| Model | 3505E |
| Module architecture | Triple modular redundant |
| Input function | Low-threshold digital input |
| Nominal input voltage | 24 V DC |
| Input points | 32 |
| Commoning | Groups of 8 |
| Operating input range | 20 to 42.5 V DC |
| Maximum input voltage | 42.5 V DC |
| Guaranteed off-to-on level | At or above 12 V DC |
| Guaranteed on-to-off level | At or below 4 V DC |
| Nominal turn-on current | 3 to 5 mA |
| Typical hysteresis | 2 V DC |
| Off-to-on delay | Less than 8 ms |
| On-to-off delay | Less than 15 ms |
| Point isolation | 1500 V DC |
| Nominal input impedance | More than 1.25 kΩ |
| Field load per active point | 0.5 W |
| Field load at maximum voltage | 1.5 W |
| Input status indication | One indicator per point |
| Module indicators | PASS, FAULT and ACTIVE |
| Stuck-on test | Enabled |
| Hot-spare support | Provided |
| External termination panel | Required |
| Module color code | Dark red |
| Commoned termination panels | 9563-810F / 9563-910F |
| Basic termination panel | 9553-610F |
| Nonincendive termination panel | 9572-610F |
| Fanned-out cable | 9101-010F |
| Bypass panel | BP9228-010F |
| ERT loopback panel | 9143-010F |
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
3505E is a Triconex Tricon low-threshold digital input module with thirty-two 24 V DC points commoned in groups of eight. Three independent channels process each field state and deliver the results to the Main Processors for voting. The 20 to 42.5 V DC input range and 3 to 5 mA nominal turn-on current suit low-energy contact and sensor circuits.
A built-in stuck-on test checks whether an energized input can return to the off state without disrupting the last value presented to the control program. Optical isolation separates field wiring from the Tricon controller, while channel diagnostics report faults through the chassis alarm path. One indicator per input supports rapid point-level inspection.
Replacement requires the correct commoned termination-panel arrangement because the thirty-two channels share field references in groups of eight. Verify input polarity, group commons, low-threshold switching behavior and channel mapping before commissioning. The keyed chassis position and hot-spare configuration must match the existing Tricon installation.
| APJ6385 | HS2032PCBCE | HHU32100 |
| EIR608-4SFP | OD7685/OD7685.12 | HDP5000 |
| CPP40 | DMPU-R2 | IAP-215-RW |
| ICP11I0350000 | AR-133 | MTL4031 |
| DM01D01ACC | WS-2 02738C2 | DR-120-24 |
| ATA4S-00 | EMC2 API4SG10 712G p/n 071-000-521 | SIM-CNR04E |
| RS8-L-DIN | PIG00032 | ADC8220/22 |
| OAW-AP1201H-RW | VC7936ZZ11/U | D-1101-RSG2100 RJ45TX01 |
| WMS-617-321 | RB2 BD2 | FST-951A-IV |
| C-MAP M-IN-M201.07 | A08 TK S014 | TXA207D |
| SB-9in1T-CL | ULFIM-D37M-45-XOR | VZ0008.BD4 |
| HD251X 620TVL | AWK-5222 | DM4T KNX 4940275 |
| EVD0000E51 | RX399 PIWW360BT | LNL-C65-MW-K |