Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
triconex 3617e 8 point 48 v dc supervised digital output module-0

Triconex Invensys

Home >  Products >  SCHNEIDER >  Triconex Invensys

Triconex 3617E 8-Point 48 V DC Supervised Digital Output Module

TRICONEX
TRICON
8 DO · 48 V DC
3617E
Product Name: Supervised Digital Output Module
Brand Name: Triconex
Model Number: 3617E
Place of Origin: USA
Warranty: 12 Months
DIRECT PRODUCT ENQUIRY
WhatsApp: +86 18020776782
Appurtenance
  • Overview
  • Specifications
  • Commercial Terms
  • Description
  • Supervised Output Voting
  • Critical Output Diagnostics
  • FAQ
  • After-Sales Support
  • Other Products
  • Recommended Products
SALES CONTACT
Jim Pei
Industrial automation support
EMAIL
Send your model and quantity
PHONE / WHATSAPP
Fast quotation and order support

Specifications

8 points · 48 V DC · TMRTMR supervised digital output · 8 commoned · 48 V DC
Model 3617E
Output type TMR supervised digital output
Output points 8 commoned
Nominal voltage 48 V DC
Operating voltage range 36–72 V DC
Maximum switching power 150 W resistive
On-state voltage drop Less than 2 V typical
Maximum point current 1 A
Pulse current rating 5 A for 10 ms
Minimum required load 100 mA
Secondary supply 5.00 V DC ±0.25 V DC
Maximum load leakage 4 mA
Field termination fuses 1.25 A fast-acting, one per output
Point isolation 1500 V DC minimum
Output status indicator POINT
Field power indicator PWR
Load alarm indicator LOAD
Module indicators PASS, FAULT, ACTIVE
Color code Mint green
Hot-spare capability Supported
Required termination Separate external termination panel

Commercial Terms

Minimum Order Quantity 1 Piece
Price Contact for Jim
Packaging Details Original new Factory Sealed
Delivery Time 3–7 Days
Payment Terms T/T
Shipping Method DHL / FedEx / UPS / TNT
Supply Ability Brand new, In Stock

Description

01
3617E is a Triconex eight-point supervised digital output module for 48 V DC field circuits. Three processor output channels are voted by a fault-tolerant output switch before the selected state reaches the commoned field outputs. Voltage and current loopback extend diagnostics from the module electronics into the connected load circuit.
02
3617E The module can identify loss of field power, an open or missing load and a field short that could energize a deactivated load. A secondary supply supports additional off-state short detection. Hot-spare operation and a separate external termination panel allow the module to be serviced within a properly configured Tricon system.

Supervised Output Voting

01
Triplicated command
Three processor channels deliver independent output states.
02
Fault-tolerant vote
The quadruplicated switch votes the three commands.
03
Field energization
The selected state drives one of eight 48 V DC outputs.
04
Loopback supervision
Voltage and current feedback verify the switch, wiring and load.

Critical Output Diagnostics

01Long-held trip states
Supervises outputs that may remain unchanged for extended periods.
02Power-circuit alarms
Detects loss of field voltage or a blown termination fuse.
03Load continuity
Identifies an open or missing field load.
04Hot-spare maintenance
Supports online replacement with the configured spare position.

FAQ

QUESTION 01
Which field voltage is supervised by Triconex 3617E?
The module is designed for 48 V DC circuits operating within 36 to 72 V DC.
QUESTION 02
What faults can Triconex 3617E detect beyond internal electronics?
It supervises field power, load presence and a short that could energize a load in the off state.
QUESTION 03
Why does Triconex 3617E use output voting?
Three processor commands are voted so a single faulty channel does not directly determine the field state.
QUESTION 04
What minimum load is required by Triconex 3617E?
The supervised output specification requires a minimum 100 mA load.
QUESTION 05
Which fuse rating is used with Triconex 3617E termination?
Each output uses a 1.25 A fast-acting fuse on the field termination.
QUESTION 06
Can Triconex 3617E be maintained with a hot spare?
Yes. The module supports hot-spare operation with the required external termination arrangement.

After-Sales Support

01 WARRANTY ASSISTANCE Warranty support is available for product-quality concerns during the agreed 12-month period.
02 RESPONSIVE TECHNICAL SUPPORT Our team responds promptly to product, installation and compatibility questions.
03 ORDER TRACKING Clear order-status and shipment updates are provided from payment through dispatch.
04 GLOBAL CUSTOMER SERVICE International customers receive consistent communication throughout purchasing and after-sales service.
05 LONG-TERM SPARE PARTS SUPPORT We continue sourcing discontinued and hard-to-find automation components for maintenance requirements.

Other Products

V28410A-1101100 DM4T 4940275 MX-9.14104.1.1.0
EY-IO551F001 C65-MW-K LNL-C65-MW-K AL600XB220
MWR-SH11UN ETOR-4 SK-140TRH
ATW-RC13 V1405-24 PG320240WRT-MNN-IQ
CCT15369 UDS1100002-01 DIS DC 6120
T9600-TF21-1JS0 T9000 A160048-00 OAW-AP1201H
M-IN-M201.07 APG0001-0701E C65-MW-K
KTXL-116G-16 PB-16DI CLAXEH00ND100A
PCO3000AS0 QSNE-2DAL-D C2IR-8 6500429
STB4D-10 RXV-35-4K LJ-G5001
MSC445-010-00-A PCD7.D230 CRC3044BC
NC3FD-LX CM82-EZ-II-BK Brady 76627
Mtl45/46/5500 TV-IP612P LNL-2220

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000