o module original new-0

ABB

Home >  Products >  ABB

ABB AC500 S500 DA502 Digital and Analog I/O Module | Original New

ABB AC500 S500
DA502
Combined digital and analog input/output module for distributed AC500 control systems.
KEY SPEC: 16 digital outputs; 8 configurable digital I/O; 4 analog inputs; 2 analog outputs; 50 kHz counter.
LEAD TIME: In stock    WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • I/O Functions
  • Electrical Data
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
ABB AC500 S500 DA502
Combined Digital and Analog Input/Output Module
DA502 combines digital outputs, configurable digital I/O and analog measurement and control channels in one AC500/S500 module. It is intended for compact applications that require mixed field signals without separate digital and analog modules.
Digital Resources
The module provides 16 dedicated 24 V DC transistor outputs plus eight configurable 24 V DC digital I/O points. Each digital output is rated to a maximum of 0.5 A.
Analog Measurement and Control
Four analog inputs support voltage, current and RTD signals with 12-bit-plus-sign resolution. Two analog outputs provide configurable voltage or current control signals.
Ranges and Performance
Input ranges include 0 to 10 V, -10 to +10 V, 0 to 20 mA, 4 to 20 mA, Pt100, Pt1000 and Ni1000. Typical analog error is 0.5%, with a 1 ms analog conversion cycle.
Electrical and Load Data
Supply is 24 V DC with maximum 5% ripple. Outputs O0 to O15 are limited to 4 A total, while configurable points DC16 to DC23 form a separate 4 A group.
Mechanical Integration
DA502 installs on a TU515 or TU516 terminal unit using a 35 mm DIN rail. The assembled envelope is approximately 67.5 x 135 x 84.5 mm and module weight is about 125 g.
Protection and Selection
The IP20 module operates from 0 to 60 °C horizontally or 0 to 40 °C vertically with derating. Confirm DA502 and order number 1SAP250800R0001 before procurement.

Technical Data

Complete model
DA502
Order number
1SAP250800R0001
Product family
ABB AC500 / S500 I/O
Product type
Digital and analog input/output module
Digital outputs
16 x 24 V DC transistor outputs, maximum 0.5 A each
Configurable digital I/O
8 x 24 V DC points, maximum 0.5 A each
Analog inputs
4 channels for voltage, current or RTD; 12 bits plus sign
Analog outputs
2 voltage or current channels; 12 bits plus sign
Analog input ranges
0 to 10 V, -10 to +10 V, 0 to 20 mA, 4 to 20 mA, Pt100, Pt1000 or Ni1000
Analog cycle time
1 ms for four inputs and two outputs; RTD cycle 1 s
Analog accuracy
Typical 0.5%; maximum 1%
Fast counter
Maximum 50 kHz
Supply voltage
24 V DC; maximum ripple 5%
Bus current
Approximately 2 mA
Process supply current
0.07 A plus maximum 0.5 A per active output
Output group current
O0 to O15 maximum 4 A; DC16 to DC23 maximum 4 A
Power dissipation
6 W maximum, unloaded
Terminal unit
TU515 or TU516
Dimensions
Approximately 67.5 x 135 x 84.5 mm, assembled with terminal unit
Weight
Approximately 125 g, without terminal unit
Protection rating
IP20
Operating temperature
0 to 60 °C horizontal; 0 to 40 °C vertical with derating
Storage temperature
-40 to 70 °C

I/O Functions

Digital resources
DA502 provides 16 dedicated 24 V DC transistor outputs and 8 additional configurable 24 V DC digital I/O points.
Analog measurement
Four analog inputs accept voltage, current and RTD signals with 12-bit-plus-sign conversion.
Analog control
Two 12-bit-plus-sign analog outputs support voltage or current actuation, while the integrated fast counter operates to 50 kHz.

Electrical Data

Power system
The module uses 24 V DC process power with maximum 5% ripple and ABB specifies a 10 A fast external fuse.
Digital load groups
Outputs O0 to O15 are limited to 4 A total, and configurable points DC16 to DC23 form a separate 4 A group.
Analog performance
The four analog inputs and two outputs complete a conversion cycle in 1 ms; RTD measurement uses a 1 s cycle. Typical analog error is 0.5%.

Installation

Field termination
DA502 mounts on a TU515 or TU516 terminal unit, which carries the I/O bus and field wiring connections.
Rail installation
Install the assembled unit on a 35 mm DIN rail and keep the documented 20 mm spacing for ventilation and wiring.
Signal segregation
Route analog and digital wiring according to ABB EMC guidance; apply the specified shielding and grounding for low-level analog signals.

Environment

Control cabinet use
The IP20 module must operate inside a suitable enclosure that protects it from conductive contamination and direct contact.
Temperature limits
Horizontal operation is specified from 0 to 60 °C. Vertical installation is limited to 0 to 40 °C with output-group derating.
Storage range
ABB specifies -40 to 70 °C for storage and transport and up to 95% relative humidity without condensation.

FAQ

1. How can purchasing confirm the full DA502 identification?
Require label images showing DA502 and order number 1SAP250800R0001. Confirm the combination of 16 digital outputs, 8 configurable digital I/O, 4 analog inputs and 2 analog outputs.
2. How are new and refurbished DA502 modules distinguished?
Inspect dated photos of the terminal contacts, rail latch, analog connector area and housing. Wiring impressions, scratches, dust or component rework indicate previous service.
3. What makes a DA502 supplier verifiable?
Validate its registered company record, physical address, traceable quotation, beneficiary details and ability to show the exact DA502 label and serial evidence.
4. Which DA502 specifications must an engineer review?
Check 24 V DC supply, digital group current limits, required analog ranges, 12-bit-plus-sign conversion, RTD support, 50 kHz counter needs and TU515 or TU516 compatibility.
5. Which physical records should be obtained before payment?
Request current full-label photos, connector and terminal close-ups, packaging images and a video or functional evidence covering analog and digital channels when agreed.
6. Can DA501 or another DA-series part replace DA502?
A similar code is not automatically interchangeable. Digital channel allocation, analog ranges, counter resources and terminal mapping must be compared and approved by engineering.

Recommend Models

6ES7215-1AF40-0XB0
CC-TCF912
TU844
6ES7288-3AE04-0AA0
CC-TAIX01
VE3051C0
ADV142
6ED1052-2FB08-0BA2
6ES7288-1SR60-0AA1
TU515
6GK7243-5DX30-0XE0
AFV10S
PM5072-R-ETH
6ES7531-7PF00-0AB0
6GK7242-7KX30-0XE0
CI871K01
6ES7517-3HP00-0AB0
AO815
ATK4A
AAV141
6ES7288-3AT08-0AA0
6ES7522-1FH00-0AA0
DO810
6ED1055-1MD00-0BA2
KJ4002X1-CA1
6ED1055-1MA00-0BA2
1756-L85EP
6ED1052-1FB08-0BA1
AAP149
ASI133
KJ1501X1-BC2
SD834
CC-GAOX21
6ES7405-0DA02-0AA0
1756-L61
ATD5A
6GK7242-5DX30-0XE0
TU532
TB852
6ES7288-7ST40-0AA0
6ES7288-1ST20-0AA1
AKB331
TU835
1769-L18ERM-BB1B
KJ3002X1-BD1
6ED1055-1CB00-0BA2
1756-PB75
6ES7517-3AP00-0AB0
VE3051C4
1756-OF8
TU833
6ES7288-3AQ02-0AA0
KJ3002X1-BC1
6ES7416-3FS07-0AB0
VE3012
VE3051C3
6ES7407-0KR02-0AA0
6ES7522-1BH10-0AA0
6ES7332-5HF00-0AB0
CC-PAIX01

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000