Model Number
|
6GK1503-3CA01
|
|
PROFIBUS transmission rate
|
9.6 kbit/s–12 Mbit/s
|
|
Electrical network channels
|
1 RS-485
|
|
Electrical network connector
|
9-pin Sub-D socket
|
|
Optical channels / sockets
|
2 / 4 BFOC sockets
|
|
Measuring output connector
|
2-pole terminal block
|
|
Supply and signaling connector
|
5-pole terminal block
|
|
Rated supply voltage
|
24 V DC
|
|
Supply voltage range
|
18–32 V DC
|
|
Current consumption, maximum
|
0.2 A at 24 V DC
|
|
Signal propagation delay
|
≤6.5 bit times
|
|
Optical wavelength
|
660 nm
|
|
PCF fiber core / cladding
|
200/230 µm
|
|
POF fiber core / cladding
|
980/1000 µm
|
|
PCF launch power, increased setting
|
-17 dBm
|
|
POF launch power, factory setting
|
-9.5 dBm
|
|
POF launch power, increased setting
|
-5 dBm
|
|
Optical receiver sensitivity
|
-23 dBm
|
|
Receiver overdrive limit, typical
|
-7 dBm
|
|
PCF link length, maximum
|
400 m at 10 dB/km; increased transmit power
|
|
POF link length, maximum
|
80 m at 230 dB/km
|
|
RS-485 bus termination supply
|
5 V DC, +5% / -10%, pin 6
|
|
RS-485 input dielectric strength
|
-7 to +12 V
|
|
Bit error rate
|
<10⁻⁹
|
|
Permitted input signal distortion
|
±30%
|
|
Permitted input bit-length deviation
|
±0.12%
|
|
Output average bit-length deviation
|
±0.01%
|
|
Operating temperature
|
0–60 °C
|
|
Storage / transport temperature
|
-40 to +70 °C
|
|
Relative humidity, maximum
|
95% at 25 °C, non-condensing
|
|
Ingress protection
|
IP40
|
|
ESD immunity
|
±6 kV contact discharge, EN 61000-4-2
|
|
Burst immunity
|
±2 kV on supply, signaling contact and RS-485
|
|
MTBF at 40 °C
|
108.02 years
|
|
MTBF at 60 °C
|
51.32 years
|
|
Sales
Jim Pei
|
Email
|
Phone/Whatsapp
|
Siemens 6GK1503-3CA01 is the SIMATIC NET PROFIBUS OLM/P12 V4.1 optical link module. It links an electrical PROFIBUS segment to plastic fiber-optic transmission paths. The configuration provides an RS-485 interface and two optical channels with BFOC connections. Automatic transmission-rate detection supports the configured PROFIBUS network. The measuring output and local indicators assist assessment of optical reception.
The 6GK1503-3CA01 supports optical line, star and redundant ring network arrangements when configured as described for the OLM system. Fiber-optic links provide electrical isolation between connected network sections. Link monitoring helps identify interruptions in the optical path. The signaling contact can report a detected fault to the surrounding installation. Select the correct fiber type, transmit-power setting and PROFIBUS timing before commissioning or replacement.
|
Nov-54DAC-633EDM4T 4940275
IR425 / ir425-D4-2S5550/4,NG100,0CE20-I
AR-133400-NCMP2B.88453564086631-2 HL-20
SK-140TRHR0F1314228/5 TVM113-013TSC2
IS23DI0XCD000QSNE-4S10-D0AC808.9-1
DMC-C 6504086S-3-TCPUSE-H-Di6CRC3044BC
AUH-01EV45EM4-111-DR2
ULX1-R4ZN1CL-kLIC-DIPCO3000ES0
Mini8SB522ACLAXEH00ND100A
PS00B01KNXDVI-M PN:26-584-015363 EV45
AT-MC102XL-40 990-000445-40AKM115SF132UNC-500
009SMASISTP1013-141-LRTPR160
OPT-B8-V:3Pt100 181B0305 OPT-B8-VAV5155DNATW-RC13
|