Siemens 6AU1425-2AD00-0AA0 SIMOTION D425-2 DP/PN Control Unit

Product Name: SIMOTION D425-2 DP/PN Control Unit
Brand Name: Siemens
Model Number: 6AU1425-2AD00-0AA0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Description
  • Motion Integration
  • Specifications
  • Contact info
  • Commercial Term
  • About Company
  • FAQ
  • Other Products
  • Recommended Products
Drive-Based Motion Control for Multi-Axis Automation

Siemens 6AU1425-2AD00-0AA0 is a SIMOTION D425-2 DP/PN drive-based programmable motion controller in the BASIC performance class.

Selection checkpoint: Confirm the SIMOTION project, firmware, CompactFlash data, DRIVE-CLiQ topology and PROFIBUS/PROFINET assignments before commissioning a replacement controller.

Description

6AU1425-2AD00-0AA0 combines PLC and motion-control tasks for multi-axis machines. The D425-2 DP/PN platform provides DRIVE-CLiQ connections together with PROFIBUS, PROFINET, Ethernet, USB and configurable I/O for coordinated machine control.

A service replacement depends on the saved SIMOTION project and the installed drive topology. Record the controller firmware, CompactFlash contents, network addresses and axis assignments before hardware is exchanged, then restore and validate the machine in controlled stages.

Motion Integration

01
Multi-axis control
Coordinate motion tasks for machines with multiple configured axes.
02
DRIVE-CLiQ links
Connect supported SINAMICS drive components through four DRIVE-CLiQ interfaces.
03
Industrial networks
Integrate PROFIBUS and PROFINET devices with documented machine addressing.
04
Project recovery
Restore the approved controller project and retained machine data after service.

Specifications

Technical parameter Value
Product type designation SIMOTION D425-2 DP/PN
Article number 6AU1425-2AD00-0AA0
Performance class BASIC Performance
Maximum axes 16
DRIVE-CLiQ interfaces 4
PROFIBUS interfaces 2
PROFINET connection 1 interface with 3 onboard ports
Additional interfaces 2 Ethernet and 2 USB
Integrated I/O 12 DI and 16 DI/DO
Rated supply voltage 24 V DC
Included hardware Dual fan / battery module and battery
Manufacturer Siemens

Contact info

Commercial Term

Quotation Payment Lead time Shipping Warranty
Contact us for current price and availability T/T or agreed terms Confirmed with the quotation DHL, FedEx, UPS or agreed freight 12 months

About Company

SupplyPLCs supports exact-model review, product-condition confirmation and responsive industrial automation sourcing.
Share the complete order number, installed-system context and destination. Our team will coordinate availability, shipment options and available official product documentation.

FAQ

Q1
How can I confirm that 6AU1425-2AD00-0AA0 is compatible with the SIMOTION project in my machine?
Compare the exact D425-2 DP/PN order number, controller firmware, SCOUT project version, CompactFlash data and configured axis count. Review all technology objects and drive assignments before downloading anything to the replacement unit.
Q2
What should I preserve before replacing 6AU1425-2AD00-0AA0 during a planned outage?
Archive the complete SIMOTION project and record firmware, licenses, retained data, network addresses and the DRIVE-CLiQ topology. Keep a verified copy of the CompactFlash contents and document every connected drive component before disconnection.
Q3
Why can 6AU1425-2AD00-0AA0 start but fail to recognize a SINAMICS drive after restoration?
Compare the physical DRIVE-CLiQ order with the saved topology and inspect connector seating before changing project data. A missing or differently ordered drive component can prevent the restored configuration from matching the machine.
Q4
How should I investigate a PROFINET communication fault after installing 6AU1425-2AD00-0AA0?
Check the assigned device name, IP settings, port connections and controller role against the archived project. Diagnose one network segment at a time and preserve the working motion configuration while isolating the communication path.
Q5
What maintenance checks are important when the fan or battery alarm appears on 6AU1425-2AD00-0AA0?
Follow the Siemens service procedure for the supplied dual fan and battery module, preserve power and data requirements, and document the alarm state. Do not remove the controller or memory media until the project and retained-data recovery plan is confirmed.
Q6
Which engineering details should accompany an RFQ for 6AU1425-2AD00-0AA0?
Include the full order number, controller firmware, SIMOTION engineering version, axis count, CompactFlash identification, DRIVE-CLiQ topology and PROFIBUS/PROFINET roles. This lets the service spare be reviewed against the installed machine rather than only by family name.

Other Products

XF830A SDI-OE-S NA200T IZMX-RP16A-200
LFI520 4100LR12 SC200-00
SCD2200-RTU PS-22 IC200MDD844F IC200MDL650L
ABB 1SDH001000R0505-B0821 BS6151 01 SP01 ZBRN2
FGR-002 AMAX-2241 8530D-I
THS710 105S-1 SC42-EP08
AMAX-2241/PMA ADAP-KOOL eWONx005CD
CH-LMD1 SP-0108-H2 ABB 2CDG110137R0011
IMD-IM20 / IM20DEMO Abb 3BSE038226R1 SWH-4200
ABE7 P16T334 81672-01 LP/ 557-180-203

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000