TERMINAL TYPE
Spring-type
|
SLOTS
Up to 8
|
|
CURRENT CAPACITY
Maximum 8 A
|
MODULE SIZE
145 × 100 × 40.5 mm
|
|
LEAD TIME
In stock
|
WARRANTY
1 year
|
Module carrier and termination
Provides the spring-terminal base for installing compatible analog and digital SIMATIC SC electronic submodules.
|
Multi-slot expansion
Accommodates up to eight single-width slots in the documented hardware configuration.
|
Power distribution
Carries up to 8 A through 1L+ and 2L+, subject to the 1.5 A-per-slot parallel-feed limit.
|
Legacy station service
Supports maintenance of existing SIMATIC SC / ET 200L-SC stations that use the TB16SC format.
|
|
Complete model
|
6ES7120-0BH01-0AA0
|
|
Brand
|
Siemens
|
|
Product family
|
SIMATIC SC / ET 200L-SC
|
|
Product type
|
TB16SC terminal block
|
|
Terminal technology
|
Spring-type terminals
|
|
Application
|
Expansion with analog and digital SC electronic modules
|
|
Single-width slots
|
Maximum 8
|
|
Current-carrying capacity
|
Maximum 8 A via 1L+ and 2L+
|
|
Parallel-feed limit
|
Maximum 1.5 A per slot
|
|
Isolation test voltage
|
4000 V DC
|
|
Dimensions
|
145 × 100 × 40.5 mm (W × H × D)
|
|
Weight
|
Approximately 230 g
|
|
Lifecycle
|
Spare part; discontinued product
|
|
Module carrier and termination
Provides the spring-terminal base for installing compatible analog and digital SIMATIC SC electronic submodules.
|
|
Multi-slot expansion
Accommodates up to eight single-width slots in the documented hardware configuration.
|
|
Power distribution
Carries up to 8 A through 1L+ and 2L+, subject to the 1.5 A-per-slot parallel-feed limit.
|
|
Legacy station service
Supports maintenance of existing SIMATIC SC / ET 200L-SC stations that use the TB16SC format.
|
|
Terminal method
|
Spring-type connection
|
|
Module positions
|
Up to 8 single-width slots
|
|
Supply paths
|
1L+ and 2L+
|
|
Maximum total current
|
8 A
|
|
Maximum parallel-fed slot current
|
1.5 A per slot
|
|
Isolation qualification
|
Tested at 4000 V DC
|
|
1 · Identify the station
Confirm the installed system uses the SIMATIC SC TB16SC mechanical and electrical format.
|
|
2 · Plan the module set
Count the required single-width analog and digital SC modules; the official limit is eight slots.
|
|
3 · Calculate loading
Verify the total 1L+/2L+ current and the 1.5 A maximum per parallel-fed slot.
|
|
4 · Prepare spring terminals
Use conductor preparation and wiring practices specified for the installed SIMATIC SC station.
|
|
5 · Inspect the assembly
Check terminal retention, polarity, module seating and supply distribution before energizing.
|
|
Module family
Designed for compatible analog and digital SIMATIC SC electronic modules.
|
|
Slot format
Accepts up to eight single-width module positions.
|
|
Electrical loading
The connected module set must remain within the 8 A total and 1.5 A-per-slot limits.
|
|
Terminal variant
This 0BH01 model uses spring terminals; screw-terminal TB16SC variants are not identical replacements.
|
|
Q1 · How is the exact terminal block verified?
Match 6ES7120-0BH01-0AA0 and the TB16SC spring-terminal description on the label, photos and quotation. Do not accept only the shortened TB16SC name.
|
|
Q2 · How can New, Used or Refurbished condition be distinguished?
Inspect current photos of every spring terminal, the module slots, supply markings and enclosure. Bent contacts, conductor residue, tool marks or repaired latches should be disclosed.
|
|
Q3 · How should a supplier be qualified?
Verify its legal identity, payment beneficiary and traceable transaction process, then require the official Siemens one-page data sheet tied to the complete part number.
|
|
Q4 · What must engineering check before ordering?
Confirm the SIMATIC SC platform, spring-terminal requirement, eight-slot capacity, 8 A total limit, 1.5 A-per-slot limit and mechanical dimensions.
|
|
Q5 · What evidence should be requested before payment?
Request dated front, rear and terminal close-ups showing the complete code, supply rails, all slot positions and packaging condition.
|
|
Q6 · Can a similar TB16SC suffix be substituted?
Not automatically. Spring and screw terminal versions differ, and supply distribution, slot arrangement and mechanical fit must be checked against the installed station.
|
|
C2N-SSC-2
|
6GK5208-0BA10-2AA3
|
310-00 DALI-O-GRAM
|
|
RM8I
|
ABB 2CDG120041R0011
|
ABE7H16R21
|
|
50PLC-M03
|
DC374E 420 269 R1
|
MFMP40
|
|
AN-WF100
|
PM8210 METSEPM8210
|
AC-1 plus / AC -1PLUSFT
|
|
SCM268 SCM268E
|
CKA-37 H-7PRCD 0861G - PC4404
|
ABB 6127/01-866-500 2CKA006117A0227
|
|
D-67722, MX-SM-N25-PW
|
Z1008
|
CLIOL823A
|
|
DMC-4K-C-HDCP2
|
TM168B23S
|
AS-221OA
|
|
TM3TI4DG TM3-4
|
HG-00007
|
EIR308
|
|
DC30
|
CLTG38EXPN01
|
TR-7000
|
|
A1SY10EU
|
TM171AETH
|
DUS360CR
|
|
OLS250220
|
QBM3020-1U
|
GGD126.1U 142LB-IN
|
|
MI-890
|
IBIL24DO4
|
IB-150 99-000008-02
|
|
ABB 68249660 VHP-5
|
ABB 1MRK002266-AAr00
|
DRC410F
|
|
J6-152
|
AMP-320-EUR
|
ABB RTXP18 RK926115-BG
|
|
GPA2 3BA23241AAAC
|
TVG430
|
InBIO160
|
|
633B1 E231024193804
|
CDIB-VASX-SI-10
|
MA1500
|
|
PSU36-3A-DIN
|
F0.95
|
GJR2340200R1 DT384A 9081/011
|
|
REF.04813
|
6ES7197-1LB00-0XA0
|
GX100MG
|
|
OP10HONE
|
REG-K/8x10
|
LEM-3
|
|
D4-L MF6FTJ0026
|
102F
|
SNM800
|