No. Parallel switching for uprating is not permitted; redundant load control is a separate supported use.
SIMATIC ET 200SP HA DQ16 Digital Output Module
Brand Name: Siemens
Model Number:
6DL1132-6BH00-0PH1
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
| Model Number | 6DL1132-6BH00-0PH1 |
| Module designation | DQ 16x24VDC/0.5A HA |
| Digital outputs | 16 |
| Output type | Current-sourcing |
| Nominal supply voltage | 24 V DC |
| Permissible supply range | 19.2 to 28.8 V DC |
| Rated no-load current | 60 mA |
| Maximum no-load current | 70 mA |
| Rated output voltage | 24 V DC |
| Maximum output current per channel | 0.5 A |
| Maximum output current per module | 8 A, subject to temperature derating |
| Maximum lamp load | 5 W |
| Load resistance range | 48 Ω to 12 kΩ |
| Typical short-circuit threshold | 0.7 to 1.3 A; IO redundancy up to 2.6 A |
| Wire-break test current | 0.7 mA; doubled with IO redundancy |
| Inductive shutdown-voltage limit | L+ minus 37 to 41 V |
| Typical output ON delay | 50 µs |
| Typical output OFF delay | 100 µs |
| Maximum resistive switching frequency | 100 Hz |
| Maximum inductive switching frequency | 2 Hz |
| Maximum lamp switching frequency | 10 Hz |
| Maximum shielded cable length | 1000 m |
| Maximum unshielded cable length | 600 m |
| Output address space | 2 bytes + 2 bytes QI information |
| Isolation test | 1500 V DC / 1 minute, type test |
| Operating temperature, horizontal | -40 to +70 °C |
| Operating temperature, vertical | -40 to +60 °C |
| Channel-to-channel isolation | No |
| Channel-to-backplane isolation | Yes |
| Redundancy capability | With terminal block M1 |
| Color code | CC02 |
| Engineering, STEP 7 | V5.6 or later |
| Engineering, TIA Portal | V16 or later |
| Engineering, PCS 7 | V9.0 or later |
| PROFINET device description | GSDML V2.3 |
| Sales | Phone/Whatsapp | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
Siemens 6DL1132-6BH00-0PH1 is the SIMATIC ET 200SP HA digital output module DQ 16x24VDC/0.5A HA. It provides sixteen current-sourcing output channels. Channel diagnostics support identification of field-circuit faults. The module uses a nominal 24 V DC supply. Redundant operation is available with the specified terminal-block arrangement.
The 6DL1132-6BH00-0PH1 switches suitable field loads in a compatible process-automation station. Wire-break and short-circuit diagnostics help localize channel problems. The terminal-block type and redundancy configuration must agree with the station design. Cable routing and temperature-related current derating must be included in the installation plan. This Siemens ET 200SP HA output module supports the configured process I/O architecture.
Switch suitable field loads from the configured ET 200SP HA process I/O station.
Use the supported per-channel diagnostics to distinguish wire-break and short-circuit conditions.
Implement the permitted redundant control of a load with the matching terminal block and station configuration.
No. Parallel switching for uprating is not permitted; redundant load control is a separate supported use.
The supported redundancy arrangement requires the specified M1 terminal-block configuration.
Yes. Wire break and short circuits to ground or L+ can be diagnosed channel by channel.
No. The allowable total current depends on mounting orientation and ambient-temperature derating.
Yes. Substitute values are supported within the configured station behavior.
Account for the diagnostic test current and the doubled test current in an IO-redundant arrangement.
Company was founded in Xiamen, Fujian, China, in 2005 with a team of only four people. At that time, we mainly served selected European and North American markets, supplying commonly requested industrial automation products from Siemens, Allen-Bradley and Bently Nevada. Although the business was still developing and we completed relatively few orders, this period helped us build essential product knowledge and international trade experience.
By 2017, our team had grown to approximately 30 people, and we had established a warehouse for in-stock automation components. Our business expanded across Europe, North America and Southeast Asia, while our product range grew from popular models to scarce and discontinued industrial automation parts. As our product knowledge and service experience increased, we completed nearly 20 orders per month on average.
Today, Company serves customers worldwide with a professional team of approximately 60 people. Our warehouse holds a broad selection of industrial automation components, including popular products, hard-to-find parts and discontinued models. We now complete more than 30 orders per month, with an average monthly transaction value of approximately USD 3 million. We have established long-term partnerships with nearly 30 customers from different countries and welcomed almost 40 international customers to visit our company.
Since our company was founded, we have served every customer with sincerity and professionalism. Our prices may not always be the lowest, but we earn long-term trust through quality products, dependable after-sales support, honest condition reporting, timely communication and responsible delivery. Our goal is to build lasting partnerships rather than pursue one-off transactions.
| LT-840-350 | SPAC-H450-W-US | MPH-AC003B |
| RRPAE00 | QLCC01 | HHU32100 |
| C2ENET-1 | CAM301 | R0f1314228/5 |
| PPM4-PN-MAINS-24 | F430R3V10 | SMC5500/S |
| MX-9.14104.1.1.0 | PCO3000AM0 | MX-SM-N76 |
| PR24D06-2CO-M-B5/P | DE-304 | DE4161-001 |
| HDP5000 | INT-1534-M-5-M-111 | INF-1001 |
| EC17Z | B72G-2AK-QD1-NCG | MP2HI3HCGL |
| DAD4-CBL-OBD-01 | CT6500 | SRD-91 |
| SMT-CD-R20 | M150/10-14-10 | SIM-CNR04E |
| ULFIM-D37M-45-XOR | MA1480B | BT-0D-HL-1 |
| L4004N | SD55X | CT-0155NSP-SB2L-E |
| PR160 | LD-C4ZB-H2-21 | K9142TP |