & Renewable Energy – SCADA communication and turbine controller interfacing
± PROFIBUS‑DP & MPI multi‑protocol support
± 8 analog/digital input + 8 output channels
± 24V DC operation with low power consumption (≤2.5W)
± Built‑in diagnostic LEDs for module & channel fault indication
± High‑speed data transfer up to 12 Mbps
± Wide operating temperature range (-25°C to +60°C)
± Robust design with IP20 protection for industrial environments
Establish dedicated interface between APF (automation processor) sub‑rack and FUM F sub‑rack
Perform data exchange and signal conditioning for both digital and analog I/O
Support PROFIBUS‑DP protocol for seamless industrial communication
Monitor field devices through readback inputs with output monitoring capabilities
Provide status visualization via 24 front‑panel LEDs indicating channel status or fault conditions
Q1: What is the Siemens 6DP1641‑8AA module used for in TELEPERM XP?
A1: The Siemens 6DP1641‑8AA (IM641 / FUM 640) is a dedicated interface module that establishes signal connections between APF sub‑racks and FUM F sub‑racks within the Teleperm XP / AS620 I&C pyramid. It plays an essential role in moving process data from field devices (sensors, actuators) up to the central control system and down to the cabinet bus level.
Q2: Is the 6DP1641‑8AA still in production by Siemens?
A2: No, the Teleperm M system and its associated modules, including the 6DP1641‑8AA FUM 640 interface module, have been discontinued. However, refurbished units or surplus stock may still be available from specialized third‑party vendors.
Q3: What types of signals does the Siemens 6DP1641‑8AA support?
A3: The SIEMENS 6DP1641‑8AA supports both digital and analog signal interfaces, allowing it to interface with a wide range of field devices and process equipment. Depending on configuration, it can handle digital input signals via isolated optocoupler inputs as well as analog signal conditioning for process measurement.
Q4: How do I troubleshoot the 6DP1641‑8AA interface module when faults occur?
A4: The 6DP1641‑8AA is equipped with 24 front‑panel LEDs. A steady red 5mm LED indicates a module fault, while 2mm LEDs use steady light to signal active output and 2Hz flashing light to indicate a fault on the corresponding channel【28†L1-L3】. For complex diagnostics, use the DS 670 diagnostic system or STEP 5 programming software for online diagnosis.
Q5: What is the difference between the 6DP1641‑8AA and the 6DP1661‑8AA?
A5: While both belong to the Teleperm XP interface module family, the 6DP1641‑8AA (IM641 / FUM 640) is specifically designed to mount in the FUM F sub‑rack for connecting APF sub‑racks, whereas the 6DP1661‑8AA (IM661) is an APF sub‑rack interface module that connects to FUM F sub‑racks via copper cable (max.225m). Consult your system integrator for proper selection based on your legacy infrastructure.
Inguiry Now: [email protected]