abb ac500 s sm560 s fd 4 safety processor module with f device functionality for 4 profisafe networks original new-0

ABB

Home >  Products >  ABB

ABB AC500-S SM560-S-FD-4 Safety Processor Module with F-Device Functionality for 4 PROFIsafe Networks | Original New

ABB AC500-S SAFETY AUTOMATION
SM560-S-FD-4
Safety processor module for up to SIL 3 with F-Device functionality for up to 4 PROFIsafe networks.
ABB ARTICLE NUMBER: 1SAP286100R0001
PROGRAM MEMORY: 1.3 MB
SUPPLY: 24 V DC (-15 %, +20 %)
KEY CAPABILITY: Up to 4 PROFIsafe F-Host connections
LEAD TIME: In stock   |   WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications
  • Interfaces
  • Safety Functions
  • Installation
  • FAQ
  • Recommend Models
  • Recommended Products
ABB AC500-S / SAFETY CPU
SM560-S-FD-4
Safety processor module with F-Device functionality for up to four PROFIsafe networks.
Exact Configuration

ABB article number 1SAP286100R0001 identifies the non-XC SM560-S-FD-4 variant. It combines AC500-S safety CPU functions with a 1.3 MB safety program memory and PROFIsafe F-Device operation for up to four controller connections.

Functional Safety
Designed for applications up to SIL 3 according to IEC 61508, maximum SIL 3 according to IEC 62061, and PL e according to ISO 13849-1.
System Integration
The safety CPU mounts on the left side of a compatible non-safety AC500 CPU on the same terminal base and uses that CPU for engineering communication routing.

Technical Data

OFFICIAL CONFIGURATION DATA
ABB 1SAP286100R0001
Complete model
SM560-S-FD-4
ABB article number
1SAP286100R0001
Product family
ABB AC500-S
Product type
Safety processor module / safety CPU
Safety level
Up to SIL 3 (IEC 61508); max. SIL 3 (IEC 62061); PL e (ISO 13849-1)
PROFIsafe F-Device capacity
Up to 4 PROFIsafe networks
User program memory
1.3 MB
User data memory
1 MB, including 120 kB saved
Cycle time - binary
0.05 microseconds per instruction
Cycle time - word
0.06 microseconds per instruction
Cycle time - floating-point
0.50 microseconds per instruction
Process and supply voltage
24 V DC (-15 %, +20 %), without ripple
Absolute supply limits
19.2 ... 30 V DC, including ripple
Operating temperature
0 ... +60 deg C
Storage temperature
-40 ... +85 deg C
Mounting
Horizontal; vertical with maximum operating temperature derated to +40 deg C
Protection rating
IP20
Dimensions
28 x 135 x 75 mm (W x H x D)
Weight
Approximately 100 g
Certifications
CE, cUL

Applications

DEPLOYMENT PROFILE
Safety control for complex PROFIsafe architectures
01Multi-controller safety communication
The FD-4 variant provides F-Device functionality for connection to as many as four PROFIsafe F-Hosts, supporting safety architectures that require multiple controller relationships.
02High-integrity machine functions
Its safety CPU is intended for applications up to SIL 3 and PL e, where validated safety logic and deterministic execution are required.
03AC500-S system expansion
The module operates with an AC500 non-safety CPU on the same terminal base and can be combined with the AC500-S safety I/O platform.
04Structured engineering workflow
Safety applications are programmed with the AC500-S Programming Tool and engineering communication is routed through the associated non-safety CPU.

Interfaces

COMMUNICATION PATHS
PROFIsafe F-Device and AC500 system integration
F-Device operation
SM560-S-FD-4 can communicate as a PROFIsafe F-Device with up to four F-Hosts. This differentiates it from the FD-1 variant, which supports one F-Host.
Address setting
The front rotary address/configuration switches are used for the PROFIsafe F_Dest_Add settings of F-Device instances.
Engineering route
Programming communication is routed through the associated AC500 non-safety CPU using its serial interface or Ethernet connection.

Safety Functions

VALIDATED SAFETY PLATFORM
Configuration integrity and continuous diagnostics
Safety capability
Applications up to SIL 3 under IEC 61508, maximum SIL 3 under IEC 62061, and PL e under ISO 13849-1.
Program identity
Each safety CPU variant has its own product identifier; firmware detects a boot-project download intended for a different product variant.
Runtime tests
Start-up and runtime tests supervise program flow, RAM, CPU and other internal resources.
Execution capacity
The FD variants provide 1.3 MB of user program memory while retaining the AC500-S safety CPU feature set.

Installation

SYSTEM PLACEMENT
Terminal-base mounting and power requirements
1.Position the safety CPU on the left side of the compatible AC500 non-safety CPU on the same terminal base.
2.Use the specified 24 V DC process and supply voltage; official limits are 19.2 ... 30 V DC including ripple.
3.Use PELV or SELV power supply units and maintain the IP20 enclosure conditions required by the installed PLC system.
4.Mount horizontally for the full 0 ... +60 deg C operating range. Vertical mounting requires derating to a maximum of +40 deg C.
5.Set the front rotary switches according to the required address/configuration and verify the exact SM560-S-FD-4 product identifier before loading the safety project.

FAQ

PROCUREMENT AND ENGINEERING CHECKS
Six model-specific questions
Q1How can a buyer confirm the quoted unit is exactly SM560-S-FD-4?
A1. Check the complete type code SM560-S-FD-4 and ABB article number 1SAP286100R0001 on the nameplate, packaging and quotation. The FD-4 designation must not be shortened because it identifies support for up to four PROFIsafe F-Hosts.
Q2How can New, Used or Refurbished condition be distinguished for this safety CPU?
A2. Request current photos of the sealed packaging, module label and connector areas. A condition claim should be supported by traceable labeling, consistent serial information and clear disclosure of any prior installation or repair.
Q3How should the supplier be verified before purchasing SM560-S-FD-4?
A3. Verify the supplier legal entity, business address, payment beneficiary and industrial automation trading record. Ask for a written quotation that states SM560-S-FD-4, 1SAP286100R0001 and the offered condition without substitutions.
Q4Which specifications should engineers review before approval?
A4. Confirm the 24 V DC supply range, 28 x 135 x 75 mm dimensions, approximately 100 g weight, IP20 protection, 0 ... +60 deg C operating range, 1.3 MB safety program memory and the requirement for up to four PROFIsafe F-Host connections.
Q5What physical evidence should be requested before payment?
A5. Request time-stamped images of the actual module, front label, article number 1SAP286100R0001, terminals, rotary switches, packaging and serial markings. The evidence should be tied to the quotation and shipment lot.
Q6Can SM560-S, SM560-S-FD-1 or an XC variant replace SM560-S-FD-4?
A6. Not automatically. The FD-4 variant has a distinct product identifier and supports up to four PROFIsafe F-Hosts; FD-1 supports one, while XC versions use different article numbers and environmental specifications. Any change requires safety-system engineering validation.

Recommend Models

RECOMMEND MODEL
530E-JBS4N-017DL
KJ4006X1-BK1
5X00301G01
SPDSI14
KL3031X1-BA1
1C31194G01
SE4002S1T2B6
V18345-1010521001
AAI543-S50
IMASI23
ASI23
369B1848G5007
KL2001X1-BA1
KJ3243X1-BB2
5X00453G01
SS4307T01
TPS02
KC3020X1-BK1
1X00781H01L
KJ2221X1-EA1
CR300
KJ1501X1-BC5
KJ1501X1-BC4
5X00300G01
DHF-504B
KL3007X1-BA1
KJ4001X1-CC1
1C31192G01
VE4027
IMSED01
PHARPS32200000AB
MPU55
5X00784G01G01
5X00167G01
HFZ25
KL3103X1-LS1
EJA210E-JMS4G-919E
KL2001X1-BB1
CE4036P2
3051TG3A
KJ2221
SPIIT1
5X00499G01
1X01046H01L
MDO53
T5L12-3000
1X01177H01
CE5137
KJ2201X1-BA1
3051CD3A
KL2101X1
EJA530E-DCS9N-010NN
369B1841G0130
SE5009
SPNIS21
369B1844G50
3051S2CD1A
SLS1508
5X00225G01
5A26458G08

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000