allen bradley controllogix 1756 1756 ir6i 6 point isolated rtd input module-0

ROCKWELL

Home >  Products >  ROCKWELL

Allen-Bradley ControlLogix 1756 1756-IR6I 6-Point Isolated RTD Input Module | Original New

Allen-Bradley ControlLogix 1756 6-Point Isolated RTD Input Module
Complete Model
1756-IR6I
Official Product Description
ControlLogix temperature-sensing analog input module with six individually isolated RTD channels, multiple resistance ranges and 2-wire, 3-wire or 4-wire sensor connections.
CORE FEATURE: Six individually isolated RTD channels with four selectable resistance ranges and broad platinum, nickel and copper sensor support.
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Features
  • Wiring
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
1756-IR6I is an Allen-Bradley ControlLogix 1756 temperature-sensing analog input module with six individually isolated RTD channels.
Rockwell Automation specifies four selectable resistance ranges from 1-487 Ohm through 8-4000 Ohm and 16-bit conversion for supported platinum, nickel and copper RTD sensors.
The module accepts 2-wire, 3-wire and 4-wire field connections through a 20-pin removable terminal block and occupies one ControlLogix chassis slot.

Technical Data

Complete model
1756-IR6I
Brand
Allen-Bradley / Rockwell Automation
Product family
ControlLogix 1756
Product type
Individually isolated RTD analog input module
Inputs
6 individually isolated RTD channels
Input ranges
1-487 Ohm, 2-1000 Ohm, 4-2000 Ohm and 8-4000 Ohm
Resolution
16 bits; 7.7, 15, 30 or 60 mOhm/bit according to selected range
Supported sensors
Platinum 385 and 3916; Nickel 618 and 672; Copper 10 Ohm
Current draw at 5.1 V
250 mA
Current draw at 24 V
125 mA
Total backplane power
4.25 W
Power dissipation
4.3 W maximum
Open-circuit detection
Full-scale indication within 5 seconds according to the lost-wire condition
Overvoltage protection
24 VAC/DC maximum
Channel bandwidth
15 Hz, notch-filter dependent
Settling time
Less than 80 ms to 5 percent of full scale
Calibrated accuracy at 25 degrees C
Better than 0.1 percent of range
Isolation voltage
250 V continuous, channels-to-backplane and channel-to-channel
Removable terminal block
1756-TBNH or 1756-TBSH, ordered separately
Dimensions
144.5 x 34.6 x 146.9 mm, height x width x depth
Weight
Approximately 0.2 kg (0.5 lb)
Slot width
One ControlLogix chassis slot
Enclosure type
None, open-style equipment
Operating temperature
0 to 60 degrees C
Storage temperature
-40 to +85 degrees C
Relative humidity
5 to 95 percent, noncondensing
Lifecycle
Discontinued March 31, 2017
Official sources
Rockwell Automation product page; publication 1756-TD002M-EN-E pages 95-100; official drawing ABIOM091; Rockwell ControlLogix 1756 system reference

Inquiry

Features

Channel-to-channel isolation
All six RTD inputs are individually isolated from one another and from the ControlLogix backplane.
Multiple RTD families
The module supports published platinum, nickel and copper RTD sensor curves.
Four resistance ranges
Select the resistance span and matching 16-bit resolution required by the sensor application.
Wire compensation
Official connection diagrams support 2-wire, 3-wire and 4-wire RTD or resistance measurements.

Wiring

Field wiring
Use a 1756-TBNH or 1756-TBSH 20-pin removable terminal block housing; order the RTB separately.
Two-wire connection
Short IN-x/B and RTN-x/C together as shown in the official resistor and calibration wiring guidance.
Three-wire connection
Connect IN-x/A, IN-x/B and RTN-x/C and terminate the shield according to the official diagram.
Four-wire connection
Use the published four-wire arrangement and shield grounding while maintaining the 250 V isolation limits.

Installation

01 - Verify the complete catalog number
Match 1756-IR6I on the quotation, module label, packaging and Rockwell Automation discontinued-product record.
02 - Confirm the sensor type
Verify the RTD material, coefficient, nominal resistance and required temperature range before selecting the input configuration.
03 - Select the RTB
Choose 1756-TBNH or 1756-TBSH for the 20-pin connection and key the RTB mechanically.
04 - Wire each isolated channel
Follow the exact 2-wire, 3-wire or 4-wire diagram and preserve shield and channel isolation practices.
05 - Configure the range
Set the matching resistance range, data format, notch filter and scaling, then perform the specified calibration checks.

Environment

Operating temperature
0 to 60 degrees C.
Storage temperature
-40 to +85 degrees C.
Relative humidity
5 to 95 percent, noncondensing.
Mechanical endurance
2 g vibration at 10-500 Hz, 30 g operating shock and 50 g nonoperating shock.
Protection
Open-style equipment; install the module in a suitable industrial enclosure.
Certifications
UL, CSA, CE, RCM, ATEX, FM, KC and EAC when marked.
Lifecycle
Discontinued; verify replacement and software migration requirements before purchase.

FAQ

Q1. How can the exact quoted 1756-IR6I be verified?
Match 1756-IR6I on the quotation, module label and packaging. Confirm six individually isolated RTD channels, the four published resistance ranges and the 20-pin 1756-TBNH or 1756-TBSH interface.
Q2. How can New, Used or Refurbished condition be distinguished?
Request date-marked photos of the full label, serial and series markings, CAL and OK indicators, 20-pin RTB connector, backplane connector and housing. Check for terminal wear, changed labels, repaired plastic or residue from prior cabinet installation.
Q3. How should supplier legality and reliability be checked?
Verify the supplier legal entity, registered address, invoice details, payment beneficiary and traceable sales contact. The offer must state Allen-Bradley, 1756-IR6I, discontinued status, condition, quantity and included CJC or RTB accessories if any.
Q4. Which specifications must engineering confirm before purchase?
Confirm the RTD curve and nominal resistance, 1-487 through 8-4000 Ohm range, 2-wire, 3-wire or 4-wire method, 250 V isolation, 1756-TBNH or 1756-TBSH RTB, backplane power, firmware profile and chassis compatibility.
Q5. What physical evidence should be requested before payment?
Ask for date-marked photos showing the full 1756-IR6I label, serial and series markings, six-channel analog input faceplate, RTB connector, backplane edge connector, housing condition and packaging.
Q6. Can 1756-IRT8I or 1756-IR12 replace 1756-IR6I?
Not automatically. They differ in channel count, isolation, supported sensor modes, RTB, resolution and software profile. Complete an engineering and program migration review before any replacement.

Recommend Models

I-T-E 2190-E21AA-MOD
DIVIP804Kc
2CYU4
G3NA210BUTU
K105A04531
CPE14-M1BH-3GL-1/8
58440019
7SS5231-5CA01-1AA1
3RT2516-1BB40
1771-WG
Notifier ID3000
30-8000
24880RAA2281AX2X1
GE DGCC-EHSSABCGXX3XXXX
WMZH2D20
548-49
BR2C25UC
10-10-05-00
SZL-VL-SDNM
N4006-0500
QS-G1/8-6-I
117442
3-038R-R201
5201KDD
193-BSB42
M50788
ZL-RTB40
PS5R-VD24
Oct-00
MAI32LAD 001-1113-05-01
1794-TB3
NFCP502-W15
35A-FW-24VAC
MSP10P
7SD5221-5DB99-9HK0
777R-017
BC-ATS-151510
1794-ACN15
HBL2310SW
HPA5091-06
TLS0406
VXZ2230 N-X43
VB2-PSG 3M-4/2PKG 3M-0.5/0.5/S651 U2-02518
FBM242 P0916MU-0A P0916MT
A03B-0807-C104 AID16D
KCP5 871301
2945B
AID16D A03B-0807-C104
PRD30-25DN
LC1K0910G7
2190-WE80-AA
NLN60
MCS20
RSE-2111-0600-SHTR-10
VQ7-6-FIG-D-3ZR
E162205-K
GE YSILS1B IS220YSILS1BB
TAPCON260
CNMG190612-TH T9025
3G2A3-OA221 SYSMAC-S6

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000