Complete model
|
1756-IR6I
|
|
Brand
|
Allen-Bradley / Rockwell Automation
|
|
Product family
|
ControlLogix 1756
|
|
Product type
|
Individually isolated RTD analog input module
|
|
Inputs
|
6 individually isolated RTD channels
|
|
Input ranges
|
1-487 Ohm, 2-1000 Ohm, 4-2000 Ohm and 8-4000 Ohm
|
|
Resolution
|
16 bits; 7.7, 15, 30 or 60 mOhm/bit according to selected range
|
|
Supported sensors
|
Platinum 385 and 3916; Nickel 618 and 672; Copper 10 Ohm
|
|
Current draw at 5.1 V
|
250 mA
|
|
Current draw at 24 V
|
125 mA
|
|
Total backplane power
|
4.25 W
|
|
Power dissipation
|
4.3 W maximum
|
|
Open-circuit detection
|
Full-scale indication within 5 seconds according to the lost-wire condition
|
|
Overvoltage protection
|
24 VAC/DC maximum
|
|
Channel bandwidth
|
15 Hz, notch-filter dependent
|
|
Settling time
|
Less than 80 ms to 5 percent of full scale
|
|
Calibrated accuracy at 25 degrees C
|
Better than 0.1 percent of range
|
|
Isolation voltage
|
250 V continuous, channels-to-backplane and channel-to-channel
|
|
Removable terminal block
|
1756-TBNH or 1756-TBSH, ordered separately
|
|
Dimensions
|
144.5 x 34.6 x 146.9 mm, height x width x depth
|
|
Weight
|
Approximately 0.2 kg (0.5 lb)
|
|
Slot width
|
One ControlLogix chassis slot
|
|
Enclosure type
|
None, open-style equipment
|
|
Operating temperature
|
0 to 60 degrees C
|
|
Storage temperature
|
-40 to +85 degrees C
|
|
Relative humidity
|
5 to 95 percent, noncondensing
|
|
Lifecycle
|
Discontinued March 31, 2017
|
|
Official sources
|
Rockwell Automation product page; publication 1756-TD002M-EN-E pages 95-100; official drawing ABIOM091; Rockwell ControlLogix 1756 system reference
|
|
Field wiring
|
Use a 1756-TBNH or 1756-TBSH 20-pin removable terminal block housing; order the RTB separately.
|
|
Two-wire connection
|
Short IN-x/B and RTN-x/C together as shown in the official resistor and calibration wiring guidance.
|
|
Three-wire connection
|
Connect IN-x/A, IN-x/B and RTN-x/C and terminate the shield according to the official diagram.
|
|
Four-wire connection
|
Use the published four-wire arrangement and shield grounding while maintaining the 250 V isolation limits.
|
|
I-T-E 2190-E21AA-MOD
|
DIVIP804Kc
|
2CYU4
|
|
G3NA210BUTU
|
K105A04531
|
CPE14-M1BH-3GL-1/8
|
|
58440019
|
7SS5231-5CA01-1AA1
|
3RT2516-1BB40
|
|
1771-WG
|
Notifier ID3000
|
30-8000
|
|
24880RAA2281AX2X1
|
GE DGCC-EHSSABCGXX3XXXX
|
WMZH2D20
|
|
548-49
|
BR2C25UC
|
10-10-05-00
|
|
SZL-VL-SDNM
|
N4006-0500
|
QS-G1/8-6-I
|
|
117442
|
3-038R-R201
|
5201KDD
|
|
193-BSB42
|
M50788
|
ZL-RTB40
|
|
PS5R-VD24
|
Oct-00
|
MAI32LAD 001-1113-05-01
|
|
1794-TB3
|
NFCP502-W15
|
35A-FW-24VAC
|
|
MSP10P
|
7SD5221-5DB99-9HK0
|
777R-017
|
|
BC-ATS-151510
|
1794-ACN15
|
HBL2310SW
|
|
HPA5091-06
|
TLS0406
|
VXZ2230 N-X43
|
|
VB2-PSG 3M-4/2PKG 3M-0.5/0.5/S651 U2-02518
|
FBM242 P0916MU-0A P0916MT
|
A03B-0807-C104 AID16D
|
|
KCP5 871301
|
2945B
|
AID16D A03B-0807-C104
|
|
PRD30-25DN
|
LC1K0910G7
|
2190-WE80-AA
|
|
NLN60
|
MCS20
|
RSE-2111-0600-SHTR-10
|
|
VQ7-6-FIG-D-3ZR
|
E162205-K
|
GE YSILS1B IS220YSILS1BB
|
|
TAPCON260
|
CNMG190612-TH T9025
|