allen bradley compactlogix 5370 l1 1769 l18erm bb1b 512 kb motion controller original new-0

ROCKWELL

Home >  Products >  ROCKWELL

Allen-Bradley CompactLogix 5370 L1 1769-L18ERM-BB1B 512 KB Motion Controller | Original New

ALLEN-BRADLEY | CompactLogix 5370 L1
1769-L18ERM-BB1B
CompactLogix L18 512 KB Motion Controller
KEY CONFIGURATION
512 KB user memory | 16 sinking digital inputs | 16 sourcing digital outputs | 2 EtherNet/IP DLR ports | up to 8 EtherNet/IP nodes | 2-axis integrated motion
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Features
  • Interfaces
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Official Identification
Allen-Bradley CompactLogix 5370 L1 1769-L18ERM-BB1B. CompactLogix L18 controller with embedded digital I/O and integrated motion.
Exact Configuration
512 KB user memory | 16 sinking digital inputs | 16 sourcing digital outputs | 2 EtherNet/IP DLR ports | up to 8 EtherNet/IP nodes | 2-axis integrated motion
Engineering Reference
Dimensions: 100 x 130 x 105 mm (W x H x D). Approximate weight: 0.66 kg (1.5 lb). Series B; lifecycle status: Active.
Official Documentation
Rockwell Automation product profile 1769-PP012A-EN-E, pages 1-2; the exact controller selection table is on page 2. Open official PDF

Technical Data

Complete model
1769-L18ERM-BB1B
Product family
CompactLogix 5370 L1
Product type
CompactLogix L18 motion controller with embedded digital I/O
Dimensions
100 x 130 x 105 mm (W x H x D)
Weight
0.66 kg (1.5 lb) approximate
Supply voltage
24 V DC only
User memory
512 KB (0.5 MB)
Local expansion
Up to 8 POINT I/O modules
Embedded inputs
16 sinking digital inputs
Embedded outputs
16 sourcing digital outputs
Ethernet interfaces
2 EtherNet/IP ports with Device Level Ring capability
EtherNet/IP nodes
Up to 8
Integrated motion
2-axis CIP motion position loop
Virtual axes
100
Supported motion drives
Up to 8 feedback, torque, velocity or V/Hz drives
Backplane
POINT Bus
Removable storage
1 GB SD card supplied
Series
B
Lifecycle status
Active
Certifications
Australian RCM; CE; ABS; RINA; Korean KC; UL Listed Hazardous Locations; China CCC; UL Listed; ODVA; ATEX

Features

Compact Control Platform
Combines controller processing, embedded digital I/O and POINT I/O expansion in one CompactLogix 5370 L1 platform. The 512 KB memory supports deterministic machine-control applications.
Integrated Motion
Provides two axes of CIP Motion position-loop control and supports up to eight motion drives. Kinetix integration can be engineered through the EtherNet/IP network.
Embedded I/O
Includes 16 sinking digital inputs and 16 sourcing digital outputs for direct machine signal connection. Up to eight POINT I/O modules can extend the local system.
Removable Storage
A 1 GB SD card is supplied for program storage, backup and restore workflows. The removable medium supports controlled commissioning and maintenance.

Interfaces

EtherNet/IP Network
Two embedded EtherNet/IP ports support Device Level Ring topologies and controller communications. The controller supports up to eight EtherNet/IP nodes.
Digital Inputs
Sixteen 24 V DC sinking inputs connect discrete field devices. Engineers should confirm field voltage, common wiring and input type before commissioning.
Digital Outputs
Sixteen 24 V DC sourcing outputs provide embedded discrete control. Output loading and external protection must match the connected devices.
POINT Bus and SD
The POINT Bus backplane supports local I/O expansion, while the removable SD card supports application transfer and recovery. Both interfaces are part of the exact L1 configuration.

Installation

Panel Planning
Allow space for the 100 x 130 x 105 mm controller and connected POINT I/O modules. Keep wiring ducts and service access clear around the controller.
Power and Grounding
Use the specified 24 V DC supply and apply industrial grounding practices. Verify supply capacity for the controller, embedded I/O and the complete expansion assembly.
Network Topology
Connect the two Ethernet ports according to the selected linear or DLR architecture. Assign addresses and validate the eight-node design limit before startup.
Commissioning Check
Confirm Series B hardware, 512 KB memory, embedded 16 DI and 16 DO, two-axis motion and the full catalog number before loading the application.

Environment

Enclosure Use
Install the controller inside a suitable industrial enclosure and protect it from conductive contamination. Maintain the clearances specified for the assembled POINT I/O station.
Thermal Design
Provide ventilation appropriate to the controller and adjoining modules. Consider heat from the 24 V DC supply, output loads and neighboring equipment.
Network Resilience
Use the two DLR-capable ports only within a validated EtherNet/IP topology. Cable routing and shielding should minimize electrical noise near motor and power conductors.
Certification Scope
The official product page lists RCM, CE, ABS, RINA, KC, UL, CCC, ODVA and ATEX approvals. The delivered unit marking and installation conditions must match the required jurisdiction.

FAQ

Q1. How can I verify that the quotation is for the exact 1769-L18ERM-BB1B?
A. Match the complete catalog number, Series B marking, 512 KB memory, 16 sinking inputs, 16 sourcing outputs, two DLR Ethernet ports and two-axis motion capability against the label and Rockwell Automation documentation.
Q2. How can I distinguish a new unit from used or refurbished stock?
A. Request current photos of the label, Ethernet ports, POINT Bus connector, digital I/O terminals, SD card area and packaging seals. Look for wear, dust, scratched terminals, missing accessories or inconsistent serial information.
Q3. How can I assess whether the supplier is legitimate and reliable?
A. Verify the legal company name, business registration, physical address, payment beneficiary and traceable quotation for 1769-L18ERM-BB1B. Ask for verifiable serial and label evidence before payment.
Q4. Which engineering points should be checked before purchase?
A. Confirm 24 V DC supply, 100 x 130 x 105 mm dimensions, 0.66 kg weight, 512 KB memory, embedded 16 DI and 16 DO, eight-node limit, eight POINT I/O expansion limit and two-axis motion requirement.
Q5. What physical evidence should be requested before payment?
A. Ask for timestamped photos or video showing the exact catalog label, Series B, connector condition, both Ethernet ports, embedded I/O terminals, SD card area and sealed packaging. The evidence should be tied to the quotation.
Q6. Can a similar suffix or another L1 controller replace 1769-L18ERM-BB1B?
A. Not automatically. Differences in memory, embedded I/O, Ethernet node limit, POINT I/O capacity and integrated motion can change the application. Use an alternative only after the hardware configuration and project are formally reviewed.

Recommend Models

FCM2F4
3HAC029896-001
RH916FN
EPRO MMS6310
Tricon 3008
Yokogawa AAI143-H50/K4A00
IMDSO14
DS200SDCCG1A
5466-315
5466-316
1783-BMS10CGP
EPRO MMS6312
B 1C31181G02 Remote I/O Module
X-CPU 01
6 ACS355-03E-15A6-4
ProSoft MVI69E-MBS
3HAC058993-004
IC693MDL742
T8461C
160-BA04NSF1
2707-M485P3
A 5X00419G02 Ethernet Link Controller
AI880A
CC-PDIH01
3HAC058612-00
80190-480-01-R
Emerson A6312
80190-220-01-R
2711R-T10T
Emerson PR9268-301-100
CC-PUIO31
1C31122G02/1C31125G2
TRICONEX 3636R
5466-1141
22B-B012N104
ProSoft RLX2-IHNF-A
IC695CPU315
IEMMU21
1769-L23E-QBFC1B
VersaMax CPU IC200CPUE05
5466-1045
INIIT13
X-PS 01
T8151C
F3316
X20SI4100
3HAC023020-003
MVME147-012
5466-1245
MPC4 200-510-074-113
MVME167-032A
IOCN 200-566-101-012
Yokogawa S2MMM843-SS1130
B 5X00453G01 Remote I/O Node Controller
RH928CY
T8850C
Siemens 6ES7513-1RL00-0AB0
MVME61006E-0161
22B-D6P0N104
DS3800NDAC1B1C

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000