allen bradley controllogix 5570 1756 l73 8mb usb controller-0

ROCKWELL

Home >  Products >  ROCKWELL

Allen-Bradley ControlLogix 5570 1756-L73 8 MB USB Controller

Allen-Bradley ControlLogix 5570 8 MB USB Controller
Complete Model
1756-L73
Official Product Description
ControlLogix 5570 controller with 8 MB user memory, 0.98 MB I/O memory, USB 2.0 local programming and preinstalled Secure Digital storage.
CORE FEATURE: 8 MB ControlLogix 5570 controller with USB programming and Secure Digital nonvolatile storage.
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications & Features
  • Communications
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
1756-L73 is an Allen-Bradley ControlLogix 5570 controller with 8 MB of user memory and 0.98 MB of I/O memory.
Rockwell Automation specifies a USB 2.0 full-speed local programming port, a preinstalled 1 GB 1784-SD1 Secure Digital card and a removable capacitor energy storage module.
The controller occupies one slot in a compatible 1756 ControlLogix chassis and requires separate chassis communication modules for industrial networks.

Technical Data

Complete model
1756-L73
Brand
Allen-Bradley / Rockwell Automation
Product family
ControlLogix 5570
Product type
Chassis-based programmable automation controller
User memory
8 MB
I/O memory
0.98 MB
Nonvolatile memory
1 GB 1784-SD1 Secure Digital card ships preinstalled; larger compatible cards may be available
Local programming port
USB 2.0, full speed at 12 Mbps; temporary local programming only
Embedded network port
None; use separate ControlLogix communication modules
Digital I/O maximum
128,000
Analog I/O maximum
4,000
Energy storage module
1756-ESMCAP removable capacitor module ships installed; 1756-ESMNSE and 1756-ESMNRM are supported options within their stated limits
Current draw
5 mA at 1.2 V DC and 800 mA at 5.1 V DC
Power dissipation
2.5 W
Thermal dissipation
8.5 BTU per hour
Isolation voltage
30 V continuous, basic insulation, USB port to system
Dimensions
Not explicitly stated for 1756-L73 in Rockwell Automation publication 1756-TD001W-EN-P
Weight
Approximately 0.25 kg (0.55 lb)
Slot width
One ControlLogix chassis slot
Enclosure type
None, open-style equipment
Operating temperature
0 to +60 degrees C
Storage temperature
-40 to +85 degrees C
Relative humidity
5 to 95 percent, noncondensing
Vibration
2 g at 10 to 500 Hz
Shock
30 g operating and 50 g nonoperating
Certifications
CE, ATEX, IECEx, Australian RCM, Korean KC, UL and other certifications as marked on the product
Lifecycle
Active Mature on the Rockwell Automation product page
Official source
Rockwell Automation publication 1756-TD001W-EN-P, pages 55 to 57; official 1756-L73 product page

Inquiry

Applications & Features

8 MB user memory
The 1756-L73 doubles the user-memory capacity of the 1756-L72 while retaining the 5570 chassis architecture.
Secure Digital storage
A 1 GB 1784-SD1 card ships preinstalled for nonvolatile project storage.
USB commissioning
The USB 2.0 port supports temporary local programming at 12 Mbps.
Flexible energy storage
The standard removable 1756-ESMCAP can be replaced with supported ESM options for specific security or residual-energy requirements.

Communications

USB programming port
USB 2.0 full-speed port for temporary local programming; do not use as a permanent connection.
ControlLogix backplane
The controller communicates with I/O, power and communication modules through the 1756 chassis backplane.
Industrial networks
Install the required 1756 communication module for EtherNet/IP, ControlNet, DeviceNet or other network protocols.
Secure Digital card
The front card slot supports the preinstalled 1784-SD1 and compatible optional SD cards.
Energy storage module
The installed 1756-ESMCAP provides capacitor-based energy storage without a battery.

Installation

01 - Verify the exact controller
Match 1756-L73 on the quotation, controller label, packaging and Rockwell Automation product record.
02 - Confirm memory capacity
Verify that 8 MB user memory and 0.98 MB I/O memory meet the application requirement.
03 - Prepare the chassis
De-energize the compatible 1756 chassis and reserve one slot with an adequate ControlLogix power supply.
04 - Check storage and ESM
Confirm the SD card and selected energy storage module are installed and compatible with the security requirements.
05 - Commission communication
Use the USB port only for local programming and install separate chassis communication modules for required industrial networks.

Environment

Operating temperature
0 to +60 degrees C.
Storage temperature
-40 to +85 degrees C.
Relative humidity
5 to 95 percent, noncondensing.
Vibration
2 g at 10 to 500 Hz.
Shock
30 g operating and 50 g nonoperating.
Enclosure
Open-style equipment; install the controller and chassis in a suitable industrial enclosure.

FAQ

Q1. How can the exact quoted 1756-L73 be verified?
Match 1756-L73 on the quotation, nameplate and packaging. Confirm ControlLogix 5570, 8 MB user memory, 0.98 MB I/O memory, USB port, SD-card slot and no embedded network port.
Q2. How can New, Used or Refurbished condition be distinguished?
Request date-marked photos of the full label, serial and series markings, USB port, SD-card slot, energy storage module, key switch, display, backplane connector and housing. Check for connector wear, scratches, repaired plastic or altered labels.
Q3. How should supplier legality and reliability be checked?
Verify the supplier legal entity, registered address, payment beneficiary, invoice details and traceable contact. The written offer must identify Allen-Bradley, 1756-L73, condition and quantity.
Q4. Which specifications must engineering confirm before purchase?
Confirm 8 MB user memory, 0.98 MB I/O memory, USB commissioning, SD-card requirements, selected energy storage module, 1756 chassis and power-supply compatibility, firmware and network modules.
Q5. What physical evidence should be requested before payment?
Ask for one date-marked photo set showing the complete 1756-L73 label, serial and series markings, USB port, SD-card area, ESM type, key switch, display, backplane connector, seals and packaging.
Q6. Can 1756-L72, 1756-L74 or 1756-L73S replace 1756-L73?
Not automatically. 1756-L72 has 4 MB, 1756-L74 has 16 MB and 1756-L73S is a safety controller with separate safety memory. Confirm project, safety and exact catalog requirements before substitution.

Recommend Models

CSTVP-0752-CF
8508A-01
H-6600-DP-700-1
VS7-8-FG-D
C.A 6240
ABB PM864AK01 3BSE018161R1
SMB100A
ACQ25X15
NT2-12D
4.4T-10-RSV
D-HC-KA-D
75D73070A
WMZT2D04T
E7012AC002
06137 175MA
RPU1006
3M-1-PSG
CAL5-11
705-12P-24D
3RH21221BB40
RBC-17 H45
753-478
7SJ64 7SJ6411-5EB92-1FE0/EE
GE IS200SCLTH1ABB
HE100THM800B
7SS52 7SS5231-5CA01-0AA1/GG
APW-3 RG33
1522312 SAC-6P-M
BS-49074 R104
BWS496-785
CTS2.5U-N
SKF 6210 2RSJEM
ABB REC670 1MRK004814-AC
82A-BC-000-TM-DAAP-1DA
BFD71S 765A827G01
MI32X50CAG-N
LA9F702
GE VME-7807RC-412000-350-93007807-412000G
E43B015
DT60PW240P
032F1204
140M-F8E-C32
1738-ADN12
4WT46
1492-WM3-BL
DCMT070204-MF2 TP1501
IMx-M 102D
VFS2200-5FZ
CR204XCP11
X-NO-40
VFS4100-5FZ
1.4375-18 UNEF-2A
RD1000
803-001-06M8-13PN
TK-5-1N
TK-E02 TK22EW-X
CKRD2420P
0020-31316
MV-PD-03-0001-01
1397689-0001

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000