Product Name:3500/61 Temperature Modules
Brand Name:Bently Nevada
Model Number:3500/61 136711-02
Country of Origin: USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
Bently Nevada |
Model Number: |
3500/61 136711-02 |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Item |
Description |
|
Product Model |
3500/61 136711-02 |
|
Input Channels |
1 to 6 RTD / Thermocouple inputs |
|
Signal Type |
RTD / TC temperature measurement |
|
Output Type |
4–20 mA recorder output per channel |
|
System Power |
Approx. 9 W |
|
Isolation |
Channel-to-channel isolation up to 250 Vdc |
|
Dimensions |
2.3x18.5x24.1cm |
|
I/O Module Size |
241.3 × 24.4 × 99.1 mm |
|
Weight |
0.94kg |
|
Operating Temp |
-30°C to +65°C |
|
Storage Temp |
-40°C to +85°C |
|
Mounting Type |
Rack-mounted (rear slot installation) |
The 3500/61 136711-02 temperature monitoring module is designed for multi-channel industrial thermal supervision, supporting up to six RTD or thermocouple inputs for machinery protection systems. It is part of the Bently Nevada 3500 series and is widely used for reliable process temperature acquisition in critical industrial environments.
The module conditions incoming RTD/TC signals and continuously compares them against user-defined alarm thresholds. When paired with the 3500 rack configuration system, the 3500/61 enables flexible setup of mixed sensor types and supports recorder outputs for each monitoring channel, providing enhanced visibility of machine thermal behavior.
Compared with standard temperature modules, the 3500/61 136711-02 offers improved integration for predictive maintenance and real-time monitoring applications. It is suitable for redundant rack configurations and industrial automation systems requiring stable, high-accuracy temperature data acquisition.
Q1: What sensors are compatible with the 3500/61 136711-02?
A1: It supports both RTD and thermocouple temperature sensors.
Q2: How many channels can this module handle?
A2: The module supports up to six independent input channels.
Q3: Does the 3500/61 provide output signals?
A3: Yes, it provides 4–20 mA recorder outputs for each channel.
Q4: Can it be used in redundant systems?
A4: Yes, it is compatible with Triple Modular Redundant (TMR) configurations.
Q5: Is channel isolation available?
A5: Yes, isolated versions offer up to 250 Vdc channel-to-channel isolation.
| Number | Describe |
|---|---|
| 163179-02 | 3500/61 temperature monitor module with integrated recorder output for multi-channel industrial temperature monitoring applications |
| 133819-02 | 3500/61 RTD/TC non-isolated I/O module with internal terminations for flexible temperature signal input configuration |
| 133827-02 | 3500/61 RTD/TC non-isolated I/O module with external terminations for simplified field wiring and installation |
| 133835-02 | 3500/61 TC isolated I/O module with internal terminations providing channel isolation for improved signal integrity |
| 133843-02 | 3500/61 TC isolated I/O module with external terminations designed for secure thermocouple input wiring in industrial environments |
| 133892-01 | 3500/61 recorder output external termination block with terminal strip connectors for signal output distribution |
| 133900-01 | 3500/61 recorder output external termination block with Euro-style connectors for standardized industrial wiring integration |
| 136711-02 | 3500/61 RTD/TC I/O module with internal barriers and internal terminations (non-isolated configuration) for temperature monitoring systems |