bently nevada 3300 xl 8 mm 330104 00 05 10 11 05 armored fluidloc proximity probe-0

Bently Nevada Sensor

Home >  Products >  BENTLY NEVADA >  Bently Nevada Sensor

Bently Nevada 3300 XL 8 mm 330104-00-05-10-11-05 Armored FluidLoc Proximity Probe

Bently Nevada 3300 XL 8 mm Armored FluidLoc Proximity Probe
Complete Model
330104-00-05-10-11-05
Official Product Description
Bently Nevada 330104-00-05-10-11-05 metric 3300 XL 8 mm armored proximity probe with M10x1 thread, 0 mm unthreaded length, 50 mm case, 1.0 m FluidLoc cable, protected ClickLoc connector and approvals.
CORE FEATURE: One-metre armored M10x1 proximity probe with FluidLoc cable and approved protected connection.
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications & Features
  • Connections
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
330104-00-05-10-11-05 is a metric Bently Nevada 3300 XL 8 mm proximity probe with an M10x1 case thread and stainless-steel armor.
The complete code specifies 0 mm unthreaded length, 50 mm overall case length, 1.0 m total length, a protected miniature coaxial ClickLoc connector, FluidLoc cable and CSA, ATEX and IECEx approvals.
When used in a matched 3300 XL 8 mm transducer system, the published linear range is 2.0 mm and the nominal scale factor is 7.87 V/mm.

Technical Data

Complete model
330104-00-05-10-11-05
Brand
Bently Nevada
Product family
3300 XL 8 mm Proximity Transducer System
Product type
Metric armored proximity probe
Probe thread
M10x1
Unthreaded length
0 mm
Overall case length
50 mm
Total length
1.0 m (3.3 ft)
Connector and cable
Miniature coaxial ClickLoc connector with connector protector and FluidLoc cable
Armor
Flexible AISI 302 or 304 stainless steel with FEP outer jacket
Probe dc resistance
7.59 plus or minus 0.50 ohm for the 1.0 m probe
Linear range
2.0 mm (80 mils), approximately 0.25 to 2.3 mm from the target
Recommended gap
1.27 mm (50 mils) for published system specifications
Scale factor
7.87 V/mm (200 mV/mil) nominal
System power
-17.5 to -26 Vdc, 12 mA maximum at the Proximitor Sensor
Probe materials
PPS tip and AISI 303 or 304 stainless-steel case
Operating temperature
-52 to +177 degrees C for the standard probe
Storage temperature
-52 to +177 degrees C for the standard probe
Minimum cable bend radius
25.4 mm (1.0 in)
Maximum thread engagement
15 mm for M10x1
Recommended probe-case torque
11.2 N m; 7.5 N m when only the first three threads are engaged
Agency approval option
05 - CSA, ATEX and IECEx approvals
Dimensions
8.0 mm probe-tip diameter; 0 mm unthreaded length; 50 mm case; 1.0 m total length; cable 3.94 mm outside diameter for FluidLoc; armor 7.67 mm outside diameter; connector 7.24 mm outside diameter
Weight
Published typical probe weight is 323 g/m; the official datasheet does not state a separate exact assembled weight for this complete configuration
Official source
Baker Hughes Bently Nevada datasheet 141194 Rev. AN, pages 1, 3-13 and 35
Complete model
330104-00-05-10-11-05
Brand
Bently Nevada
Product family
3300 XL 8 mm Proximity Transducer System
Product type
Metric armored proximity probe
Probe thread
M10x1
Unthreaded length
0 mm
Overall case length
50 mm
Total length
1.0 m (3.3 ft)
Connector and cable
Miniature coaxial ClickLoc connector with connector protector and FluidLoc cable
Armor
Flexible AISI 302 or 304 stainless steel with FEP outer jacket
Probe dc resistance
7.59 plus or minus 0.50 ohm for the 1.0 m probe
Linear range
2.0 mm (80 mils), approximately 0.25 to 2.3 mm from the target
Recommended gap
1.27 mm (50 mils) for published system specifications
Scale factor
7.87 V/mm (200 mV/mil) nominal
System power
-17.5 to -26 Vdc, 12 mA maximum at the Proximitor Sensor
Probe materials
PPS tip and AISI 303 or 304 stainless-steel case
Operating temperature
-52 to +177 degrees C for the standard probe
Storage temperature
-52 to +177 degrees C for the standard probe
Minimum cable bend radius
25.4 mm (1.0 in)
Maximum thread engagement
15 mm for M10x1
Recommended probe-case torque
11.2 N m; 7.5 N m when only the first three threads are engaged
Agency approval option
05 - CSA, ATEX and IECEx approvals
Dimensions
8.0 mm probe-tip diameter; 0 mm unthreaded length; 50 mm case; 1.0 m total length; cable 3.94 mm outside diameter for FluidLoc; armor 7.67 mm outside diameter; connector 7.24 mm outside diameter
Weight
Published typical probe weight is 323 g/m; the official datasheet does not state a separate exact assembled weight for this complete configuration
Official source
Baker Hughes Bently Nevada datasheet 141194 Rev. AN, pages 1, 3-13 and 35

Inquiry

Applications & Features

Armored lead
Flexible stainless-steel armor protects the one-metre probe lead from mechanical damage.
FluidLoc cable
The selected FluidLoc construction limits fluid migration through the probe cable.
Protected ClickLoc
Option 11 combines the miniature ClickLoc connector with its connector protector.
Metric mounting
The M10x1 case provides the published metric mounting configuration.

Connections

Probe connector
Miniature coaxial ClickLoc connector with connector protector
Probe cable
FluidLoc 75 ohm triaxial cable, 1.0 m total probe length
Mechanical protection
Flexible stainless-steel armor with FEP outer jacket
Electronics
Use with a matched 3300 XL 8 mm Proximitor Sensor system
One-metre system
A one-metre system uses the probe without an extension cable

Installation

01 - Verify the complete code
Match 330104-00-05-10-11-05 on the quotation, probe label, packaging and order record.
02 - Prepare the mounting
Provide an M10x1 mounting thread and keep thread engagement at or below the published 15 mm maximum.
03 - Apply correct torque
Use 11.2 N m for normal engagement or 7.5 N m when only the first three threads are engaged.
04 - Set the measurement gap
Establish the published 1.27 mm reference gap and verify the matched-system output before commissioning.
05 - Route the armored lead
Maintain at least 25.4 mm bend radius and prevent crushing, twisting or over-tensioning of the armor.

Environment

Temperature
Standard probe operating and storage range is -52 to +177 degrees C.
Low-temperature caution
Exposure below -34 degrees C may cause premature failure of the pressure seal.
Probe materials
PPS sensing tip with an AISI 303 or 304 stainless-steel case.
Armor material
Flexible AISI 302 or 304 stainless steel with an FEP outer jacket.
Pressure sealing
A Viton O-ring seals differential pressure; probes are not pressure-tested before shipment.
Approvals
Suffix 05 specifies CSA, ATEX and IECEx approvals.

FAQ

Q1. How can the exact quoted 330104-00-05-10-11-05 be verified?
Match the full code on the quotation, label and packaging. Confirm the M10x1 thread, armor, 0 mm unthreaded length, 50 mm case, 1.0 m FluidLoc cable, protected ClickLoc connector and 05 approval suffix.
Q2. How can New, Used or Refurbished condition be distinguished?
Request current date-marked photos of the 8 mm tip, M10x1 thread, 50 mm case, full armored lead, connector protector and label. Check for thread wear, crushed armor, repaired cable, contamination or altered labels.
Q3. How should supplier legality and reliability be checked?
Verify the legal entity, registered address, payment beneficiary and traceable contact. The written offer should state Bently Nevada, complete model 330104-00-05-10-11-05, condition, quantity and return terms.
Q4. Which specifications must engineering confirm before purchase?
Confirm the M10x1 thread, 0 mm unthreaded length, 50 mm case, 1.0 m FluidLoc cable, stainless-steel armor, protected ClickLoc connection, 2.0 mm range and matched Proximitor compatibility.
Q5. What physical evidence should be requested before payment?
Ask for dated photos showing the complete label, 8 mm tip, M10x1 case, entire armored lead, protected connector, approval markings and original packaging, plus a measurement of the 1.0 m total length.
Q6. Can another 330104 suffix replace 330104-00-05-10-11-05?
Not automatically. Suffixes change unthreaded length, case length, total length, connector protection, cable type and approvals. Engineering must approve every changed position.

Recommend Models

ZE-Q-2S
031SA4004011Z
VL-690393-1 N16645
NKTU11-14
ZB4BVB3
ABB NBMNAAABNEC1BNN1XF
1285-W
MS4-FRM-FRZ
PRD30-25DN
VFS4300
ST-DI-024-16
IS220PDIOH1B
M061-FC08
KGJP2107 7555GR07
WMZH1C15
5SJ4116-6HG40
HUS723020ALS640
82A-BC-000-TM-DAAP-1DA
B&R X20BM11
30-6M/S90-SP
EX950A-10
TK-E02 TK22EW-X
7SS52 7SS5231-5CA01-0AA1/GG
FCN-360 BK0-C4127H08
OMICRON ,CMC 430
5SY4514-8
42MTB-5004
2116-1291
7SS52 7ss5231-5ca01-1aa1
33102430601
C200H-ID212
BFD71S 765A827G01
RCMT32.5-1A
4XD250B PN:580243
CS7X PC59-00101-07
RXE2N0F7H132A
BOSS50 PL-5 B01-NN
OPDS-MP-0155-I1
Ti300
N72408
C47 1-1/4
RJ45S 860-5M
IC693ALG221B
HBL2310SW
WMZT3D02
743040115
700-HB32Z12
MT31.DK1ADNBX
UM5ACG-H5R
NBN15-F11-E2
GE P112-6053
117442
6ES71936BP200DA0
6779-9091 HD2-DM-B
HC-B 24-EBUS
7500-0006-00000
1275225
T-51 8214
DC60S3-B
AIF01A A03B-0807-C011

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000