| Model | 3501E |
| Module type | TMR digital input |
| Input points | 32 |
| Input isolation | Optically isolated |
| Input commoning | Non-commoned |
| Nominal voltage | 115 V AC/VDC |
| Operating range | 90 to 155 V AC/VDC |
| Frequency range | DC or 47 to 63 Hz |
| Maximum input voltage | 155 V AC/VDC |
| Guaranteed off-to-on level | At or above 86 V AC/VDC |
| Guaranteed on-to-off level | At or below 28 V AC/VDC |
| Nominal turn-on current | 6 to 9 mA |
| Typical hysteresis | 32 V AC/VDC |
| Off-to-on delay | Less than 8 ms |
| On-to-off delay | Less than 15 ms |
| Point isolation | 1500 V DC |
| Nominal input impedance | More than 8.5 kΩ |
| Power per active point | 1.5 W |
| Power at maximum field voltage | 2.9 W |
| Point status indicators | One per input |
| Module status indicators | PASS, FAULT and ACTIVE |
| Stuck-on test | Not provided |
| Hot-spare capability | Supported |
| External termination panel | Required |
| Color code | Red |
| Commoned panel options | 9561-810F |
| Non-commoned panel options | 9561-110F |
| Basic panel option | 9551-110F |
| Fanned-out cable option | 9101-010F |
| ERT loopback option | 9141-010F |
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
3501E is a Triconex Tricon TMR digital input module for thirty-two isolated 115 V AC or DC field points. Every input is non-commoned, allowing separate field circuits across the module. The operating range extends from 90 to 155 V AC/VDC, with AC operation from 47 to 63 Hz.
Three independent input channels scan and condition each signal before the Tricon Main Processors perform the final vote. Optical barriers separate the high-voltage field wiring from the controller electronics. Individual point indicators and PASS, FAULT and ACTIVE module indicators expose both process state and diagnostic condition.
When replacing the module, retain the non-commoned termination arrangement and the isolation boundary for each channel. Confirm AC or DC field voltage, conductor identification and panel compatibility before transfer. Because the 3501E does not use the grouped-input stuck-on test, validation should include direct off-state and on-state checks for every assigned point.
| V28410A-1101100 | DM4T 4940275 | MX-9.14104.1.1.0 |
| EY-IO551F001 | C65-MW-K LNL-C65-MW-K | AL600XB220 |
| MWR-SH11UN | ETOR-4 | SK-140TRH |
| ATW-RC13 | V1405-24 | PG320240WRT-MNN-IQ |
| CCT15369 | UDS1100002-01 | DIS DC 6120 |
| T9600-TF21-1JS0 T9000 | A160048-00 | OAW-AP1201H |
| M-IN-M201.07 | APG0001-0701E | C65-MW-K |
| KTXL-116G-16 | PB-16DI | CLAXEH00ND100A |
| PCO3000AS0 | QSNE-2DAL-D | C2IR-8 6500429 |
| STB4D-10 | RXV-35-4K | LJ-G5001 |
| MSC445-010-00-A | PCD7.D230 | CRC3044BC |
| NC3FD-LX | CM82-EZ-II-BK | Brady 76627 |
| Mtl45/46/5500 | TV-IP612P | LNL-2220 |