Vibro-meter CP235 143-235-000-012 Piezoelectric pressure transducer In stock

Product Name:Piezoelectric pressure transducer

Brand Name:Vibro-meter

Model Number:CP235 143-235-000-012

Country of Origin:Switzerland

Warranty:12 Months

Whatsapp+86 18159889985

Email[email protected]

Appurtenance:
  • Overview
  • Contact for quotation
  • Specifications
  • Description
  • Applications
  • Features
  • Functions
  • FAQ
  • Spares
  • Recommended Products

Overview

Brand Name:

Vibro-meter

Model Number:

CP235 143-235-000-012

Country of Origin:

Switzerland

Packaging Details:

Original new Factory Sealed

Delivery Time:

in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Item Description
Model CP235 143-235-000-012
Product Type Piezoelectric pressure transducer
Brand Vibro-Meter®
Output Signal Charge output (2-pole insulated system)
Sensitivity ≥ 750 pC/bar
Frequency Range 2 Hz – 10,000 Hz
Operating Temperature -55°C to +520°C
Static Pressure Range 0.1 – 20 bar
Dynamic Range 0.00005 – 5 bar (nominal)
Overload Capacity Up to 100 bar (spikes)
Linearity ≤ ±1%
Dimension Ø18 mm × 65 mm (sensor head approx.)
Weight 50 g (head), 140 g/m (MI cable)

Description

The CP235 143-235-000-012 is a high-performance piezoelectric pressure transducer developed for demanding gas turbine and industrial monitoring applications. Designed under the Vibro-Meter® product line, the CP235 delivers highly stable dynamic pressure measurement with strong resistance to vibration and acceleration effects, ensuring accurate signal output in critical environments.

Built with advanced man-made piezoelectric sensing technology, the CP235 143-235-000-012 provides exceptional long-term stability and reliability. Its acceleration-compensated structure significantly reduces measurement distortion, making it suitable for both continuous monitoring and experimental testing in high-temperature machinery systems.

With certified intrinsic safety options and robust construction for extreme operating conditions, the CP235 143-235-000-012 is widely used in gas turbines, power generation, and hazardous industrial zones where precise pressure measurement and operational safety are essential.

Applications

Power plants: Used for generator set status monitoring and relay protection.
Substations: Enable bus differential control, line protection, and switchyard signal acquisition.
Chemical plants: Integrate process control automation and intrinsically safe signal monitoring.
Steel mills (metallurgical plants): Perform equipment logic control in harsh environments with high temperatures and strong electromagnetic interference.
Machinery manufacturing plants: Used for automated production lines, robotic workstations, and packaging equipment control.

Features

• Acceleration-compensated piezoelectric sensing design
• Wide temperature operation up to 520°C
• Certified for explosive and hazardous environments (Ex approved)
• High sensitivity for low-level dynamic pressure detection
• Robust MI cable construction for harsh industrial use

Functions

• Converts dynamic pressure into stable charge signals
• Reduces vibration and acceleration-induced measurement errors
• Supports long-term industrial monitoring and testing
• Ensures safe operation in gas turbine environments
• Provides high-frequency response for transient pressure analysis

FAQ

Q1: What is CP235 143-235-000-012 used for?
A1: It is used for dynamic pressure measurement in gas turbines, power plants, and industrial monitoring systems.

Q2: Can CP235 operate in high-temperature environments?
A2: Yes, it supports continuous operation up to 520°C in harsh industrial conditions.

Q3: Is CP235 suitable for hazardous areas?
A3: Yes, it is certified for use in potentially explosive atmospheres with Ex protection versions.

Q4: What type of signal output does CP235 provide?
A4: It provides a charge output signal using a 2-pole insulated system.

Q5: What makes CP235 reliable in vibration-heavy applications?
A5: Its acceleration-compensated design minimizes vibration sensitivity and improves measurement stability.

Spares

900R12-0300

900R08R-0300

900R12R-0300

900R01-0300

900PSM-0200

900S75-0460

900S50-0460

900P01-0501

900P24-0501

900C70-0460

900C50-0460

900C30-0460

900RR0-0300

900C75-0560

900RSM-0200

900C70S-0460

900C50S-0460

900C30S-0460

900RR0-0300

900C75S-0560

900RSM-0200

900S75S-0460

900S50S-0460

900P01-0601

900P24-0601

900U02-0100

900A01-0202

900A16-0103

900B01-0301

900B08-0202

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000