Complete model
|
6ES7522-5HH00-0AB0
|
|
Product family
|
SIMATIC S7-1500 / ET 200MP SM 522
|
|
Product type
|
DQ 16x230 V AC/2 A ST relay output module
|
|
Hardware status
|
FS02 or later
|
|
Firmware version
|
V1.1.0
|
|
Supply voltage
|
24 V DC; permissible range 20.4 to 28.8 V
|
|
Current consumption
|
185 mA maximum
|
|
Backplane bus power
|
0.8 W
|
|
Power loss
|
5 W typical
|
|
Digital outputs
|
16 relay outputs in groups of 2
|
|
Output voltage range
|
24 to 120 V DC or 24 to 230 V AC
|
|
Output current
|
2 A per channel maximum
|
|
Group current
|
4 A per group maximum
|
|
Module current
|
32 A maximum; observe manual limits
|
|
Switching frequency
|
1 Hz resistive or lamp load; 0.5 Hz inductive load
|
|
Cable length
|
1,000 m shielded; 600 m unshielded
|
|
Diagnostics
|
Supply-voltage monitoring and diagnostic alarm
|
|
Safety-oriented shutdown
|
Supports load-group shutdown up to SIL 1 and Category 2 / PL c
|
|
Protection / isolation
|
Channels isolated from backplane bus and load voltage
|
|
Operating temperature
|
-25 to 60 deg C horizontal; -25 to 40 deg C vertical
|
|
Dimensions
|
35 x 147 x 129 mm (W x H x D)
|
|
Weight
|
Approximately 350 g
|
|
Front connector
|
Not included; screw or push-in connector ordered separately
|
|
Engineering
|
TIA Portal V13 SP1 or later
|
|
Relay outputs
Sixteen relay channels are arranged in electrically separated groups of two.
|
Switching cycle counter
Each integrated relay supports an operating cycle counter from firmware V1.1.0.
|
|
Substitute value
Substitute output values can be configured for controller or communication faults.
|
Load-group shutdown
The module supports safety-oriented shutdown of load groups up to SIL 1 and Category 2 / PL c.
|
|
Coil supply
The relay coil supply uses 24 V DC within a 20.4 to 28.8 V range.
|
Output circuits
Contacts switch 24 to 120 V DC or 24 to 230 V AC loads.
|
|
Channel grouping
Sixteen outputs are arranged in groups of two; different phases are permitted.
|
Front connection
A screw-terminal or push-in front connector must be ordered separately.
|
|
Supply monitoring
The module monitors its 24 V DC supply and can issue a diagnostic alarm.
|
Status indication
RUN, ERROR, MAINT, PWR, channel status, and module diagnostic LEDs are provided.
|
|
Channel diagnostics
Wire-break and short-circuit diagnostics are not provided.
|
Isolation
Channel groups are isolated from the backplane bus and supply; type-test voltage is 3,100 V DC.
|
|
Module dimensions
35 x 147 x 129 mm; approximate weight 350 g.
|
Included part
A U-connector is included; the front connector is not included.
|
|
Mounting orientation
-25 to 60 deg C horizontally and -25 to 40 deg C vertically.
|
Load planning
Observe 2 A per channel, 4 A per group, cable ratings, and external B10 or B16 protection.
|
|
Q1. How can I verify that the quoted item is exactly 6ES7522-5HH00-0AB0?
Match the complete order number on the quotation, label, packaging, and invoice. Confirm DQ 16x230 V AC/2 A ST, relay outputs, FS02 or later, 16 channels, and the 35 mm module width.
|
|
Q2. How can I distinguish a new relay output module from a used or refurbished unit?
Request current photos of the Siemens label, housing, front-door area, terminal contacts, rail latch, and packaging. Look for terminal marks, scratched contacts, relay-use signs, replaced labels, or resealing.
|
|
Q3. How should a buyer verify that the supplier is legitimate and reliable?
Verify the supplier legal name, registration, address, contact details, and bank beneficiary. Request references for S7-1500 output modules and ensure every commercial document states 6ES7522-5HH00-0AB0.
|
|
Q4. Which specifications should an engineer verify before purchasing?
Confirm 24 V DC coil supply, 16 relay outputs, 24 to 230 V AC or 24 to 120 V DC load range, 2 A per channel, 4 A per group, grouping by two, front-connector type, and 35 x 147 x 129 mm dimensions.
|
|
Q5. What physical evidence should be requested before payment?
Request timestamped photos or video showing the full 6ES7522-5HH00-0AB0 label, housing, terminal area, included U-connector, package seals, and whether the separately ordered front connector is included in the offer.
|
|
Q6. Can a similar SM 522 suffix replace 6ES7522-5HH00-0AB0?
Not automatically. A different suffix can change relay or semiconductor output type, voltage, channel count, current, grouping, diagnostics, and safety-oriented shutdown behavior. Engineering must approve the wiring and load ratings.
|
|
PN:50123684-001FRE
|
CMD5B1000
|
SDV541-S33
|
|
iQEC035-1201U50004
|
E05016-2134
|
XFC3D06001
|
|
CK80
|
GC1600CH
|
S-B1008D-04
|
|
140CHS11000
|
ARV-006A-000
|
WLP150H
|
|
ESA047010 SM87HXB
|
GE IC200UEX734-D
|
MC55A0 MC55A0-P40SWQQA9WR
|
|
IMC-21-S-SC 3093015000081
|
A12-PC-LU ASCEND-12 BASE-12
|
8300-0-8103 / 2TMA070080W0009
|
|
BR6000-R12PH
|
CM82-EZ-II-BK
|
OG5121
|
|
ABB MTQ22-FBP.0 / 1SAJ260000R0100
|
Abb 3BSE038226R1
|
6ES7972-0DA00-0AA0
|
|
01-ELITEEXEC4
|
QLCC01
|
PD690-4-N
|
|
HUB800
|
FHX40 ,FHX40-21A
|
F15 1RU
|
|
6SE6400-3TC00-4AD2
|
1085-306 AN3100D
|
ABB 6814U-500
|
|
SR-0 8041299
|
9253C25G04
|
ZN341V
|
|
RSN4004
|
ECP-300
|
MTL5544S
|
|
PWR-125W-AC 341-0502-01
|
D950EF-00
|
CK721-A 27-5379-714
|
|
U891R
|
ABB M251022CR 800-0-8049
|
HLS-SE20J
|
|
KA-2000
|
EDS-510A-3GT
|
2CDG110056R0011
|
|
TXA204C
|
BMXP342000 CPU340-20
|
H2 4600
|
|
7NG4021-6AA33-1NA1
|
PRO/1000-F A38888-002
|
XDC-4000B
|
|
P32AF-2C
|
HMP-HM64-CC MTL4850
|
WB45-2E
|
|
BZME1-A80-BT
|
3718B004
|
GT5 AS E9733BA-01
|