siemens 6av6643 0ba01 1ax0 simatic op 277 6 inch panel-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6AV6643-0BA01-1AX0 SIMATIC OP 277 6-inch Panel

Product Name: SIMATIC OP 277 6-inch Operator Panel
Brand Name: Siemens
Model Number: 6AV6643-0BA01-1AX0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Contact info
  • Description
  • Panel Integration
  • Specifications
  • Project Transfer
  • Commercial Term
  • FAQ
  • Other Products
  • Recommended Products
Legacy 5.7-inch SIMATIC HMI operator panel with membrane keys, Ethernet and serial communication
The OP 277 combines a 5.7-inch 320 x 240 TFT display with 24 function keys, 4 MB configuration memory, Ethernet, USB host and RS422/485 interfaces. Exact project, panel cutout, power, communication and lifecycle checks are essential before installation or replacement.
Project and lifecycle check: Confirm the complete order number, WinCC flexible project, communication driver, 24 V DC supply, panel cutout, key assignment and backup method. Siemens lists a P.M490 target date of 1 October 2026, so preserve the project and plan the spare strategy without assuming a drop-in successor.

Contact info

Description

6AV6643-0BA01-1AX0 is the Siemens SIMATIC OP 277 6-inch key-operated panel. Its 24 function keys, including 18 with LEDs, support machine operation where tactile input and local status indication are required.
Before changing 6AV6643-0BA01-1AX0, create a verified project and recipe backup and record the configured PLC connection, IP settings, serial interface parameters, transfer mode and key functions. Restore communication and basic navigation before reconnecting process commands.

Panel Integration

Mechanical fit, electrical supply and project identity should be verified together before the old HMI is removed.
Project archive
Save the editable WinCC flexible project, recipes, passwords, communication settings and transfer method.
Cabinet fit
Check the existing cutout, mounting clamps, rear clearance, cable bend radius and access to USB and communication ports.
Interface match
Record whether the PLC link uses Ethernet or RS422/485 and preserve every address, rate and termination setting.

Specifications

Product type designation SIMATIC OP 277 6-inch
Order number 6AV6643-0BA01-1AX0
Display 5.7-inch TFT, 320 x 240 pixels, 256 colors
Operator input Membrane keyboard with 24 function keys; 18 keys with LED
Configuration memory 4 MB
Communication Ethernet 10/100 Mbit/s and RS422/485
USB interface USB host 1.1
Supply voltage 24 V DC; permitted range 20.4 to 28.8 V
Engineering reference WinCC flexible 2005 Standard SP1 or later
Device dimensions Approximately 308 x 204 x 63 mm
Device weight Approximately 1.19 kg
Lifecycle reference P.M490 target date: 1 October 2026

Project Transfer

A controlled restore separates panel hardware, transfer connection and PLC communication faults during commissioning.
Initial power-up
Verify the 24 V DC supply and polarity, then confirm the panel starts normally before downloading the project.
Transfer check
Use the documented transfer channel and matching engineering software; do not overwrite the only known-good project.
Functional test
Check navigation, key LEDs, alarms, recipes, trends and PLC writes in a safe machine state before release.

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

FAQ

Q1
Can the existing WinCC flexible project be transferred to 6AV6643-0BA01-1AX0?
Confirm that the project targets OP 277 6-inch and that the engineering installation supports the required WinCC flexible version. Keep the editable source, archive and transfer settings; a runtime backup alone may not support later editing.
Q2
What compatibility details should be checked before installing 6AV6643-0BA01-1AX0?
Match the complete order number, PLC driver, Ethernet or RS422/485 connection, project resolution, key assignments, 24 V supply and panel cutout. Record any external USB device and serial termination before removal.
Q3
How should 6AV6643-0BA01-1AX0 be prepared for cabinet installation?
Verify the cutout and rear clearance, inspect the gasket and mounting hardware, provide a stable 20.4 to 28.8 V DC supply and route communication cables separately from power conductors according to the cabinet design.
Q4
Why can 6AV6643-0BA01-1AX0 power up but show no PLC data?
Check the selected PLC driver, IP or serial parameters, cable and termination, PLC operating state and the downloaded connection object. Diagnose one interface at a time before changing the project or replacing hardware.
Q5
What should be backed up before replacing 6AV6643-0BA01-1AX0?
Preserve the editable project, transfer password and channel, recipes, archives, user administration, IP and serial settings, PLC connection and photographs of the key labels. Test that the backup can be opened before the outage.
Q6
How does the lifecycle status of 6AV6643-0BA01-1AX0 affect spare planning?
Siemens lists a P.M490 target date of 1 October 2026. Verify the current status at purchase time, retain a serviceable exact spare and plan an engineered HMI migration that includes project conversion, panel mechanics and communication testing.

Other Products

U891RX
PN:TPNN0077
TIS-DMX-48
6ES7658-1GX08-2YT7
FS-B3510
CS60 39159-02
60-692-21
CS540 84693-03
TE500CW12D2A1E2
LV429571 4P4D NSX100B TM80D
BT-0D-HL-1
813S-V3-400V
DR4208SGM
D5014S
CPO-MMI-WL
MCR-SL-DU/1
MSR142RTP 440R-G23215
127610-01
VT5400
60HH-S
GAMAX2
DLAF8000
VROM-101
ADV151-E10
12.1600 605 0056 R0002
IZM-KLP-SO-RONIS
MTN649202
HDA032Z
BMXAMI0410H
REF.04813