allen bradley controllogix 5570 1756 l75 32 mb controller-0

Allen Bradley ContrlLogix

Home >  Products >  ROCKWELL >  Allen Bradley ContrlLogix

Allen-Bradley ControlLogix 5570 1756-L75 32 MB Controller with USB and SD Memory | Original New

ALLEN-BRADLEY | CONTROLLOGIX 5570
1756-L75
ControlLogix 5570 Controller with 32 MB Memory, USB Port and Alphanumeric Display
32 MB USER MEMORY | 0.98 MB I/O MEMORY | USB 2.0 | PREINSTALLED 1 GB SD CARD | 100 MOTION AXES
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Functions
  • Interfaces
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
ALLEN-BRADLEY CONTROLLOGIX 5570
1756-L75 32 MB Controller
A chassis-based programmable automation controller for high-capacity logic, I/O, motion and redundant ControlLogix applications.
Memory
32 MB user memory
0.98 MB I/O memory
Local Access
USB 2.0 full speed
temporary programming port
Storage
1 GB 1784-SD1
ships preinstalled
Selection summary
The exact catalog number 1756-L75 identifies the 32 MB ControlLogix 5570 standard controller. It supports up to 128,000 digital I/O, 4,000 analog I/O, 500 controller connections and 100 motion axes. Network access is provided through compatible ControlLogix communication modules; the controller itself does not include an embedded network port.
Official references
Rockwell Automation product page: 1756-L75 | ControlLogix 32 MB Controller.
Technical data: publication 1756-TD001W-EN-P, ControlLogix and GuardLogix Controllers Technical Data, pages 54-55.
User manual: publication 1756-UM001.

Technical Data

Complete model
1756-L75
Product family
Allen-Bradley ControlLogix 5570
Product type
Chassis-based programmable automation controller
Official description
ControlLogix 5570 controller with 32 MB memory, USB port and 4-character alphanumeric display
User memory
32 MB
I/O memory
0.98 MB
Nonvolatile memory
1 GB Secure Digital card 1784-SD1, preinstalled
Digital I/O maximum
128,000
Analog I/O maximum
4,000
Motion axes supported
100
Local programming port
1 USB; USB 2.0 full speed, 12 Mbps
Current draw
5 mA at 1.2V DC; 800 mA at 5.1V DC
Power dissipation
2.5 W
Isolation voltage
30V continuous, basic insulation, USB port to backplane
Dimensions
One ControlLogix chassis slot; physical envelope defined by the official product drawing (DXF)
Weight
Approximately 0.25 kg (0.55 lb)
Mounting
ControlLogix chassis, any slot
Operating temperature
0 to 60 C (32 to 140 F)
Storage temperature
-40 to 85 C (-40 to 185 F)
Relative humidity
5 to 95%, noncondensing
Enclosure rating
None; open-style equipment
Certifications
CE, UL Listed, UL Listed Hazardous, ATEX, IECEx, RCM, KC and other product-specific approvals listed by Rockwell Automation

Functions

High-capacity control
32 MB of user memory and 0.98 MB of I/O memory support large logic, data and documentation requirements in ControlLogix applications.
Task and program organization
Supports 32 controller tasks and, with current Logix Designer revisions, up to 1000 programs per task for structured application design.
Motion and redundancy
Supports integrated motion through compatible SERCOS, analog and EtherNet/IP motion interfaces, with full controller redundancy support.
Programming languages
Relay ladder logic, structured text, function block diagram and sequential function chart are supported in the Logix environment.

Interfaces

Local USB interface
One USB 2.0 full-speed port is provided for temporary programming, configuration, firmware update and online edits.
Network architecture
No embedded network port is present. EtherNet/IP, ControlNet, DeviceNet, Data Highway Plus, Remote I/O, SERCOS and third-party networks are implemented through compatible ControlLogix communication modules.
Controller connections
Up to 500 controller connections are supported. Per-network capacity depends on the selected communication module.
Removable storage
The preinstalled 1784-SD1 Secure Digital card provides 1 GB of nonvolatile storage for controller projects and firmware operations.

Installation

Chassis mounting
Install the controller in one slot of a compatible 1756 ControlLogix chassis. The module may occupy any chassis slot allowed by the system design.
Power coordination
Verify the chassis power supply and power budget for 5 mA at 1.2V DC and 800 mA at 5.1V DC before installation.
System compatibility
Choose compatible 1756 chassis, power supply, communication and motion modules, then confirm firmware and Studio 5000 Logix Designer compatibility for the complete system.
Commissioning
Use the USB port only for temporary local engineering. Rockwell Automation states that the USB port is not intended for permanent connection and must not be used in hazardous locations.

Environment

Operating range
0 to 60 C
5 to 95% RH, noncondensing
Nonoperating range
-40 to 85 C
Open-style equipment
Environmental design
The standard 1756-L75 is not conformal coated. Install it inside a suitable enclosure that provides the required environmental protection for the application.
Compliance framework
Official specifications reference IEC 60068 environmental testing and IEC 61000 immunity/emissions standards. Product approvals listed by Rockwell Automation include CE, UL, ATEX, IECEx, RCM and KC; verify the markings on the supplied unit.

FAQ

Q1. How can a buyer verify that the quoted controller is the exact 1756-L75?
Require a clear label photo showing catalog number 1756-L75 and series, then match it to the official description: ControlLogix 5570 controller with 32 MB user memory, 0.98 MB I/O memory, USB port and SD storage.
Q2. How can New, Used or Refurbished condition be distinguished?
Ask for current photos of the enclosure, label, USB cover, display, backplane connector and energy-storage-module area. New condition should be supported by intact packaging and consistent serial and date-code evidence, not only a written claim.
Q3. How should the supplier be checked before purchase?
Verify the legal company name, business registration, bank beneficiary, physical contact details and a traceable sales history. Ask the supplier to demonstrate possession of the exact 1756-L75 shown in the quotation.
Q4. Which specifications should an engineer verify before ordering?
Confirm 32 MB user memory, 0.98 MB I/O memory, one-slot ControlLogix chassis installation, USB local programming, 1784-SD1 storage, required communication modules, firmware revision, chassis power budget and 0 to 60 C operating range.
Q5. What physical evidence should be requested before payment?
Request timestamped photos or video showing the 1756-L75 label, serial number, series, 4-character display, USB port, SD card, backplane connector, packaging and any included energy storage module.
Q6. Can a similar 1756-L7x suffix replace 1756-L75?
Not automatically. Other 1756-L7x controllers differ in user memory, coating, motion or safety capability and lifecycle. A substitution requires engineering review of memory capacity, firmware, redundancy, motion, chassis and certification requirements.

Recommend Models

6ES7223-1PL32-0XB0
6ES7288-1CR30-0AA0
VI702
1756-L83ES
TU844
6ES7288-2DT16-0AA0
6ES7231-4HD32-0XB0
6ES7231-5QD32-0XB0
6ES7222-1HH32-0XB0
DO890
DI525
DI524
A2FV70S
6ES7234-4HE32-0XB0
AAB141
6ES7221-3AD30-0XB0
6ES7512-1DK01-0AB0
6ES7217-1BG40-0XB0
SS832
VE3051C3
6ES7288-1CR60-0AA0
6ES7517-3FP00-0AB0
5069-L340ER
1756-L81EP
SM560-S
ATD5A
1756-IF16
1756-L905TS
VE4005S2B2
AI523
6ED1052-1FB08-0BA2
6ES7215-1BG40-0XB0
ATSS3D
TU810V1
PM5032-T-ETH
6ES7288-1CR40-0AA0
5069-L310ERM
CC-TAIX01
6ES7288-2DT08-0AA0
DA502
6ES7232-4HD32-0XB0
6ES7516-3AN02-0AB0
AFV30D
VE4035S2B4
KJ2006X1-BK1
6ED1055-1NB10-0BA2
EB402
6ES7232-4HA30-0XB0
CC-PUIO01
CI853K01
CC-PDIL01
AAP849
VE3051C1
DI830
6ED1055-4MH08-0BA1
KJ3222X1-BA1
VE4002S1T1B1
6ES7417-4HT14-0AB0
VI701
CC-PCNT02

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000