Complete model
|
6ES7518-4JP00-0AB0
|
|
Product family
|
SIMATIC S7-1500H - CPU 1518HF-4 PN
|
|
Product type
|
Fail-safe redundant central processing unit
|
|
Dimensions
|
210 x 147 x 129 mm
|
|
Weight
|
Approx. 2,116 g
|
|
Supply voltage
|
24 V DC (19.2 to 28.8 V DC)
|
|
Current consumption
|
Rated 1.55 A; maximum 1.95 A
|
|
Power loss
|
Typically 24 W
|
|
Work memory
|
9 MB for program; 60 MB for data
|
|
Memory card
|
SIMATIC Memory Card required; maximum 32 GB
|
|
Bit processing time
|
Typically 4 ns
|
|
PROFINET interfaces
|
Three interfaces: X1 with 2-port switch; X2 and X3 with 1 port each
|
|
H-SYNC interfaces
|
Two pluggable fiber-optic synchronization interfaces
|
|
Ethernet
|
100 Mbps on all interfaces; 1000 Mbps additionally on X3
|
|
Connections
|
Maximum 384 connection resources
|
|
System redundancy
|
PROFINET S2 and R1 supported
|
|
Safety
|
PROFIsafe V2.4/V2.6; PLe; SIL 3
|
|
Operating temperature
|
Horizontal installation: 0 to 60 deg C; vertical installation: 0 to 40 deg C
|
|
Storage and transport
|
-40 to 70 deg C
|
|
Installation altitude
|
Maximum 5000 m; restrictions apply above 2000 m
|
|
Firmware and hardware
|
Firmware V3.1; hardware functional status FS04
|
|
Engineering software
|
TIA Portal V19 for firmware V3.1; V17 or higher for firmware V2.9
|
|
CONTACT
STELLA
|
|
Fail-safe redundant CPU
Combines high-availability redundancy with fail-safe automation functions.
|
High performance
Typical processing times are 4 ns for bit operations and 24 ns for floating-point arithmetic.
|
|
Large memory
Integrated work memory provides 9 MB for program and 60 MB for data.
|
Diagnostics
RUN/STOP, ERROR, MAINT, and LINK TX/RX LED indications are provided.
|
|
Functional safety
The CPU supports PLe according to ISO 13849-1 and SIL 3 according to IEC 61508.
|
PROFIsafe
PROFIsafe protocol versions V2.4 and V2.6 are supported.
|
|
System redundancy
Both PROFINET S2 and R1 system redundancy are supported.
|
Safe engineering
TIA Portal supports fail-safe LAD and FBD programming for this CPU.
|
|
PROFINET X1
RJ45 interface with two ports, integrated switch, PROFINET IO controller, and MRP.
|
PROFINET X2
RJ45 interface with one port and no integrated switch.
|
|
PROFINET X3
RJ45 interface with one port and support for 1000 Mbps.
|
H-SYNC
Two fiber-optic synchronization interfaces accept approved synchronization modules.
|
|
Horizontal installation
Permissible operating temperature is 0 to 60 deg C.
|
Vertical installation
Permissible operating temperature is 0 to 40 deg C.
|
|
Storage and transport
Permissible temperature is -40 to 70 deg C.
|
Altitude
Installation altitude is up to 5000 m, with restrictions above 2000 m.
|
|
Q1. How can I verify the quoted item is exactly 6ES7518-4JP00-0AB0?
Match the full Siemens article number on the quotation, nameplate, and packaging. Confirm CPU 1518HF-4 PN, 9 MB program memory, 60 MB data memory, three PROFINET interfaces, PROFIsafe, and two H-SYNC interfaces.
|
|
Q2. How can I distinguish New, Used, or Refurbished condition?
Request current photos of the factory label, serial data, FS04 marking, display, X1 to X3 ports, H-SYNC slots, power terminals, housing, and packaging. Require the offered condition in writing.
|
|
Q3. How can I check whether a supplier is legitimate and reliable?
Verify company registration, traceable address, matching bank beneficiary, business contact channels, and a formal quotation listing 6ES7518-4JP00-0AB0 in full with the stated condition.
|
|
Q4. Which specifications should an engineer verify before purchase?
Confirm 24 V DC supply, firmware and TIA Portal compatibility, SIL 3 and PLe requirements, S2 or R1 topology, H-SYNC modules, three PROFINET interfaces, 210 x 147 x 129 mm dimensions, and 2,116 g weight.
|
|
Q5. What physical evidence should I request before payment?
Ask for dated photos or video showing the full 6ES7518-4JP00-0AB0 label, serial data, FS04 or displayed firmware, X1 to X3 and H-SYNC connections, power connector, seals, and quantity.
|
|
Q6. Can a similar CPU 1518H or 1518HF suffix replace this model?
Do not assume interchangeability. A different suffix can change fail-safe capability, memory, firmware requirements, redundancy functions, H-SYNC configuration, interfaces, dimensions, and engineering compatibility.
|
|
CH-DIM4
|
MTL-5541
|
H4D1F1X
|
|
1605
|
UTG-1500
|
PROVIT 2500 HS09572214
|
|
ULX1-S3
|
AD188 104315
|
XC-ST30/XC-ST30/1
|
|
SCP08
|
NPT-8R0-0108-1
|
WGEN02KP1
|
|
RS-1180-0002
|
1321-3R25-B
|
501EN , 500495
|
|
PRC15
|
E12-C92-451
|
VROM-160 D59B AM2020/AFP-1010 / AFP-200 AFP-300/400
|
|
2791
|
2CDG110088R0011
|
QUINT-PS-100-240AC/24DC/5 2938581
|
|
ANMA213V2
|
U9500B2002006265-002
|
ABB GJR2237600R1 DT370A 9090/076
|
|
Z043.617/01
|
T6831A
|
AFP0RC32CP
|
|
F15R
|
FSP-951A
|
SMARTPACK2 242100.601
|
|
PFD-402-25
|
GCU-HOSP-1
|
5ST3 012
|
|
6ES7972-0BA12-0XA0
|
32-1115-03
|
RCP-64PB-OLED
|
|
rtu90 IMRCC02
|
CSE-200
|
ZSB-1.5/16-S/S
|
|
BK5200 KL4004 KL3064 KL9010
|
SPCK521.100-N
|
EZ-VDA2BX
|
|
EV8345G081
|
SRD-91
|
2000-RANGE
|
|
49Y7935 00D5803
|
CUBOID8-B
|
IS23DI0XCD000
|
|
BR6000-R06
|
PXA30-RS
|
ABB 3BSE020846R1 3BSE037760R1
|
|
C7973A LTO-3
|
PC0509-2 CIMR-POD45P5AH-E YPCT31513-1B
|
E9911111111111111
|
|
FGD-1400
|
Tr-cy / 500cc
|
6970
|
|
1SAP120600R0001
|
TSW-552-BS
|
26348
|