pm5052 r eth-0

ABB Advant OCS

Home >  Products >  ABB >  ABB Advant OCS

ABB AC500-eCo V3 PM5052-R-ETH Standard PLC CPU with Relay Outputs and Ethernet | Original New

ABB AC500-eCo V3
PM5052-R-ETH
Standard PLC CPU, 12 DI, 6 relay DO, 2 configurable DC and Ethernet
ONBOARD I/O
12 DI / 6 relay DO / 2 DC
EXPANSION
I/O bus + 3 option slots
DIMENSIONS
78 x 142 x 73.05 mm
WEIGHT
Approx. 273 g
LEAD TIME
In stock
WARRANTY
1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications
  • Capacity & Technology
  • Compatibility
  • Lifecycle
  • FAQ
  • Recommend Models
  • Recommended Products

Technical Data

TECHNICAL DATA
Complete model
PM5052-R-ETH
Product family
ABB AC500-eCo V3
Product type
Standard CPU / programmable logic controller
Power supply
24 V DC via removable 3-pin terminal
Current consumption
400 mA maximum
Power dissipation
9.2 W maximum, relay version
Digital inputs
12 onboard 24 V DC inputs
Digital outputs
6 normally-open relay outputs
Relay rating
2 A per channel; 24 V DC or 100 to 240 V AC rated
Configurable channels
2 configurable 24 V DC inputs/outputs
High-speed inputs
4 counters up to 100 kHz; encoder functions up to 200 kHz
Ethernet interfaces
1
I/O bus
Available; up to 10 compatible I/O modules
Option-board slots
3
DRAM
128 MB
Maximum downloadable application
7 MB; 768 KB for user program code and dynamically allocated data
Memory card
Micro memory card slot
Mounting position
Horizontal or vertical
Dimensions (W x H x D)
78 x 142 x 73.05 mm housing; drawing shows 149.52 mm maximum height
Weight
Approx. 273 g, relay version

Applications

APPLICATIONS
01 · MACHINE AND PROCESS CONTROL
Expanded relay-based automation
Twelve digital inputs, six isolated relay outputs and two configurable DC channels support medium-size control panels that switch both AC and DC field loads.
02 · MODULAR EQUIPMENT
Local I/O-bus expansion
Up to ten compatible AC500-eCo I/O modules can extend the onboard channels, allowing the CPU to coordinate distributed machine functions in a compact platform.
03 · COMMUNICATION-RICH PANELS
Three option-board positions
Three option slots provide room for approved serial, CAN and other function boards while the integrated Ethernet interface supports engineering and network services.

Capacity & Technology

CAPACITY & TECHNOLOGY
01 · APPLICATION MEMORY
7 MB maximum downloadable application
The CPU includes 128 MB DRAM and provides up to 768 KB for user program code and dynamically allocated data, offering more project capacity than PM5012 and PM5032 variants.
02 · RELAY OUTPUT BANK
Six normally-open contacts
The outputs are divided into two groups of three channels. Each channel is rated up to 2 A, and the system requires external short-circuit and overload protection.
03 · FAST ACQUISITION
Four counters up to 100 kHz
Designated 24 V DC inputs support fast counters and encoder functions up to 200 kHz, while four standard inputs can be assigned as interrupt sources.
04 · EXPANSION RESOURCES
I/O bus plus three option slots
The combination of local I/O-bus support and three option-board positions enables broader channel and communication expansion within the approved AC500-eCo architecture.

Compatibility

COMPATIBILITY
01 · ENGINEERING PLATFORM
ABB Automation Builder
Match project, firmware and hardware revision. Revision 1 devices require firmware V3.6.x or higher and Automation Builder 2.6.0 or later for updated applications.
02 · RELAY LOADS
Electrical protection and suppression
Confirm load voltage, 2 A channel current, group loading, switching frequency and external fusing. Inductive loads require suitable demagnetization or spark suppression.
03 · EXPANSION PLAN
I/O and option-board validation
Verify the selected I/O modules, station order, power budget, option-board interfaces and cabinet clearances before commissioning.

Lifecycle

LIFECYCLE
01 · PRODUCT REVISION
Active revision 1 available
ABB lists PM5052-R-ETH revision 1, part number 1SAP124100R0172, as active. The earlier R0072 revision is limited and replaced by revision 1.
02 · IDENTIFICATION
Model and revision traceability
Record PM5052-R-ETH, the complete 1SAP rubric, serial number and hardware revision on purchasing and maintenance records.
03 · COMMISSIONING
Configuration evidence
Archive the Automation Builder project, firmware, IP settings, I/O-bus station, option-board configuration and memory-card image.
04 · MAINTENANCE
Controlled relay CPU replacement
Inspect relay terminals and contact service history, then verify I/O mapping, expansion hardware, firmware and project compatibility before replacement.

FAQ

FAQ
Q1. How can the quoted CPU be verified as the exact model?
Check that the nameplate and package show PM5052-R-ETH, 24 V DC supply, 12 digital inputs, 6 relay outputs, 2 configurable DC channels, one Ethernet interface and three option-board slots. Record the complete 1SAP rubric.
Q2. How can New, Used and Refurbished condition be distinguished?
Request dated photos of the sealed package, nameplate, serial number, relay terminal block, Ethernet port, option covers and rail latch. New equipment should not show wiring marks, contact-area discoloration, rail scratches, dust or relabeling.
Q3. How should a buyer assess whether the supplier is legitimate and reliable?
Verify legal registration, bank-account ownership, a traceable quotation and clear after-sales terms. Ask for a current powered video showing PM5052-R-ETH, the full 1SAP rubric, serial number and onboard I/O indication.
Q4. Which specifications should an engineer confirm before purchase?
Confirm 24 V DC supply, 12 DI, 6 normally-open relay outputs at 2 A per channel, 2 configurable DC channels, I/O-bus plan, three option slots, 7 MB application capacity, dimensions, weight and firmware compatibility.
Q5. What physical evidence should be requested before payment?
Request timestamped images of the complete nameplate, packaging seals, 25-pin I/O terminal block, Ethernet port, power connector, three option-board covers, I/O-bus connector and serial number. All documents should identify the same PM5052-R-ETH unit.
Q6. Can PM5052-T-ETH or PM5032-R-ETH be used as a substitute?
Not automatically. PM5052-T-ETH uses transistor outputs, while PM5032-R-ETH has fewer option slots and lower application capacity. Load type, terminal mapping, expansion plan and firmware must be reviewed before substitution.

Recommend Models

RECOMMEND MODEL
ECA-1 JB-4
NETCLOCK/GPS9389 P/N:1185-0017-0600
230170E
4269-596.04
3500R1B06B1Bezzz
K100MPWM0000
TA25DU 1SAZ211201R1025
2PN7321806
HCPS.9-2508W
1783-US5T
PCO3000AL0
603-528-7780
GC1600CH
PTS300-Q-DOP
1756-IA16I
JNM5-4TX/4SFP 100FX-SFP
TM3DQ32UK
T9600-TF21-1JS0
160EET
193-EC2AB
0563 0470
1AC/24VDC-20A-DN4014 / PSU1AC24VDC20ADN4014
HR3D28KUTC3BB
LFI520 RIF-R
K35131SCW
ABB SDCS-APD-2 61268570A
DP-DL01D
ABB DC541-CM 1SAP270000R0001
F02379
ABB TU842 / 3BSE020850R1
1404-M505A-DNT
9470-26-904-102
TMT112-B31BA
9150-28179-00
CUST-GRX-30C
WR3910-894
XJBO3-5928-1
ABB RXMVB 4, Rk 251 402-AP
CST 205764
MNB-V2-2 I/A
NP3X-D
BZME1-A25-BT
AC1216
3613-0001 TD-35
1C31166G01
PPC-L61T
966P
KJ2003X1-BA2 12P2093X102
050-11-10m
H4D1F1X
3500/15 125840-02
K9701PM PLC24
03652 LG-003652
052719
116-010038A GK60-2
TC810E1040
80025-551-01-R
UPC20 FG672
DVC5020
10160-1883-01

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000