siemens 6dp1360 8ba teleperm xp fum360 fail safe binary output module-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6DP1360-8BA TELEPERM XP FUM360 Output Module

Product Name: TELEPERM XP FUM360 Fail-Safe Binary Output Module
Brand Name: Siemens
Model Number: 6DP1360-8BA
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
  • Overview
  • Description
  • Safety Integration
  • Specifications
  • Service Diagnostics
  • Contact info
  • Commercial Term
  • FAQ
  • Other Products
  • Recommended Products
Legacy TELEPERM XP FUM360 fail-safe binary output module for safety-related actuator control
FUM360 is used in TELEPERM XP / AS 620 F safety applications to command actuators such as solenoid valves. Its exact rack position, output assignment, field wiring, redundancy concept and safety validation records are essential for a controlled replacement.
Project-led reviewMatch the full 6DP1360-8BA label and revision, rack and slot, APF configuration, 24 V field circuits, output loads and proof-test records. No substitution should be accepted without application-specific safety verification.

Description

6DP1360-8BA is a Siemens TELEPERM XP FUM360 module used for fail-safe binary output functions. The front indicators and channel test features support service work, but the final safe state depends on the complete actuator and safety architecture.
Before exchange, save the first diagnostic evidence and document each channel, field terminal, supply and redundancy partner. Replacement and restart must follow the plant safety procedure, including proof testing of every affected output and final element.

Safety Integration

The module must be evaluated as part of the complete fail-safe signal path, not as an isolated board.
Channel map
Record every output, load, fuse, terminal and expected safe state before disconnection.
Redundancy role
Document the partner channel or module and how the plant logic detects a single failure.
Proof test
Prepare an approved test for each final element and verify the safe reaction before release.

Specifications

Product type designation
TELEPERM XP FUM360
Order number
6DP1360-8BA
Module role
Fail-safe binary output module
Typical application
Safety-related actuator and solenoid-valve control
System family
TELEPERM XP / AS 620 F
Field supply reference
24 V DC
Service requirement
Exact revision, rack and channel assignment must be verified
Lifecycle note
Legacy safety-system spare; application-specific proof testing required

Service Diagnostics

Preserve fault evidence and isolate field-circuit causes before changing a legacy safety module.
First evidence
Photograph channel LEDs and record the plant state, event time and diagnostic message before reset.
Field circuit
Check the 24 V supply, fuses, load current, wiring and final element under the plant procedure.
Controlled exchange
Use ESD controls, label connectors and compare every setting and revision before insertion.

Contact info

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

FAQ

Q1
How can I confirm that 6DP1360-8BA is the correct FUM360 spare?
Match the full order number, hardware revision, rack and slot, connector arrangement and APF project record. Also compare the channel map, 24 V field circuits, redundancy partner and documented safe state.
Q2
What compatibility information is needed before installing 6DP1360-8BA?
Provide the TELEPERM XP station and AS 620 F context, rack position, module revision, output loads, field supply, wiring diagrams and proof-test procedure. A visually similar FUM module is not sufficient evidence of compatibility.
Q3
How should 6DP1360-8BA be replaced in a safety-related system?
Use the approved lockout and safety bypass procedure, place the process in a defined safe condition, label every connector and apply ESD controls. After installation, perform the complete channel and final-element proof test before release.
Q4
What should be checked when 6DP1360-8BA indicates an output fault?
Preserve the first LED and system diagnostic evidence, then check field supply, fuse, wiring, load current, short circuit and the final actuator. Compare the redundant channel and avoid resetting the only useful fault evidence too early.
Q5
Can 6DP1360-8BA be substituted by another FUM module?
Do not substitute by family name alone. Safety function, output architecture, revision, connector and APF configuration must match, and any alternate requires documented engineering assessment and validation for the complete safety loop.
Q6
What records should be retained after servicing 6DP1360-8BA?
Keep before-and-after module labels, rack and channel records, fault evidence, wiring checks, calibration or test equipment records, proof-test results, restored configuration and the final authorization to return the loop to service.

Other Products

ABB GHQ 605 0056 R0002 DDM-163 XD508
DIN-4DIMFLV4 6501749 3300 XL 5/8MM 330180-12-05 ADAM-5000
KJ2003X1-BA2 12P2093X112 GS-CO-S AIO16R-L
EC30 50100-00 LON-LON HIT-DE 150 ww RX7s-24
GHQ6050059R0006 BP3-1V11B5C111 C1B
XY2CE2A296 220614 R0F1314228/5 TVM113-013
X13760335-01 Rev.R TD7 EXP-1048 METSEPM5560
HWS600-24/LNT 181737 RL28-55-LAS-2840/47/115b DDI 24-12 018
SNB-5003P 3122A 5000V ABB MU6301/90-811-500 2CKA006300A1405
15B10730G1 EDP70 IR-720-EUR A51 6762250 AE4 6762264 AE02

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000