SIEMENS | SIMATIC S7-1200
6GK7243-5DX30-0XE0
CM 1243-5 PROFIBUS DP Master
PROFIBUS DP-V1 master | 9-pin D-sub RS485 | 9.6 kbit/s to 12 Mbit/s
|
Siemens 6GK7243-5DX30-0XE0
The 6GK7243-5DX30-0XE0 is a SIMATIC S7-1200 CM 1243-5 communications module that operates as a PROFIBUS DP master. It supports cyclic DP communication, acyclic DP-V1 services, S7 communication and PG/OP communication through a 9-pin D-sub RS485 interface.
Core value: integrated PROFIBUS DP master connectivity for SIMATIC S7-1200 with cyclic, acyclic and engineering communication.
|
|
OFFICIAL SPECIFICATIONS | 6GK7243-5DX30-0XE0
|
|
|
Complete model
|
6GK7243-5DX30-0XE0
|
|
Product family
|
SIMATIC S7-1200
|
|
Product type
|
CM 1243-5 PROFIBUS DP master communications module
|
|
Dimensions
|
30 x 100 x 75 mm (W x H x D)
|
|
Weight
|
134 g net; 171 g packaged
|
|
Communication interface
|
PROFIBUS DP, RS485
|
|
Transmission standard
|
PROFIBUS DP-V1
|
|
Connector
|
9-pin D-sub female
|
|
Transmission rate
|
9.6 kbit/s to 12 Mbit/s
|
|
PROFIBUS address range
|
2 to 125 in operational use
|
|
Maximum DP slaves
|
32 per master with supported V3 or later CPU
|
|
Rated supply voltage
|
24 V DC external supply
|
|
Supply voltage range
|
19.2 to 28.8 V DC
|
|
Typical current consumption
|
100 mA
|
|
Power dissipation
|
2.4 W
|
|
Interface supply
|
15 mA at 5 V for bus termination
|
|
Electrical isolation
|
710 V DC for 1 minute
|
|
Installation position
|
Left of the SIMATIC S7-1200 CPU
|
|
Mounting
|
35 mm DIN rail
|
|
Conductor cross-section
|
0.14 to 1.5 mm2
|
|
Terminal tightening torque
|
0.45 N-m
|
|
Operating temperature
|
0 to +55 C with horizontal DIN rail; 0 to +45 C with vertical DIN rail
|
|
Storage and transport temperature
|
-40 to +70 C
|
|
Relative humidity
|
Up to 95%, non-condensing
|
|
Protection and functions
|
IP20; cyclic DP, acyclic DP-V1, PUT/GET S7 communication and PG/OP communication
|
|
CONTACT
STELLA
|
|
PROFIBUS master
Controls compatible PROFIBUS DP slaves from an S7-1200 automation station.
|
Cyclic data exchange
Transfers deterministic process input and output data through DP cyclic communication.
|
|
Acyclic services
Supports DP-V1 record and alarm services through the documented program instructions.
|
Engineering access
Provides S7 communication plus PG and OP communication over the PROFIBUS network.
|
|
External supply
|
24 V DC, 19.2 to 28.8 V range
|
|
Typical current
|
100 mA
|
|
Power dissipation
|
2.4 W
|
|
Interface
|
RS485 PROFIBUS DP-V1
|
|
Connector
|
9-pin D-sub female
|
|
Transmission rate
|
9.6 kbit/s to 12 Mbit/s
|
|
Termination supply
|
15 mA at 5 V
|
|
Electrical isolation
|
710 V DC for 1 minute
|
|
Terminal wiring
|
0.14 to 1.5 mm2 conductor; 0.45 N-m tightening torque
|
|
1 | Position the communications module
Mount the CM 1243-5 to the left of the SIMATIC S7-1200 CPU on a 35 mm DIN rail.
|
|
2 | Connect the external supply
Provide 24 V DC within 19.2 to 28.8 V and account for approximately 100 mA module current.
|
|
3 | Build the PROFIBUS segment
Use the 9-pin D-sub RS485 interface, approved PROFIBUS cable, correct shielding and termination, and a unique address from 2 to 125.
|
|
4 | Configure and commission
Configure the DP master and slave data in the engineering project, then verify cyclic data, acyclic services and diagnostics before operation.
|
|
Enclosure protection
IP20; mount inside a suitable electrical enclosure.
|
Temperature limits
0 to +55 C with horizontal DIN rail or 0 to +45 C with vertical DIN rail.
|
|
Isolation
PROFIBUS interface isolation verified by a 710 V DC, one-minute test.
|
Storage environment
-40 to +70 C and up to 95% relative humidity without condensation.
|
|
Install the module in an enclosure, use approved PROFIBUS wiring and termination, and follow the documented mounting-orientation temperature limit and S7-1200 CPU compatibility requirements.
|
|
|
Q1. How can a buyer verify the exact 6GK7243-5DX30-0XE0?
A. Match the complete Siemens MLFB on the module and packaging. The 5DX30 code identifies the CM 1243-5 PROFIBUS DP master, not a DP slave, Ethernet communications processor or another S7-1200 communications module.
|
|
Q2. How can New, Used and Refurbished condition be distinguished?
A. Request current photos of the front label, side MLFB and serial labels, 9-pin D-sub port, power terminals, DIN-rail latch and packaging. A new unit should show no connector wear, terminal marks, rail-latch damage, dust or replacement labels.
|
|
Q3. How should procurement verify the supplier?
A. Check the legal entity, registration, verifiable address, company-domain correspondence, bank-beneficiary consistency and traceability for 6GK7243-5DX30-0XE0 before payment.
|
|
Q4. Which technical points should an engineer confirm?
A. Confirm PROFIBUS DP-master function, DP-V1 requirement, 9-pin RS485 interface, 9.6 kbit/s to 12 Mbit/s rate, supported CPU version, 32-slave limit, 24 V DC supply, 30 x 100 x 75 mm size and 134 g net weight.
|
|
Q5. What physical evidence should be requested before payment?
A. Ask for dated photos or video showing the full MLFB, serial and hardware markings, D-sub pins, terminal condition, packaging labels and dimensions. If testing is offered, request a serial-numbered power-up and PROFIBUS diagnostic demonstration.
|
|
Q6. Can a similar 6GK7243 suffix replace this CM 1243-5?
A. Not automatically. Other communications modules may use a different protocol, master/slave role, connector, firmware requirement or program interface. Replacement requires confirmation of CPU compatibility, PROFIBUS role and engineering configuration.
|
|
60 INDUSTRIAL MODELS
|
||
|
VM0808
|
UNICON-P-1-4-3-06
|
CM 6010P
|
|
iMC2S-LV-D-1RJ45-1SFP
|
ANB10D-410
|
CRD3000-1001RR CRD-MC32-100INT-01
|
|
MHFP014BSSW
|
9602-0255
|
HP2+ ref 49364
|
|
LBB1946/00
|
DB-11 11E/885311C 575-294194-14
|
ID5055 IDC3050BBPKG
|
|
506001MED-8017X
|
MTN6725-0001/KNX
|
8200-1
|
|
SK-140TRH
|
PRS-1AIP1 F01U064686
|
TGP03
|
|
BD-B022
|
C75825A REV:5
|
PR630
|
|
DDRM104
|
EV100
|
DIUT2 S30810-Q2226-X100-9
|
|
UHF400
|
RB2 BA3
|
ABB PM583 / 1SAP140300R0271
|
|
A10135052 MMC-110A-F100
|
DD2002
|
CBS-4C-RA CBS-4
|
|
dL8
|
TA524 / 1SAP180600R0001
|
H117-174 8-200PSI
|
|
Urmet 1071/7
|
DMC202T
|
N10010
|
|
CSTR-SDB2R8AAAY400
|
CLLYUB4024S
|
WV-SC385E
|
|
ABB AI531 / 1SAP250600R0001
|
GT-VBC
|
QBM3020-5 S55720-S236
|
|
LV434011
|
ABB DI724F 3BDH000374R0001
|
ABB RD3P-48 IEC60947-2/M
|
|
IE-3000-8TC
|
010-0901-000 LP-1200
|
46779C-4 PR50
|
|
RO 8-1.4 C29F
|
149992-01
|
F4111A
|
|
1771-IC
|
3AXD5000003277
|
6200900
|
|
Q4D-LUBCE011-00
|
IQPanel2 QS9210-0G09-784
|
5502DAL
|
|
C-Bus2 L5508DSIP
|
LC-204
|
XEV22D-1P2CO
|