Honeywell 10004/I/I Safety Manager RS-422/485 Communication Module

SAFETY MANAGER SERIAL LINK
Product Name:
Safety Manager RS-422/485 Communication Module
Brand Name:
Honeywell
Model Number:
10004/I/I
Place of Origin:
USA
Warranty:
12 Months
Direct product enquiry
Whatsapp:
+86 18020776782
  • Overview
  • Specifications
  • Commercial Terms
  • Description
  • Serial Data Routing
  • Safety Manager Integration
  • FAQ
  • About Company
  • Other Products
  • Recommended Products
Sales Email Phone/Whatsapp
Jim Pei [email protected] +86 18020776782

Specifications

Model 10004/I/I
Product Family Safety Manager
Product Type RS-422/485 communication module
Honeywell Part Number 3400195
Alternative Identifier 05602
Communication Interfaces 1
Interface Standard RS-422 / RS-485
System Platform Safety Manager
Module Function Serial communication
Lifecycle Obsolete
Replacement Planning Exact interface and project review required

Commercial Terms

Minimum Order Quantity 1 Piece
Price Contact for Jim
Packaging Details Original new Factory Sealed
Delivery Time 3–7 Days
Payment Terms T/T
Shipping Method DHL / FedEx / UPS / TNT
Supply Ability Brand new, In Stock

Description

Designed as a Honeywell RS-422/485 communication module, 10004/I/I belongs to the Safety Manager platform. It provides one RS-422/485 communication interface for the Safety Manager platform. The model-specific arrangement keeps serial field communication separate from the safety-logic execution path. Its installed interface uses the exact 10004/I/I identity and Honeywell part number 3400195 for replacement control. These characteristics define the exact hardware boundary that must be matched when the component is sourced for an existing system.

In service, 10004/I/I supports serial device integration while maintaining the documented legacy link continuity path. The component is especially relevant where project-controlled replacement must remain predictable after service. Before removal, technicians should record the host location, connector orientation and project settings that govern communication troubleshooting. Requires the installed baud rate, wiring topology and project communication settings to be preserved. A controlled functional test should then confirm the restored path before the equipment returns to normal operation.

Serial Data Routing

CONTROLLED SERIAL COMMUNICATION
One configurable serial interface links legacy devices without moving their traffic into the safety-logic execution path.
01 · PORT
RS-422 / RS-485The module provides one configurable serial communication interface.
02 · BOUNDARY
Separated data pathSerial field traffic remains separate from Safety Manager safety-logic execution.
03 · PART CONTROL
Honeywell 3400195The manufacturer part number anchors exact-spare verification.
04 · ALTERNATE ID
05602This identifier can support nameplate and inventory reconciliation.
05 · HOST
Safety ManagerThe module belongs to the Honeywell Safety Manager platform.
06 · COMMISSIONING
Preserve link settingsBaud rate, wiring topology and project communication parameters must be retained.

Safety Manager Integration

01 · DEVICE LINKSerial device integrationConnects the installed RS-422 or RS-485 device path to Safety Manager.
02 · CONTINUITYLegacy link retentionKeeps an established serial connection available during controlled lifecycle service.
03 · PROJECTConfiguration-led exchangeReplacement depends on the communication values stored in the application project.
04 · DIAGNOSISLink fault isolationPort status, wiring polarity and communication framing can be checked as separate fault domains.
WIRING DECISIONConfirm whether the installed circuit uses RS-422 or RS-485 before moving conductors.
RETURN-TO-SERVICEProve stable message exchange at the documented baud rate before declaring the link available.

FAQ

Q1. Does 10004/I/I provide more than one serial communication interface?No. The module provides one RS-422/RS-485 interface, so the existing device path must fit that single-port arrangement.
Q2. How is serial traffic handled by 10004/I/I inside Safety Manager?The serial field-communication path is kept separate from the safety-logic execution path.
Q3. Which Honeywell part number should be checked against 10004/I/I?Use Honeywell part number 3400195 and reconcile the alternate identifier 05602 with the installed nameplate.
Q4. What link settings matter when commissioning 10004/I/I after exchange?Restore the installed baud rate, wiring topology and project communication parameters before testing message transfer.
Q5. Can an RS-422 circuit be moved to 10004/I/I as though it were RS-485?Not without checking the field wiring. The selected electrical mode, conductor arrangement and polarity must match the existing circuit.
Q6. What evidence is most useful when a 10004/I/I link stops communicating?Record port status, terminal wiring, device address, framing values and the project settings used by the affected serial channel.

About Company

Apter Power international sourcing office team
A modern workspace supporting coordinated international sourcing and customer communication.
Years of Global ExperienceWith 20+ years of industry experience, we serve customers worldwide and have built long-term relationships across the UK, Russia, UAE, India, Venezuela, and more.
Professional Support TeamOur experienced team provides reliable pre-sales and after-sales support, helping customers select suitable products and resolve purchasing concerns.
Wide Range of BrandsWe supply leading automation brands covering PLCs, DCS, I/O modules, drives, motors, power supplies, communication modules, and more.
Large In-Stock InventoryA wide range of products is available from stock, including discontinued, obsolete, and hard-to-find parts, helping reduce sourcing time.
Apter Power warehouse product inspection team
Hands-on warehouse inspection helps verify product condition before dispatch.
Honesty & TrustWe value long-term cooperation and treat every customer with honesty, respect, responsibility, and care.
Your Trusted Automation PartnerFrom a single replacement part to complete automation projects, we are ready to support your needs and build a long-term partnership.

Other Products

K9403TR-03 1532-Y8030 HNWG50086423-006
1756-cnbr/E Artikel3-2000U040400 C65-MW、LNL-C65-MW
448B16001 KFD2-CRG2-EX1D NS-SDW-210
QND-6082R MP2HI3HCGL HPBYB8A 316SS-PTFE
PXC22.D ABE7 P16T334 R911172296 SLC-A-UE12-2FG3D0
2250-R5D6S1 ABB 1SBP260181R1001 CP410M DL50F/S176
MS-16DI ABB TB/U6.5.1-CG ABB AI835A 3BSE051306R1
VFF5 C2N-MNETGW L5508RVF
HRI-B4/8L AMRAB152 T5930 AT-MC102XL-40 990-000445-40
M-EDC-PS1012CB5F5 PCO5000000AS0 1763-L16BWA
SS-4BHT-72 EXD5314CE PRO 250
ABB PM571 / 1SAP130100R0170 Rh390 SG200-50
HS2128PCB TSW-552-BS LCNP4 51403299-200

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000