Purpose
6SL3162-2MA00-0AC0 provides the detachable power connection between field motor conductors and SINAMICS S120 Booksize C/D-type Motor Modules.
|
Connection range
The screw-terminal design accepts conductor cross-sections from 0.75 to 6 mm² and supports Motor Modules in the 3 to 30 A output-current range.
|
Terminal functions
The connector integrates U2, V2 and W2 motor phases, PE protective conductor, and BR+ / BR- holding-brake terminals in one assembly.
|
Selection identity
This exact 2MA screw-terminal variant is distinct from the 2MB push-in connector. Match the complete part number before purchase or replacement.
|
|
Complete model
|
6SL3162-2MA00-0AC0
|
|
Brand
|
Siemens
|
|
Product family
|
SINAMICS S120
|
|
Product type
|
C/D-type power connector
|
|
Compatible equipment
|
Booksize C/D-type Motor Modules
|
|
Rated module output-current range
|
3 to 30 A
|
|
Connection method
|
Screw terminals
|
|
Permissible conductor cross-section
|
0.75 to 6 mm²
|
|
Motor phase terminals
|
U2, V2 and W2
|
|
Protective conductor terminal
|
PE
|
|
Holding-brake terminals
|
BR+ and BR-
|
|
Required tool
|
Slotted screwdriver 0.8 × 4.0 mm
|
|
Quantity unit
|
1 piece
|
|
Lifecycle status
|
PM300 active product
|
|
Country of origin
|
Germany
|
|
Dimensions
|
Not specified in the official Siemens product data sheet
|
|
Weight
|
0.033 kg
|
|
Approval
|
cULus-approved connection plug
|
|
RoHS conformity
|
Since 2015-10-01
|
|
UPC
|
804766199608
|
|
Motor power termination
Provides the detachable field termination point for U2, V2 and W2 motor phases on compatible Booksize C/D-type Motor Modules.
|
|
Protective conductor path
Includes a dedicated PE terminal so the protective conductor is connected through the specified power-connector assembly.
|
|
Holding-brake wiring
BR+ and BR- terminals support the motor holding-brake circuit where the selected drive and motor configuration uses this function.
|
|
Service replacement
Suitable as a model-specific replacement connector when the existing assembly, terminal hardware or housing must be renewed.
|
|
Motor phases
|
U2, V2 and W2
|
|
Protective conductor
|
PE
|
|
Holding brake
|
BR+ and BR-
|
|
Terminal technology
|
Screw connection
|
|
Conductor capacity
|
0.75 to 6 mm²
|
|
Connector form
|
C/D-type for Booksize modules
|
|
Installation tool
|
Slotted screwdriver 0.8 × 4.0 mm
|
|
1 · Verify the module
Confirm that the target unit is a SINAMICS S120 Booksize C/D-type Motor Module in the specified 3 to 30 A range.
|
|
2 · Isolate energy
De-energize the drive system and observe the waiting times and safety instructions stated in the applicable Siemens equipment manual.
|
|
3 · Prepare conductors
Use conductors within the documented 0.75 to 6 mm² range and prepare them according to the Siemens wiring instructions.
|
|
4 · Terminate correctly
Connect U2, V2, W2, PE and, when required, BR+ and BR-. Tighten the screw terminals with a 0.8 × 4.0 mm slotted screwdriver.
|
|
5 · Inspect before energizing
Check conductor seating, PE continuity, terminal assignment and connector retention before restoring power.
|
|
Specified range
6SL3162-2MA00-0AC0 is documented for SINAMICS S120 Booksize C/D-type Motor Modules rated 3 to 30 A.
|
|
Screw versus push-in
The 2MA model uses screw terminals. Siemens lists 6SL3162-2MB00-0AC0 as the separate push-in counterpart; the two versions should not be treated as identical.
|
|
Double Motor Modules
Where a Double Motor Module requires two power connectors, Siemens specifies two identical connector variants for the assembly.
|
|
Procurement check
Match the full Siemens part number, frame type, connection technology and conductor range to the installed module and approved wiring design.
|
|
Q1 · How can I verify that the quotation covers the exact model?
Require the full part number 6SL3162-2MA00-0AC0 on the quotation, product label and photos. The 2MA code identifies the screw-terminal version; a shortened code is not sufficient.
|
|
Q2 · How can New, Used and Refurbished condition be distinguished?
Ask for current close-up photos of the housing, latch, screw terminals and conductor entries. Contact marks, tool wear, residue, damaged terminal screws or replaced packaging should be disclosed before purchase.
|
|
Q3 · How should I assess whether the supplier is legitimate and reliable?
Verify the legal company identity, business contact details, bank-account beneficiary and order documentation. A qualified supplier should link the offer to official Siemens documentation and provide traceable evidence for the exact part.
|
|
Q4 · What must engineering confirm before ordering?
Confirm a SINAMICS S120 Booksize C/D-type Motor Module, the 3 to 30 A module range, screw-terminal connection, 0.75 to 6 mm² conductor size and the required U2/V2/W2, PE and BR+/BR- assignments.
|
|
Q5 · What physical evidence should be requested before payment?
Request dated photos of the complete connector, the Siemens label or packaging, all screw terminals, the latch and the conductor-entry side. The evidence should show the same item and full model stated in the offer.
|
|
Q6 · Can a similar connector or suffix be substituted?
Do not assume interchangeability. The 6SL3162-2MB00-0AC0 push-in version uses different terminal technology, and Double Motor Modules require identical connector variants. Any change must be checked against the installed module and wiring design.
|
|
T8313 5020-301
|
3SB3400-0A
|
6SL3211-0AB12-5UA1 6SL3255-0AA00-4BA1
|
|
VS00P10KNX
|
MMC-QR030024-02LD00A
|
ABB 1SAP250600R0001 AI531 1SAP212200R0101
|
|
B578 201-104-P12-RA0
|
174-Q
|
T-ASH-G2-100
|
|
T-100-G
|
D-1101-RSG2100 RJ45TX01
|
PM-7200-8TX
|
|
189784 KFD2-EB2.R4A.B
|
MSR142RTP 440R-G23215
|
ER40 82120AKI000
|
|
IM1-12EX-T
|
ABB 1SAP221100R0001 CI590-CS31-HA
|
SDB-Tn10-20-1
|
|
R7651191 / R7651191-03
|
SYS-7850 NSG-C
|
BF-50
|
|
512BPS
|
ABB PSM0004 2RCA025059A0001N
|
CAM301
|
|
2865120_ PI-EX-DO
|
54Y2537
|
ST-122F
|
|
LC1F115
|
P8 R 8 DIN - 8
|
S904
|
|
GE CR104PLG92M
|
TP57AT/703049
|
abb 2RCA023019A0003K 2RCA023009M
|
|
CRT1-MD16-1
|
10B-PCTA
|
sg001043
|
|
DDS-12MHz
|
SEC-TEA-230-5045
|
CC-PAIH01 51405038-175
|
|
SB500
|
ABB 1SAZ211201R1031 Ta25DU-3.1
|
G06A719A01
|
|
INT-1630-L-1-M-070
|
ATC4001AWI/T
|
VEP1485
|
|
140DDI35300
|
PZ16 9012600000
|
2CDG 110171R0011
|
|
140XBE10000
|
EH-D28DRP
|
RAVG-1
|
|
HPBYB6FF 316SS-PTFE
|
100 G3
|
POL965.00 MT3025
|
|
UC8
|
QTERM-N15 N061
|
P9XPNRG P9XLRD P9XLGD P9B01VN P9B10VN
|
|
ABB 3BSE008508R1 DI810
|
AR502EGRz-L
|
NeOSS-V3-16A
|