siemens 6es7288 2dr32 0aa0 sm dr32-0

SIMATIC S7 Series

Home >  Products >  SIEMENS >  SIMATIC S7 Series

Siemens SIMATIC S7-200 SMART 6ES7288-2DR32-0AA0 Digital I/O SM DR32, 16DI/16DO, 16 DI 24 V DC, Sink/Source, 16 DO, relay 2 A

SIEMENS · SIMATIC S7-200 SMART
6ES7288-2DR32-0AA0
SIMATIC S7-200 SMART, Digital I/O SM DR32, 16DI/16DO, 16 DI 24 V DC, Sink/Source, 16 DO, relay 2 A
I/O
16 DI / 16 DO
Output
Relay, dry contact
Rating
2 A per output
Selection gate: Confirm contact voltage, load type, inrush, switching frequency, common grouping and external protection.
  • Overview
  • Applications
  • Data
  • Construction
  • Environment
  • Selection
  • Verification
  • Commercial
  • Models
  • Recommended Products
OFFICIAL PRODUCT IDENTITY
Product Overview
ARTICLE NUMBER
6ES7288-2DR32-0AA0
PRODUCT TYPE
SM DR32, DI 16x24 V DC, DQ 16x relay/2 A

This Siemens SIMATIC S7-200 SMART module is identified by article number 6ES7288-2DR32-0AA0. Its official description is: SIMATIC S7-200 SMART, Digital I/O SM DR32, 16DI/16DO, 16 DI 24 V DC, Sink/Source, 16 DO, relay 2 A.

Core selling point: Sixteen 24 V DC inputs and sixteen 2 A relay outputs in one digital I/O module.

Commercial scope
Stock, condition, testing, warranty, dispatch and price are not established by technical documentation. Confirm these items before quotation.

Applications

SM DR32
Application-focused I/O expansion
  • Combines sixteen 24 V DC digital inputs with sixteen relay outputs for mixed I/O expansion.
  • Accepts sink/source input wiring as documented by Siemens.
  • Provides relay dry contacts for loads within the official voltage, current and switching limits.
  • Separates input and output functions while retaining channel-status indication.
Application check
Confirm contact voltage, load type, inrush, switching frequency, common grouping and external protection.

Data

Rated supply voltage
24 V DC; permissible range 20.4 V DC to 28.8 V DC.
Current consumption
Typical 165 mA from 24 V DC input power and typical 165 mA from the 5 V DC backplane bus.
Digital inputs
16 inputs in 2 groups; 24 V DC sink/source; IEC 61131 Type 1.
Input signal range
Signal 0 below 5 V DC; signal 1 from +15 V DC to +30 V DC.
Input current and delay
Signal 1 typically 4 mA; maximum input delay 200 µs in each direction.
Relay outputs
16 relay, dry-contact outputs; rated current 2 A per output.
Contact load
Maximum 2 A for resistive or inductive load; lamp load 30 W DC or 200 W AC.
Output delay
Maximum 10 ms from 0 to 1 and 10 ms from 1 to 0 for resistive load.
Cable length
Inputs: 500 m shielded / 300 m unshielded. Outputs: 500 m shielded / 150 m unshielded.
Dimensions and weight
70 mm × 100 mm × 81 mm; approximately 295.4 g.
Rating note
Temperature, mounting position, channel grouping and load behavior can affect permissible operation. Check the current Siemens document revision before final engineering.

Construction

CONSTRUCTION
SM DR32
  • Digital inputs are optocoupler-isolated; relay outputs use dry contacts.
  • Input-status and output-status LEDs are provided.
  • Official isolation test values are 500 V AC for inputs and 1500 V AC for outputs, each for 1 minute.
  • Use the exact Siemens terminal assignment and common grouping for the hardware revision.
Wiring control
Use the exact Siemens terminal diagram for the applicable article and hardware revision before energizing.

Environment

ENCLOSURE
IP20
SHORT-CIRCUIT PROTECTION
Not provided
DOCUMENTATION
Verify revision
  • IP20 degree of protection.
  • Short-circuit protection is not integrated; external circuit protection is required as determined by the application.
  • CE, EU/UK declarations, China RoHS and EAC information are listed in Siemens product data.

Selection

1 · System
Confirm the exact S7-200 SMART CPU, expansion position, module capacity and manual revision.
2 · Electrical
Confirm contact voltage, load type, inrush, switching frequency, common grouping and external protection.
3 · Protection
Define application-appropriate overcurrent, short-circuit and isolation measures.
4 · Wiring
Follow the official terminal assignment and verify conductors, commons, polarity and cable length.
Selection gate
Confirm the complete article number 6ES7288-2DR32-0AA0 and the final I/O schedule before quotation.

Verification

Article identity
Match 6ES7288-2DR32-0AA0 on the quotation, label and available documentation.
System fit
Confirm S7-200 SMART CPU compatibility, permitted expansion position and module capacity.
Channel topology
I/O: 16 DI / 16 DO; Output: Relay, dry contact; Rating: 2 A per output.
Load schedule
Confirm contact voltage, load type, inrush, switching frequency, common grouping and external protection.
Protection
Define external protection because integrated short-circuit protection is not specified.
Documentation
Request the applicable datasheet, declarations and system-manual revision when required.
Commercial evidence
Confirm condition, stock, current photos, testing, warranty, dispatch and payment terms before order.

Commercial

Physical stock
Confirm before quotation. No quantity claim is made without current warehouse evidence.
Condition
New, used or refurbished status is subject to verification for the offered unit.
Current photos
Current physical-product and nameplate photos are available on request, subject to availability.
Warranty
Confirm the warranty period and coverage before quotation.
Dispatch time
Subject to verification after stock, inspection and destination are confirmed.
Testing
Testing status and any available test record are available on request; do not assume a test has been completed.
Payment methods
Accepted methods will be stated in the pro forma invoice; confirm before quotation.
Quotation response
Subject to verification based on quantity, destination and documentation scope.
Transaction confidence
Company documents, payee details and the transaction process are available on request. Verify beneficiary and order details before payment.
No absolute commercial promise
Technical documentation does not establish live inventory, sale condition, warranty, dispatch date or test status.

Models

Cross-reference selection: The following model references are provided for enquiry planning. Confirm the complete part number, manufacturer, revision and application before quotation.
RMK-16R-DV-B
5714A
ND20LITE-22100M1
KHA6-SH-Ex1
10270-224-01
HMT335
700-K40E-ZY
LA305-S/SP1
05-001-02
DMC-4KZ-HD
QD3900H1
10216100
FS-IOB-0001R
HD-RX-201-CE
IC-M304
HWS600-24
1350/D2F3D1B5C000
HP24100WPCE
lnl-xf2110dgf17
CS1W-ID261
YPP6000-6R0
2CDG110091R0011
CMD5B4000
MU325A
IME3015BBPkg
PCS45
Ex-AR
E84MAPACT
1-24DC/600AC-30
14080101
DO-523-A2
1771-OAD
37104491000
WV-V1330LK
D1061S
SXWSC3XSELXX
REG-K/8x230/16
PRO32R2
Multi9
ETHI1F4p1C
AS1200HAT-SPL
FT3700-20
APIN0305
AX-LDPT482V-1
WVR5000
500-033370
Mri-M500S
077671L
DGBP-E2CRS
ETOR-4
Selection note: Availability, condition, testing, warranty and dispatch are subject to verification. Request the current quotation and supporting product evidence before ordering.
Request a verified quotation
Email InquiryWhatsApp
Email: [email protected]
WhatsApp: +86 18159889985

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000