| Sales | Phone/Whatsapp | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model | PR6423/105-141 CON041 |
|---|---|
| Sensor Model | PR6423/105-141 |
| Converter Model | CON041 |
| Sensor System | Eddy Current Displacement Transducer |
| Probe Diameter | 8 mm |
| Measurement Method | Non-contact eddy current |
| Static Measuring Range | ±1.0 mm |
| Dynamic Measuring Range | 0 to 500 µm |
| Recommended Dynamic Range | 50 to 500 µm |
| Sensitivity | 8 V/mm |
| Target Material | Electrically conducting steel, cylindrical shaft |
| Recommended Target Surface Diameter | 25 mm or greater |
| Peripheral Shaft Speed | 0 to 2500 m/s |
| Shaft Diameter | Greater than 25 mm |
| Nominal Gap | 1.5 mm |
| Measuring Error After Calibration | Less than ±1% linearity error |
| Zero-Point Temperature Error | 200 mV / 100 K |
| Sensitivity Temperature Error | Less than 2% / 100 K |
| Long-Term Drift | 0.3% maximum |
| Supply Voltage Influence | Less than 20 mV/V |
| Sensor Operating Temperature | -35 to +180°C; short-term up to +200°C for 5 hours |
| Sensor Storage Temperature | -40 to +70°C |
| Sleeve Thread | 3/8"-24 UNF-2A |
| Sleeve Length | 75 mm |
| Armored Cable | Without |
| Adapter Plug at 1 m | Without |
| Total Cable Length | 10 m |
| Cable End | Blunt cut cable end for converter |
| Maximum Cable Temperature | +80°C |
| Converter Supply Voltage | -23 to -32 V (-4 to -20 V output); -21 to -32 V (-2 to -18 V output) |
| Converter Output Range | -2 to -18 V or -4 to -20 V |
| Converter Frequency Range | 0 to 20,000 Hz (-3 dB) |
| Converter Rise Time | Less than 15 µs |
| Converter Protection Class | IP20 |
| Converter Connection | Screw terminal, maximum 1.5 mm² with wire-end sleeves |
| Minimum Order Quantity | 1 Piece |
|---|---|
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
PR6423/105-141 CON041 is an Emerson EPRO 8 mm eddy current measuring chain for non-contact shaft displacement and vibration monitoring. The exact PR6423 sensor configuration uses a 3/8"-24 UNF-2A thread, a 75 mm sleeve and a 10 m unarmored cable. Its blunt-cut cable end connects directly to the screw terminals of the CON041 DIN-rail signal converter. The calibrated chain provides a 2.0 mm static measuring range with 8 V/mm sensitivity and supports a selectable -2 to -18 V or -4 to -20 V output. Its 0 to 20 kHz converter bandwidth supports both slow position changes and dynamic shaft-motion signals.
PR6423/105-141 CON041 is designed for critical rotating machinery where reliable radial vibration, axial displacement, eccentricity, position or speed-related monitoring is required. The non-contact sensing principle avoids mechanical loading of the shaft and helps preserve signal stability in continuous operation. Its exact suffix identifies the mounting thread, sleeve, cable construction and cable termination needed for replacement planning. The open cable end and CON041 screw-terminal interface provide a practical configuration for panel integration. This Emerson EPRO eddy current sensor system is suited to turbines, compressors, pumps, fans, motors and other rotating equipment condition-monitoring applications.
| DIN-2MC2 6501745 | 1771-IC | 0330-0012 |
| 009SMA2 | R6010 | 46904 KHA6-SH-Ex1 |
| FK-PZ3 | ABB N3-65-440S | GSS SDA 17/17 |
| MK8050GACY HDD2E46 | 026590 RS485 | TM3DI8 |
| 1606-XLS480EE | KDM-R2 | 2CDG110167R0011 |
| 330100-90-03 | PM8M22 | ABE7 R16S210 |
| 552854-506 | 089475/22-08-51 | EIR505 |
| IS5110-00 825-0059-1R | QSWE-4BN-AW | 580-034885-2 |
| MX321-2 E000-23212 | RCT016NAA | AAM51-S2 |
| 1768-ENBT/A PN-14845 | PBT-PA-BMS-SC3B-XL | 6AG1241-1AH32-2XB0 |
| 285-04704 | 701150/8-01-0253-2001-25/005 | 88974031 CB20 |
| 520AOD01 1KGT024500R0001 | SB-DIM46c2A-DN | Jan-26 |
| KCD2-SCD-EX1 | LEM-320 | HR3D28KUTC3BB |