Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens 6sl3225 0be27 5aa1 sinamics g120 pm250 power module-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6SL3225-0BE27-5AA1 SINAMICS G120 PM250 Power Module

Product Name: SINAMICS G120 PM250 Power Module
Brand Name: Siemens
Model Number: 6SL3225-0BE27-5AA1
Place of Origin: United Kingdom
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Description
  • Specifications
  • Drive Commissioning
  • Contact info
  • Commercial Term
  • About Company
  • FAQ
  • Other Products
  • Recommended Products
Regenerative PM250 Power Stage for SINAMICS G120 Drives

Siemens 6SL3225-0BE27-5AA1 is a SINAMICS G120 PM250 regenerative power module for 380 to 480 V three-phase supplies.

Selection checkpoint: Confirm the PM250 article number, motor duty, overload class, control-unit compatibility, line conditions and saved drive parameters before replacement.

Description

6SL3225-0BE27-5AA1 is a frame-size FSC PM250 power module with an integrated class A filter and energy-recovery capability. Siemens rates it for 11 kW low-overload duty or 7.5 kW high-overload duty under the documented temperature and duty conditions.

The power module is supplied without a Control Unit or BOP. A replacement plan must therefore retain the installed Control Unit, motor data, drive parameters and wiring record, while all electrical work follows the machine isolation and commissioning procedure.

Specifications

Technical parameter Value
Product type designation SINAMICS G120 PM250
Article number 6SL3225-0BE27-5AA1
Supply 380 to 480 V 3 AC, 47 to 63 Hz
Low-overload power 11 kW
High-overload power 7.5 kW
Line filter Integrated class A filter
Energy behavior Regenerative
Frame size FSC
Degree of protection IP20
Scope note Without Control Unit and BOP
Manufacturer Siemens

Drive Commissioning

01
Regenerative operation
Return braking energy through the documented PM250 drive arrangement.
02
Filtered power stage
Use the integrated class A line filter within the approved installation.
03
Duty selection
Match high- or low-overload motor duty before approving the module.
04
Parameter continuity
Preserve Control Unit settings and motor commissioning data during exchange.

Contact info

Commercial Term

Quotation Payment Lead time Shipping Warranty
Contact us for current price and availability T/T or agreed terms Confirmed with the quotation DHL, FedEx, UPS or agreed freight 12 months

About Company

SupplyPLCs supports exact-model review, product-condition confirmation and responsive industrial automation sourcing.
Share the complete order number, installed-system context and destination. Our team will coordinate availability, shipment options and available official product documentation.

FAQ

Q1
How can I verify that 6SL3225-0BE27-5AA1 is correctly sized for the motor and machine duty?
Compare the motor current and duty cycle with the documented low-overload and high-overload ratings, not only the motor nameplate power. Confirm the supply voltage, ambient conditions and required braking behavior before approving the module.
Q2
Which Control Unit checks are required before replacing a PM250 with 6SL3225-0BE27-5AA1?
Record the installed SINAMICS Control Unit type, firmware and parameter backup, then confirm that the approved hardware combination covers this PM250. The power module is supplied without a Control Unit, so the control hardware and commissioning data remain separate decisions.
Q3
Why might the drive report power-stage or line faults after 6SL3225-0BE27-5AA1 is installed?
Keep the drive safely isolated while checking the three-phase supply, protective earth, line connections and motor wiring against the original documentation. Read the exact SINAMICS alarm before changing parameters or replacing additional components.
Q4
How should I preserve the drive setup before exchanging 6SL3225-0BE27-5AA1?
Create a verified parameter backup from the installed Control Unit and record motor data, application macros, communication settings and safety-related commissioning records. Restore the approved data only after the replacement hardware and wiring have been checked.
Q5
What should I examine if 6SL3225-0BE27-5AA1 trips during acceleration but runs at light load?
Compare the measured load and acceleration profile with the selected overload duty, inspect the motor and output wiring, and review current-limit and fault history. Do not raise protection limits until the mechanical load and motor data are confirmed.
Q6
Which details should I provide when requesting 6SL3225-0BE27-5AA1 for a service replacement?
Provide the exact order number, installed Control Unit, firmware, motor rating, supply voltage, duty cycle, cabinet temperature and fault history. This information helps distinguish the filtered regenerative PM250 variant from other G120 power modules.

Other Products

XF830A SDI-OE-S NA200T IZMX-RP16A-200
LFI520 4100LR12 SC200-00
SCD2200-RTU PS-22 IC200MDD844F IC200MDL650L
ABB 1SDH001000R0505-B0821 BS6151 01 SP01 ZBRN2
FGR-002 AMAX-2241 8530D-I
THS710 105S-1 SC42-EP08
AMAX-2241/PMA ADAP-KOOL eWONx005CD
CH-LMD1 SP-0108-H2 ABB 2CDG110137R0011
IMD-IM20 / IM20DEMO Abb 3BSE038226R1 SWH-4200
ABE7 P16T334 81672-01 LP/ 557-180-203

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000