| SALES | PHONE / WHATSAPP | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model Number | 6ES7158-3AD00-0XA0 |
| Product Family | SIMATIC PN/PN Coupler |
| Product Type | PROFINET network coupler |
| Ethernet Service Rate | 10 Mbit/s |
| PROFINET IO Rate | 100 Mbit/s full duplex |
| Transmission Method | 100BASE-TX |
| Auto Negotiation | Yes |
| Auto Crossing | Yes |
| Internal Switch | Yes |
| Bus Protocol | PROFINET IO TCP/IP |
| Ethernet Services | Ping, ARP, SNMP / MIB-2 |
| PROFINET Interfaces | 4 x RJ45 |
| Vendor ID | 002A hex |
| Device ID | 0604 hex |
| Rated Supply | 24 V DC |
| Supply Range | 20.4 to 28.8 V DC |
| Reverse Polarity Protection | Yes |
| Power Failure Bypass | 5 ms minimum |
| Isolation Test | 500 V DC |
| Supply Current | 400 mA approximate |
| Power Loss | 6 W approximate |
| Dimensions | 120 x 132 x 75 mm |
| Weight | 282 g |
| PURCHASING TERM | DETAILS |
|---|---|
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
|
01
Receive data on network side 1The first PROFINET system writes configured I/O data.
|
02
Map the coupling areaThe module transfers data through the configured exchange map.
|
|
03
Present data on network side 2The second PROFINET system reads the mapped information.
|
04
Keep networks separatedElectrical isolation and independent configurations preserve network boundaries.
|
|
4
RJ45 ports
|
100 Mbit/s
PROFINET full duplex |
500 V DC
Isolation test |
| Controller-to-controller exchangeTwo separate PROFINET IO systems share cyclic data. | Integrated four-port switchingEach side has practical network connection options. | Standard Ethernet diagnosticsPing, ARP and SNMP / MIB-2 aid commissioning. |
| 01 | What problem does 6ES7158-3AD00-0XA0 solve between PROFINET systems? | It exchanges configured I/O data while the two networks remain separate. |
| 02 | How many RJ45 ports are available on 6ES7158-3AD00-0XA0? | The exact module provides four PROFINET RJ45 interfaces. |
| 03 | Which transmission method is used by 6ES7158-3AD00-0XA0? | It uses 100BASE-TX at 100 Mbit/s full duplex for PROFINET IO. |
| 04 | Why must both engineering projects be checked for 6ES7158-3AD00-0XA0? | Each network has its own device configuration and the exchanged data areas must agree. |
| 05 | What supply tolerance applies to 6ES7158-3AD00-0XA0? | Use 20.4 to 28.8 V DC around the 24 V nominal supply. |
| 06 | Which identity values identify 6ES7158-3AD00-0XA0? | The manual lists vendor ID 002A hex and device ID 0604 hex. |
| LIN52V | AM-200 | PR24D06-2CO-M-B5/P |
| cPCI-R3610T | PS-2121 | DVI-2325-FO |
| BMTI5 | LR9502 | IS-DG102P-F-1 |
| PX-Q120 | PPM4-PN-MAINS-24 | NTM1A10C |
| HDL-M/R8.16.1-232 | LP7-18-30A | VCL-E1-030 |
| SQ121B6220 | DDLEDC605GL | ETH-02 |
| CLIOP821A | MCI-211G | IS320WH |
| FTS35-4011-22M | aci1230 | PCO3000AM0 |
| TMT112-AAAAA | ADC8220/22 | sca-213 |
| RH390 | HDP5000 | ULFIM-D37M-45-XOR |
| SE7350F5045B | HWS600-48/LNT | EIR608-4SFP |
| E-E720MBA | EHS-220 | PG320240WRT-MNN-IQ |
| CVS-9911MN | K-6010 | DPG500 |